Hi Jolyon/Patrick,

I increased the times for the following attributes and set the uplink to 
forced-auth.

set dot1x auth-config quietperiod from 3600 to 65535
set dot1x auth-config txperiod from 3600 to 65535
set dot1x auth-config reauthperiod from 3600 to 65535


set dot1x auth-config supptimeout 300 this is the same the highest time.
set dot1x auth-config servertimeout 300 this also the highest value.

Port            : fe.1.25        Station address   : 00-01-e3-23-cf-a6
Auth status     : in progress    Last attempt      : SAT NOV 05 12:31:21 2011
Agent type      : dot1x          Session applied   : false
Server type     : radius         VLAN-Tunnel-Attr  : None
Policy index    : 0              Policy name       : No policy applied
Session timeout : 3610           Session duration  : 0,00:00:00
Idle timeout    : 300            Idle time         : 0,00:00:00
Termination time: Not Terminated


Port            : fe.1.25        Station address   : 00-01-e3-23-cf-a6
Auth status     : success        Last attempt      : SAT NOV 05 12:31:21 2011
Agent type      : mac            Session applied   : true
Server type     : radius         VLAN-Tunnel-Attr  : None
--More-- <space> next page, <cr> one line, <q> quit
Policy index    : 0              Policy name       : No policy applied
Session timeout : 3600           Session duration  : 0,00:26:19
Idle timeout    : 300            Idle time         : 0,00:00:00
Termination time: Not Terminated

However the NIC continues to attempt authentication every 15-30 seconds.

Kind Regards

Pheko Mamabolo
Networks

Siemens Southern Africa
Corporate AFR IT

300 Janadel Avenue, Midrand, 1685
T:   +27(0) 11 652 2938
F:   +27(0) 86 506 6018
M:   +27(0) 82 487 9822
pheko.mamab...@siemens.com
www.siemens.com<http://www.siemens.com>



-----Original Message-----
From: Jolyon Ansuz [mailto:jolyon.an...@une.edu.au]
Sent: 10 November 2011 04:19 AM
To: Enterasys Customer Mailing List
Subject: RE: [enterasys] Help with dot1x reauthentication

Pheko,

On our edge network C-chassis’ we use:

#eapol
set dot1x enable
set dot1x auth-config reauthenabled true reauthperiod 7200 ge.1.1
set dot1x auth-config reauthperiod 14400 ge.1.21

where ge.1.1 is one of many edge ports and where ge.1.21 is an underlying 
member of a LAG that goes to the core network.

We can see this by “show conf eapol”.

This will (read: may) slow your prompts for reauthentication.

You may also need to refer to your N-chassis CLI guide for the correct commands 
and usage.

Sincerely,

Jolyon Ansuz

Senior Network and Communications Administrator
Communications Infrastructure
Information Technology
University of New England
Armidale NSW 2351

P: +61 2 6773 3568
F: +61 2 6773 3424
M: +61 412 735 836

This message contains confidential information and is intended only for the 
individual named. If you are not the named addressee you should not 
disseminate, distribute or copy this e-mail. Please notify the sender 
immediately by e-mail if you have received this e-mail by mistake and delete 
this e-mail from your system.

E-mail transmission cannot be guaranteed to be secure or error-free as 
information could be intercepted, corrupted, lost, destroyed, arrive late or 
incomplete, or contain viruses. The sender therefore does not accept liability 
for any errors or omissions in the contents of this message which arise as a 
result of e-mail transmission. If verification is required please request a 
hard-copy version.

"Most of the things worth doing in the world had been declared impossible 
before they were done.", Louis D. Brandeis




From: Mamabolo, Pheko [mailto:pheko.mamab...@siemens.com]
Sent: Thursday, 10 November 2011 12:30 AM
To: Enterasys Customer Mailing List
Subject: RE: [enterasys] Help with dot1x reauthentication

This is exactly what we are experiencing the re-auth times are between 15 and 
30 seconds.
The firmware is on DFE-G-06.12.08.0003 upgraded today I’d appreciate the work 
around.

Kind Regards

Pheko Mamabolo
Networks

Siemens Southern Africa
Corporate AFR IT

300 Janadel Avenue, Midrand, 1685
T:   +27(0) 11 652 2938
F:   +27(0) 86 506 6018
M:   +27(0) 82 487 9822
pheko.mamab...@siemens.com
www.siemens.com<http://www.siemens.com>

From: Patrick Printz [mailto:ppri...@qcc.mass.edu]
Sent: 09 November 2011 02:54 PM
To: Enterasys Customer Mailing List
Subject: RE:[enterasys] Help with dot1x reauthentication

Pheko,

We dealt with this about a year ago, I was digging and trying to remember what 
we did to fix it. First off, I would make sure the firmware is up-to-date. The 
issue we had though was EAP packets hitting the ports on the switch and causing 
any attached PC’s to re-authenticate. The timing was about every 30 seconds, 
which sounds similar to what you are seeing. Might want to give that a look.

Patrick Printz
Network Infrastructure

Quinsigamond Community College
670 West Boylston Street
Worcester, MA 01606-2092
w. 508-854-7517
c. 508-726-9529


"If a man is called a street sweeper, he should sweep streets even as 
Michelangelo painted, or Beethoven composed music, or Shakespeare wrote poetry. 
 He should sweep streets so well that all the hosts of heaven and Earth will 
pause to say, Here lived a great street sweeper who did his job well."
~Martin Luther King, Jr.

From: Mamabolo, Pheko [mailto:pheko.mamab...@siemens.com]
Sent: Wednesday, November 09, 2011 3:54 AM
To: Enterasys Customer Mailing List
Subject: [enterasys] Help with dot1x reauthentication

Hi

Please advice, we have enabled dot1x on an N3 DFE-G-06.12.08.0003

The NIC keeps reseting as the pics below, any remedy to this as we has set 
re-auth to be false yet this continues.
A minute later


Kind Regards

Pheko Mamabolo
Networks

Siemens Southern Africa
Corporate AFR IT

300 Janadel Avenue, Midrand, 1685
T:   +27(0) 11 652 2938
F:   +27(0) 86 506 6018
M:   +27(0) 82 487 9822
pheko.mamab...@siemens.com
www.siemens.com<http://www.siemens.com>


________________________________________________________________________________________

Disclaimer and Confidentiality Note

This e-mail communication, its attachments, if any, and any rights attaching to 
it are, unless the context clearly indicates otherwise, the property of Siemens 
Limited. It is confidential, private and intended for the addressee only. If 
you are not the intended recipient and receive this communication in error, you 
are hereby notified that any review, copying, use, discloser or distribution in 
any manner whatsoever is strictly prohibited. Please notify the sender 
immediately that you have received this e-mail in error and delete the e-mail 
and any copies of it. Views and opinions expressed in this e-mail are those of 
the sender unless clearly stated as those of Siemens Limited. Siemens Limited 
accepts no liability for any loss or damage whatsoever, and howsoever incurred 
or suffered resulting or arising from the use of this e-mail communication 
and/or its attachments.

Siemens Limited does not warrant the integrity of this e-mail communication nor 
that it is free of errors, viruses, interception or interference.
Siemens Limited, its divisions and subsidiary companies (�Siemens�) expressly 
excludes sections 11, 12, and 13 of the Electronic Communications and 
Transactions Act, 25 of 2002 (�the ECT�) in respect of e-contracting.  No data 
message or electronic communication will be recognised as having a legal 
contractual status under the ECT Act.  All agreements concluded by Siemens will 
only be legally binding when reduced to physical writing and physically signed 
by a duly authorised representative of Siemens.


For more information about Siemens Limited, visit our website at 
www.siemens.com<http://www.siemens.com>

Siemens Limited
Company Registration Number: 1923/007514/06
Registered Address: 300 Janadel Avenue, Halfway House 1685
VAT Registration Number: 4790104428
Chairman:  Dr S Russwurm*
Chief Executive Officer: SG Proebstl*; Chief Financial Officer: AD Hall
Executive Director: AM Mathole
Non-Executive Directors: R Guntermann*; Dr MI Surve; K Setzin
Alternate Directors: I Amod; Y Mahomed
Company Secretary: V Reddy
                                                                                
                *German
• --To unsubscribe from enterasys, send email to lists...@unc.edu with the 
body: unsubscribe enterasys ppri...@qcc.mass.edu
• --To unsubscribe from enterasys, send email to lists...@unc.edu with the 
body: unsubscribe enterasys pheko.mamab...@siemens.com
• --To unsubscribe from enterasys, send email to lists...@unc.edu with the 
body: unsubscribe enterasys jolyon.an...@une.edu.au

---
To unsubscribe from enterasys, send email to lists...@unc.edu with the body: 