On Fri, 23 Sep 2016 10:40:35 +0200 (CEST)
Johannes Meixner <jsm...@suse.de> wrote:

> Hello,
> 
> On Sep 22 18:33 rhn wrote (excerpt):
> > the scanner I am using has a peculiar problem, where scanning
> > consecutive images causes the image quality to degrade:
> > the left part becomes yellow in vertical streaks that increase
> > in numbers; the right part becomes red. To get a completely
> > yellow-red image, about 10 scans are necessary, regardless
> > of options.
> > The backend for this scanner is plustek.  
> 
> at openSUSE we have an issue report with similar symptoms
> but different backend (HP Scanjet 2400, genesys backend):
> 
> https://bugzilla.opensuse.org/show_bug.cgi?id=905034
> 
> I was unable to reproduce it or debug the root cause
> so that all I did was basically blind guess, e.g. see:
> 
> https://bugzilla.opensuse.org/show_bug.cgi?id=905034#c18
> 
> 
> Kind Regards
> Johannes Meixner

Thanks for pointing out that bug report.

I think that my issue might be different. I forgot to mention, but starting a 
new scan (second scanimage command) yields the same results, i.e. first 2 pages 
are fine.

I managed to get the git build to run locally, and I'm testing it, so my 
initial question is answered.

I suspect my hardware is shot and needs extra resets. Is there any other user 
of UT16 that can confirm?

Cheers,
rhn

-- 
sane-devel mailing list: sane-devel@lists.alioth.debian.org
http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/sane-devel
Unsubscribe: Send mail with subject "unsubscribe your_password"
             to sane-devel-requ...@lists.alioth.debian.org