I've just found out that PARMLIB(CLOCKxx) here specifies;

   TIMEZONE E.01.01.00

Something to do with synchronising with SVN and Jenkin apparently. Didn't
think I'd need to code for ad-hoc tweaks like that.

Sorry to waste your time.

Steve

-----Original Message-----
From: Steve Austin [mailto:steve.aus...@macro4.com]
Sent: Monday, May 10, 2021 9:22 AM
To: 'IBM Mainframe Discussion List' <IBM-MAIN@LISTSERV.UA.EDU>
Subject: RE: STIMERM LT value

I've run the test twice more specifying a time of 9 o'clock, the 1st with
a STIMERM and an LT=value and the 2nd a GMT=value.  Below are the results
and an extract of the CVT showing CVTLDTO and CVTLSO. Is the value in
CVTLDTO correct?

Thanks

Steve

STCKE following STIMERM specifying GMT=: 08000013 45870000 05102021
00000000
STCKE following STIMERM specifying LT=:  07590001 76150000 05102021
00000000

EXT2: 00FD9168
   +0004  NUCLS.... F1        FLGBT.... 10        IOCID.... F2F5
   +0008  DEBVR.... 00FDF208  CVAF..... 00C24000  MMVT..... 00FD5880
   +0014  NCVP..... 00000000  QIDA..... 000000    OLTEP.... 00000000
   +0024  AVVT..... 80000000  CCVT..... 00000000  SKTA..... 00000000
   +0030  ICB...... 00000000  FBYT1.... 00
   +0038  LDTO..... 00000DA2  72B00000            ATCVT.... 80BFC000
   +0048  BCLMT.... 00000064  LSO...... 00000000  00000000


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
Behalf Of Peter Relson
Sent: Sunday, May 9, 2021 2:53 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: STIMERM LT value

Perhaps the OP should try using GMT=  instead of LT=, to see just how
things work without the time zone offset coming into play.
Is it still off by a minute when using GMT= ?

Peter Relson
z/OS Core Technology Design


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

-- 
This e-mail message has been scanned and cleared by Google Message Security 
and the UNICOM Global security systems. This message is for the named 
person's use only. If you receive this message in error, please delete it 
and notify the sender. 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to