Le Thursday 20 January 2011 20:35:32 Adrian Glaubitz, vous avez ?crit : > Hi Stef, > > On Jan 20, 2011, at 7:01 AM, stef wrote: > > I have just updated the genesys backend to include the 100 dpi scan > > > > patch. I have also cleaned up the resolution list and internal values > > matching them so that no more modes give 'invalid argument' error. What > > is left to do is to tuned thes internal values (like for the 100 dpi > > chnage) to have them all working. > > That's nice, thank you. > > I will try to find time to play around with the parameters of the remaining > resolutions again. Maybe I can figure out the proper values for these > resolutions as well. > > Do you have any ideas or hints which might help finding the proper values? > > Adrian
Hello, the way I do this is to record USB activity while doing a scan under windows, then decode this log with the appended scripts. Unpacked them in a directory. They are run through the decode.sh shell script. Regards, Stef -------------- next part -------------- A non-text attachment was scrubbed... Name: scripts.tar.gz Type: application/x-compressed-tar Size: 14589 bytes Desc: not available URL: <http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110120/5461e3a4/attachment-0001.bin>