Hi John,
ons 2006-07-26 klockan 01:07 -0500 skrev John H.:
> is generic driver only for serial?
> 
Yes it is only to be run on a communication port.
It uses contact closure signaling. Look at the contact-closure.txt
in the docs directory.

In the driver list it say
"Powerware"     "3110"          ""      "genericups upstype=7"

Read the manpage for genericups. In the ups.conf you need to set
upstype=7

8<-----snip-----

Regards
Kjell



_______________________________________________
Nut-upsuser mailing list
Nut-upsuser@lists.alioth.debian.org
http://lists.alioth.debian.org/mailman/listinfo/nut-upsuser

Reply via email to