https://issues.apache.org/jira/browse/FLINK-32023?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Rui Fan updated FLINK-32023:
----------------------------
    Affects Version/s: 1.16.1
                       1.17.0
                       1.18.0
           Issue Type: Bug  (was: Improvement)

> execution.buffer-timeout cannot be set to -1 ms
> -----------------------------------------------
>
>                 Key: FLINK-32023
>                 URL: https://issues.apache.org/jira/browse/FLINK-32023
>             Project: Flink
>          Issue Type: Bug
>          Components: API / DataStream
>    Affects Versions: 1.17.0, 1.16.1, 1.18.0
>            Reporter: Liu
>            Priority: Major
>
> The desc for execution.buffer-timeout is as following:
> {code:java}
> public static final ConfigOption<Duration> BUFFER_TIMEOUT =
>         ConfigOptions.key("execution.buffer-timeout")
>                 .durationType()
>                 .defaultValue(Duration.ofMillis(100))
>                 .withDescription(
>                         Description.builder()
>                                 .text(
>                                         "The maximum time frequency 
> (milliseconds) for the flushing of the output buffers. By default "
>                                                 + "the output buffers flush 
> frequently to provide low latency and to aid smooth developer "
>                                                 + "experience. Setting the 
> parameter can result in three logical modes:")
>                                 .list(
>                                         text(
>                                                 "A positive value triggers 
> flushing periodically by that interval"),
>                                         text(
>                                                 FLUSH_AFTER_EVERY_RECORD
>                                                         + " triggers flushing 
> after every record thus minimizing latency"),
>                                         text(
>                                                 
> DISABLED_NETWORK_BUFFER_TIMEOUT
>                                                         + " ms triggers 
> flushing only when the output buffer is full thus maximizing "
>                                                         + "throughput"))
>                                 .build()); {code}
> When we set execution.buffer-timeout to -1 ms, the following error is 
> reported:
> {code:java}
> Caused by: java.lang.IllegalArgumentException: Could not parse value '-1 ms' 
> for key 'execution.buffer-timeout'.
>     at 
> org.apache.flink.configuration.Configuration.getOptional(Configuration.java:856)
>     at 
> org.apache.flink.streaming.api.environment.StreamExecutionEnvironment.configure(StreamExecutionEnvironment.java:822)
>     at 
> org.apache.flink.streaming.api.environment.StreamExecutionEnvironment.<init>(StreamExecutionEnvironment.java:224)
>     at 
> org.apache.flink.streaming.api.environment.StreamContextEnvironment.<init>(StreamContextEnvironment.java:51)
>     at 
> org.apache.flink.streaming.api.environment.StreamExecutionEnvironment.createStreamExecutionEnvironment(StreamExecutionEnvironment.java:1996)
>     at java.util.Optional.orElseGet(Optional.java:267)
>     at 
> org.apache.flink.streaming.api.environment.StreamExecutionEnvironment.getExecutionEnvironment(StreamExecutionEnvironment.java:1986)
>     at com.kuaishou.flink.examples.api.WordCount.main(WordCount.java:27)
>     at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
>     at 
> sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:62)
>     at 
> sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)
>     at java.lang.reflect.Method.invoke(Method.java:498)
>     at 
> org.apache.flink.client.program.PackagedProgram.callMainMethod(PackagedProgram.java:327)
>     ... 11 more
> Caused by: java.lang.NumberFormatException: text does not start with a number
>     at org.apache.flink.util.TimeUtils.parseDuration(TimeUtils.java:78)
>     at 
> org.apache.flink.configuration.Configuration.convertToDuration(Configuration.java:1058)
>     at 
> org.apache.flink.configuration.Configuration.convertValue(Configuration.java:996)
>     at 
> org.apache.flink.configuration.Configuration.lambda$getOptional$2(Configuration.java:853)
>     at java.util.Optional.map(Optional.java:215)
>     at 
> org.apache.flink.configuration.Configuration.getOptional(Configuration.java:853)
>     ... 23 more {code}
> The reason is that the value for Duration can not be negative. We should 
> change the behavior or support to trigger flushing only when the output 
> buffer is full.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to