Well, according to the debug message, this model is untested. Perhaps you can email the author as directed?
allan On Fri, Jul 22, 2011 at 7:40 AM, Werner Randelshofer <werner.randelshofer at bluewin.ch> wrote: > Hi Allan, > > I have now disabled agfafocus and enabled microtek. > scanimage -L works now. This is great. Thank you! > > Unfortunately, I still can not scan a page. I get the following error message. > > scanimage: sane_start: Error during device I/O > > I have attached the output of scanimage at the end of this e-mail. > I have switched the debugging on for sanei_scsi and microtek. > > I guess there might be a problem with the commands that are sent to the > device. > Suggestions highly appreciated. > > Werner > > > On 22.07.2011, at 12:51, m. allan noah wrote: >> Try changing /etc/sane.d/dll.conf. Disable agfafocus and make sure >> microtek is enabled. >> >> allan > > > $ scanimage > Desktop/test.pnm > [sanei_debug] Setting debug level of microtek to 128. > [microtek] sane_init: ?MICROTEK says hello! (v0.13.1) > [microtek] sane_init: ?config-> # Uncomment following line to disable "real > calibration" routines... > [microtek] sane_init: ?config-> #norealcal > [microtek] sane_init: ?config-> # Uncomment following line to disable "clever > precalibration" routines... > [microtek] sane_init: ?config-> #noprecal > [microtek] sane_init: ?config-> # ? Using "norealcal" will revert backend to > pre-0.11.0 calibration code. > [microtek] sane_init: ?config-> scsi * * Scanner > [microtek] attach_scanner: ?<019bc800000000172dcdf573> > [microtek] attach_scanner: ?opening <019bc800000000172dcdf573> > [sanei_debug] Setting debug level of sanei_scsi to 255. > [microtek] attach_scanner: ?sending INQUIRY > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:96 isWrite:0 > [sanei_scsi] isRead dst_size:96 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 96 bytes > [microtek] id_microtek... > [microtek] > [microtek] > [microtek] > [microtek] ========== Congratulations! ========== > [microtek] Your scanner appears to be supported > [microtek] by the microtek backend. ?However, it > [microtek] has never been tried before, and some > [microtek] parameters are bound to be wrong. > [microtek] > [microtek] Please send the scanner inquiry log in > [microtek] its entirety to mtek-bugs at mir.com and > [microtek] include a description of the scanner, > [microtek] including the base optical resolution. > [microtek] > [microtek] You'll find complete instructions for > [microtek] submitting an error/debug log in the > [microtek] 'sane-microtek' man-page. > [microtek] > [microtek] > [microtek] > [microtek] ?=== SANE/Microtek backend v0.13.1 === > [microtek] ========== Scanner Inquiry Block ========mm > [microtek] 06 00 01 01 5b 00 00 00 41 47 46 41 20 20 20 20 > [microtek] 44 55 4f 53 43 41 4e 20 20 20 20 20 20 20 20 20 > [microtek] 32 2e 33 30 53 43 53 49 20 46 57 20 56 33 2e 36 > [microtek] 20 43 54 4c 35 33 38 30 03 4f 8c c5 06 ee 5d 43 > [microtek] 01 03 47 00 00 83 00 01 0e 4a 07 05 00 00 00 00 > [microtek] 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ff > [microtek] ========== Scanner Inquiry Report ========== > [microtek] ===== Scanner ID... > [microtek] Device Type Code: 0x06 > [microtek] Model Code: 0x5d > [microtek] Vendor Name: 'AGFA ? ?' ? Model Name: 'DUOSCAN ? ? ? ? ' > [microtek] Vendor Specific String: 'SCSI FW V3.6 CTL5380' > [microtek] Firmware Rev: '2.30' > [microtek] SCSI F/W version: 0.0 ? ? Scanner F/W version: 0.1 > [microtek] Response data format: 0x01 > [microtek] ===== Imaging Capabilities... > [microtek] Modes: ?Lineart Halftone Gray Color (OnePass) > [microtek] Resolution Step Sizes: 1% 5% ? ?Expanded Resolution Support? yes > [microtek] Supported Bits Per Sample: 4 8 10 12 > [microtek] Max. document size code: 0x06 > [microtek] Max. document size: ?8299 x 13499 pixels > [microtek] Frame units: ?pixels ?1/8"'s > [microtek] # of built-in halftones: 12 ? Downloadable patterns? Yes > [microtek] Data Compression: > [microtek] Contrast Settings: 14 ? Exposure Settings: 74 > [microtek] Adjustable Shadow/Highlight? yes ? Adjustable Midtone? yes > [microtek] Digital brightness/offset? yes > [microtek] Gamma Table Size: 4096 entries of 2 bytes (max. depth: 12) > [microtek] ===== Source Options... > [microtek] Feed type: ?flatbed ? ?ADF support? yes > [microtek] Document Feeder Support? yes ? Feeder Backtracking? yes > [microtek] Feeder Installed? no ? ? ? ? ? Feeder Ready? no > [microtek] Transparency Adapter Installed? yes > [microtek] Fast Color Prescan? no > [microtek] Selectable Transfer Format? no > [microtek] Color Transfer Sequence: line-by-line, non-sequential with headers > [microtek] Three pass scan support? no > [microtek] ModeSelect-1 and ModeSense-1 Support? yes > [microtek] Can Disable Linearization Table? no > [microtek] Can Disable Start-of-Scan Recalibration? no > [microtek] Internal expanded expansion? no > [microtek] ====== End of Scanner Inquiry Report ======= > [sanei_debug] Setting debug level of sanei_scsi to 255. > [sanei_scsi] sanei_scsi_open: device name /dev/scanner is not valid > [sanei_debug] Setting debug level of sanei_scsi to 255. > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:0 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:9 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:9 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 9 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:0 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes > [sanei_scsi] cmd2: cmd_size:10 src_size:8192 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:8192 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 8192 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:11 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:11 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 11 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:10 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:10 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 10 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:0 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:0 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:6 isWrite:0 > [sanei_scsi] isRead dst_size:6 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 6 bytes > [sanei_scsi] taskStatus = 0x00000002 > [sanei_scsi] cmd2: cmd_size:6 src_size:0 dst_size:0 isWrite:1 > [sanei_scsi] isWrite src_size:0 > [sanei_scsi] Executing command > [sanei_scsi] ExecuteTaskSync OK Transferred 0 bytes > scanimage: sane_start: Error during device I/O > > > -- "The truth is an offense, but not a sin"