Jorge;

Check the ribbon cable connections going to the front panel. This sounds like 
one of those cables is not connected properly. The chief candidate is the 
40-pin cable on the left side that goes from the Front panel board to the IO 
board.

You should deb able to get the KPA going. If we can’t get you going with it 
today, then be sure to contact tech support tomorrow.

Jack Brindle, W6FB
Elecraft Engineering

On Jun 8, 2014, at 6:40 AM, Jorge Mejia <lauss...@me.com> wrote:

> Hello list members
> 
> I just finished putting together a KPA 500 which seems to be having problems. 
> When I turn  on and try to run the voltage test,  the “HV” button does not 
> respond ….  the led’s bar graph indicate 100 W and I can’t turn it off from 
> the front panel switch,  I have to use the one on the back, neither can I 
> hear the fan discharging the caps. when switched off from the back. Has any 
> of the list members experienced this situation? 
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to jackbrin...@me.com

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to