On Sun, Oct 22, 2023 at 12:11:19PM +0200, Daniel Smolik wrote:
> Yes no problem. There it is.

Thanks. My best guess is that the problem happens because the region
UUID is visible on both drbd and the lower device, so the global
heartbeat might work if drbd device is selected first (for example in
the case of md).

Since I don't know if it possible to specify the device directly, your
best bet now is probably to use the local heartbeat mode (that should
work without the regions being specified).

-- 
Valentin

Reply via email to