[sane-devel] Epson Perfection 3490, Mandriva 2006.
Showork show...@verizon.net writes: Mandriva OS sees the scanner as Epson flatbed , but does not have the model. The exact model is not listed. libusb:004:005 is reported as the scanner. FWIW, these numbers (may) change whenever you replug or power cycle the device or reboot your machine. What are the permissions on the device? $ ls -l /proc/bus/usb/004/005 This worked a month ago within an hour of bringing it home from the store. Not now because I changed/upgraded the OS. Doh! What does $ SANE_DEBUG_EPKOWA=50 iscan say? You can also try this with xsane or scanimage. If you don't have iscan installed, you can use this device also with the snapscan backend . In that case $ SANE_DEBUG_SNAPSCAN=50 scanimage I had, there was a super a-z guide for this scanner I cant find it :-( . Would you be refering to the user's guide that's downloadable from the same place as the iscan package(s)? http://www.avasys.jp/english/linux_e/dl_scan.html Does anyone have/know of a really good trouble shooting/ installation guide for this scanner.I'd like to be able to select the model in Mandriva 's GUI, how do I get it there? Hope this helps, -- Olaf Meeuwissen EPSON AVASYS Corporation, SE1 FSF Associate Member #1962 sign up at http://member.fsf.org/ GnuPG key: 6BE37D90/AB6B 0D1F 99E7 1BF5 EB97 976A 16C7 F27D 6BE3 7D90 Penguin's lib! -- I hack, therefore I am -- LPIC-2
[sane-devel] Re: CanoScan LiDE20 jamming with scanimage
Second update: I'm now running Knoppix LiveCD, and the scanner works just fine with SANE - scanimage, XSane, and xscanimage (which is absent from my main SANE installation) scan to the end without ever jamming. The scanner makes some strange noises which it doesn't in Windows, but it *works*. But since my main OS is FC5, and I (obviously) can't boot from Knoppix everytime, I absolutely have to get SANE to work on Fedora. Thanks in advance, -Fibo 2006/4/11, Fibonacci Prower fibonacci.pro...@gmail.com: 2006/4/11, Gerhard Jaeger gerh...@gjaeger.de: On Tuesday 11 April 2006 10:14, Fibonacci Prower wrote: Update: I tried with xsane, and... it still jams. And it hasn't yet jammed under Windows. -Fibo 2006/4/5, Fibonacci Prower fibonacci.pro...@gmail.com: Hello, First of all, I have no experience whatsoever with Linux, so I apologise in advance for any stupidity I might have made, or detail I might have omitted. That being said, I can proceed: I have just installed Fedora Core 5 (2.6.15-1.2054_FC5smp), and I'm trying to use the CanoScan LiDE20 scanner which, according to http://www.sane-project.org/sane-mfgs.html, is completely supported by SANE. sane-find-scanner detects it, but it jams (with the lamps on) whenever I try to scanimage, and nothing short of unplugging it from the PC will stop it. I reboot to Windows XP (ahh, the magic of dual-boot), and it scans perfectly well, not jamming at all (which proves that the scanner is working fine). I then reboot to Linux, sane-find-scanner finds it again, and scanimage makes it jam again. Terminating scanimage gives only a Trying to stop scanner message, but the scanner does not stop until I unplug it. Trying to run scanimage again (with the scanner plugged back in, of course) results in scanimage: no SANE devices found, even though sane-find-scanner still sees it. What can I do about this problem? Thank you for your time, -Fibonacci Hi, again my questions: Which SANE version? 1.0.17, apparently. Which XSANE settings to scan? Ehm... the default settings? I didn't touch anything. Preview scan? Yes. 150DPI scan? Haven't yet learnt how to do that. And please don't answer directly to me, use the mailing list. TIA Gerhard -- sane-devel mailing list: sane-devel@lists.alioth.debian.org http://lists.alioth.debian.org/mailman/listinfo/sane-devel Unsubscribe: Send mail with subject unsubscribe your_password to sane-devel-requ...@lists.alioth.debian.org -- Ding dong! The bitch is dead! Which old bitch? The wicked bitch! Ding dong! The wicked bitch is dead! -- Ding dong! The bitch is dead! Which old bitch? The wicked bitch! Ding dong! The wicked bitch is dead! -- next part -- An HTML attachment was scrubbed... URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20060418/f11b1ea2/attachment.htm From panem...@gmail.com Tue Apr 18 03:28:05 2006 From: panem...@gmail.com (=?UTF-8?Q?Parag_N(=E0=A4=AA=E0=A4=B0=E0=A4=BE=E0=A5=9A)?=) Date: Tue Apr 18 03:28:16 2006 Subject: [sane-devel] Canon LiDE 25 is not working In-Reply-To: 1145301666.23016.1.ca...@prix.pricom.com.au References: f4586a2e0604170503x4e210d00h35e431e67d0b0...@mail.gmail.com 1145301666.23016.1.ca...@prix.pricom.com.au Message-ID: f4586a2e0604172028v3a17e740vfe845cabfdd3f...@mail.gmail.com Hi, I didn't get you. When i search archive i found that i need to pass --disable-locking to ./configure command which i did. but still scanimage image.pnm shows blackwhite strips in image. Regards, Parag. On 4/18/06, Philip Rhoades p...@pricom.com.au wrote: Parag, There is a physical locking mechanism (there is on the 20 60 anyway) that you have to turn off before using the scanner - you have done that I presume? Phil. On Mon, 2006-04-17 at 17:33 +0530, Parag N() wrote: hello, Just got Canon LiDE 25 scanner to test it. I then plug it to FC5 system and lsusb shows its usb ids. Then i downloaded today's snapshot from CVS and installed both sane-backend and sane-frontend 1.0.17 version and then used scanimage -L is shows device 'plustek:libusb:002:002' is a Cnon LiDE25 USB flatbed scanner then i used xsane and command line scanimage but in both cases head is making noise and not at all moving but i am getting half left part as balck and halg left part as white image. what is the reason that its not working? I also went thru' some archive and found i need to recompile sane-backend with --disable-locking i did that successfully but still not able to scan a image. Any suggestions... Regards, Parag. -- sane-devel mailing list: sane-devel@lists.alioth.debian.org http://lists.alioth.debian.org/mailman/listinfo/sane-devel Unsubscribe: Send mail with subject unsubscribe your_password to sane
[sane-devel] Live preview while scanning possible? (lide 60)
Hi, On 2006-04-18 08:51, Yuri Pozzi wrote: is possible to view the image creating while scanning on the lide 60 driver? I've used Vuescan and does it, it would be very useful for my needs. The preview itself is continuously updated (at least with the LiDe 50, which I just tested). As far as i know no SANE frontend does the same when doing a real scan. From the SANE api, this is possible as the scanned data is continuously read by the frontend. So it's just that nobody has implemented that feature yet. Another question, if I do BW scans on sane they don't have much depth instead on Vuescan they have much more greys, is this fixed in the last version of sane? I guess this is about gray mode (not lineart)? With the Lide 50 it looks like this for me (xsane, no gamma/brightness/contrast corrections): http://www.meier-geinitz.de/sane/tmp/gray.png I.e. the darkest four blacks look the same. However, I have no comparison how Windows or Vuescan does this. Bye, Henning
[sane-devel] usb_set_interface and usb_claim_interface
Hi, On 2006-04-17 09:07, Tamkang wrote: Does anyone know why the position of usb_set_interface before usb_claim_interface, get return -1 ? As far as I know there is no libusb function called usb_set_interface. If you refer to usb_set_altinterface, you really must claim the interface before. Using an alternative interface is just a different way of using the same interface so it is blocked by the access. because I am trying to developing driver sm3880 for sane-backend, and I got this I/O Device Error, but I got fixed after, I reverse the usb_claim_interface is on behind, after usb_set_interface function got return 0, any one know why? I highly recommend to use the SANEI wrapper functions in sanei/sanei_usb.c for SANE backends instead of using libusb directly. At least with normal USB devices this makes life a little bit easier for you (and us, because it reduces porting issues). So you write a backend for the Microtek Scanmaker 3880? This scanner is not yet in our list. Could you give more details, e.g. the output of sane-find-scanner -v -v and if the scanner uses the same chipset as the 3800 or some other scanner. Bye, Henning
[sane-devel] Canon LiDE 25 is not working
Hi, On 2006-04-18 08:58, Parag N() wrote: I didn't get you. When i search archive i found that i need to pass --disable-locking to ./configure command which i did. but still scanimage image.pnm shows blackwhite strips in image. Some scanners have a hardware lock mechanism. This switch is usually on the bottom side of the scanner. If it's enabled, the scan head can't move. It's intended for transporting the scanner to avoid destroing the scan head. If this mechanism also exists in your scanner and it's enabled the scan head will not move even if SANE tries to move it. Bye, Henning
[sane-devel] Re: CanoScan LiDE20 jamming with scanimage
Hi, On 2006-04-17 22:37, Fibonacci Prower wrote: Third update: I uninstalled all packages whose name contained the string sane, downloaded the sources from ftp://ftp.sane-project.org/pub/sane/ for both frontends and backends, compiled them, installed them, ran xscanimage... And my scanner still jams. Maybe a problem with the USB part of the kernel used by your distribution? If you have a choice, try a different kernel. Bye, Henning
[sane-devel] Canon LiDE 25 is not working
Hi, Thanks for info Henning but i got it already working and able to use it without any problem. Regards, Parag. On 4/18/06, Henning Meier-Geinitz henn...@meier-geinitz.de wrote: Hi, On 2006-04-18 08:58, Parag N() wrote: I didn't get you. When i search archive i found that i need to pass --disable-locking to ./configure command which i did. but still scanimage image.pnm shows blackwhite strips in image. Some scanners have a hardware lock mechanism. This switch is usually on the bottom side of the scanner. If it's enabled, the scan head can't move. It's intended for transporting the scanner to avoid destroing the scan head. If this mechanism also exists in your scanner and it's enabled the scan head will not move even if SANE tries to move it. Bye, Henning -- sane-devel mailing list: sane-devel@lists.alioth.debian.org http://lists.alioth.debian.org/mailman/listinfo/sane-devel Unsubscribe: Send mail with subject unsubscribe your_password to sane-devel-requ...@lists.alioth.debian.org
[sane-devel] Added USB vendor and product ids to all backends, PLEASE CHECK!
Hi everybody, I just committed the last batch of .desc files to CVS. All USB backend .desc files which are included in sane-backends now contain USB vendor and product ids. Some ids are still missing, I'll psot a list later. Backend maintainers: Please check if everything is correct. As I don't know most of the devices, I had to guess the ids from the man pages, config files, web sites and the code itsself. These files were changed today: avision.desc (regenerated with modified version of avision-desc.sh) epson.desc fujitsu.desc hp.desc plustek.desc (also some splitted entries and changed one comment) u12.desc umax.desc Bye, Henning
[sane-devel] saned pnm-backend - glibc detected *** malloc(): memory corruption (fast):
Hello, I'm writing a small client application and use saned. The tests of the client use then pnm-backend. There seems to be a bug in this backend. If I open the first device pnm:0 it's ok. I can read all options of this device. Then I try to open pnm:1. The reply state is device busy - also ok for me. If I now reread the options of pnm:0 there is a error (see subject line). I can get some options, but always the next get-request after option 2 (filename) fails. Maybe the reason is that option 2 is the only String-option. The installed version is sane-backend 1.0.17. regards, Michael -- next part -- A non-text attachment was scrubbed... Name: saned-d128.strace.gz Type: application/x-gunzip Size: 10257 bytes Desc: not available Url : http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20060418/a0f87d85/saned-d128.strace-0001.bin -- next part -- A non-text attachment was scrubbed... Name: saned-d128_4.log.gz Type: application/x-gunzip Size: 1093 bytes Desc: not available Url : http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20060418/a0f87d85/saned-d128_4.log-0001.bin From wy-sane-de...@arcor.de Tue Apr 18 10:43:15 2006 From: wy-sane-de...@arcor.de (Wittawat Yamwong) Date: Tue Apr 18 13:07:13 2006 Subject: [sane-devel] Backend and stand-alone utility for Canon PIXMA MP150/MP170 In-Reply-To: 20060417145519.ga26...@meier-geinitz.de References: 200604160217.58668.wy-sane-de...@arcor.de 20060417145519.ga26...@meier-geinitz.de Message-ID: 200604181243.15122.wy-sane-de...@arcor.de On Monday 17 April 2006 16:55, Henning Meier-Geinitz wrote: Thanks, very nice. I added a pixma.desc file to the SANE CVS so there are links to your backend now: http://www.sane-project.org/lists/sane-backends-external.html#S-PIXMA Feel free to comment on the status levels I used for the scanners. Thank you! The status level (basic) matches the status of my driver. It supports all basic functions of the device but the color output could be better if I implement a color management. It's not ready for everyday use yet because I didn't get any feedbacks from another users. There could be many bugs and compatibility problems. Regards -- Wittawat Yamwong Hannover, Germany
[sane-devel] Mustek/Paragon MFS-8000SP oddity - no gain
Am Montag, 17. April 2006 19:59 schrieb Henning Meier-Geinitz: All configuration files are in /etc/sane.d (or /usr/local/etc/sane.d/). There is no relation to saned. Interesting. Well, anyway, tried the buffer option (2048) and disable-backtracking, no improvement at all. Seems this thing is just slow. -eBay. (Anyone interestes in that device by chance? With controller, active terminator and cables? The image *quality* is great.) -- -BEGIN GEEK CODE BLOCK- Version: 3.12 GCS d--(+)@ s-:+ a- C+++() UL+ P+++ L+++ E-- W++ N o? K- w--(---) !O M+ V- PS++(+) PE(-) Y++ PGP t++(---)@ 5 X+(++) R+(++) tv--(+)@ b++(+++) DI+++ D G++ e* h++ r%* y? --END GEEK CODE BLOCK-- http://www.stop1984.com http://www.againsttcpa.com
[sane-devel] Missing USB vendor and product ids, please help!
Hi everybody! I checked our lists and for the following scanners I can't find the correct USB vendor and product ids. If you own such a device or know the ids, please send them to me. Jsut run sane-find-scanner to find out the id. *** Backends included into the sane-backends distribution: epson.desc (Epson DX-3850) fujitsu.desc (Fujitsu fi-4530C) hp5400.desc (Hewlett-Packard ScanJet 5490c) snapscan.desc (AGFA SnapScan e60) umax.desc (UMAX Astra MX3) *** External backends epkowa.desc (EPSON CC-500L) epkowa.desc (EPSON CC-550L) epkowa.desc (EPSON CC-700) epkowa.desc (EPSON F-3200) epkowa.desc (EPSON GT-7400U) epkowa.desc (EPSON GT-8400UF) epkowa.desc (EPSON Stylus CX1500) viceo.desc (IBM IdeaScan 2000 USB) samsung.desc (Samsung SCX-4016) samsung.desc (Samsung SCX-4720F) samsung.desc (Samsung SCX-6220) samsung.desc (Samsung SCX-6320F) samsung.desc (Samsung SF-565P) samsung.desc (Samsung SF-755P) *** Unsupported scanners: unsupported.desc (Avision iVina FB2400) unsupported.desc (C-Channel MyPen Pro) unsupported.desc (C-Channel MoneyPen II) unsupported.desc (Canon IS 12) unsupported.desc (Canon IS 52) unsupported.desc (Epson ) unsupported.desc (Epson ) unsupported.desc (Fujitsu fi-4110EOX2) unsupported.desc (Hewlett-Packard Photosmart 1200 Photo) unsupported.desc (Lexmark X5150) unsupported.desc (Microtek ArtixScan 4000tf) unsupported.desc (Mustek 2400 M) unsupported.desc (Mustek ScanExpress CardSmart) unsupported.desc (Panasonic KV-S2026C) unsupported.desc (Panasonic KV-S2046C) unsupported.desc (Panasonic KV-S2055W) unsupported.desc (Panasonic KV-S3065CW) unsupported.desc (Panasonic KV-S3065CL) unsupported.desc (Panasonic KV-S3085) unsupported.desc (Panasonic KV-S3105C) unsupported.desc (Panasonic KV-S7065C) unsupported.desc (PIE Primefilm 3600PRO) unsupported.desc (Plustek OpticPro A3U) unsupported.desc (Plustek OpticPro S6) unsupported.desc (Plustek OpticPro UA18) unsupported.desc (Plustek OpticPro ST64) unsupported.desc (Plustek OpticPro ST64+) unsupported.desc (Plustek OptiCard 600+) unsupported.desc (Primax Slim-Line 1200) unsupported.desc (Prolink Winscan Pro 2000) unsupported.desc (Quato X-Finity Ultra) unsupported.desc (SmartDisk SmartScan 3600) unsupported.desc (UMAX Astra 4600) unsupported.desc (UMAX Astra 6700) unsupported.desc (UMAX Powerlook 180) unsupported.desc (UMAX Powerlook 1000 USB) unsupported.desc (Visioneer Onetouch 8900) Bye, Henning
[sane-devel] Preparation for sane-backends release 1.0.18
Hi developers! I intend to start the countdown for the release of sane-backends 1.0.18 in a few weeks. So it's now the right time to include any big changes into sane-backends that are available. Especially big updates of existing backends and new backends should be included in the following weeks. What's the status of the following external backends? Can they be included into sane-backends? Keep in mind that this gives you a much bigger audience and many more testers. cs3200f geniusvp2 hp3900 hp_rts88xx pixma stv680 What about the lexmark backend in experimental CVS? Can the code be imported into main CVS to get the Dell a)20 working? Bye, Henning
[sane-devel] Preparation for sane-backends release 1.0.18
Henning Meier-Geinitz henn...@meier-geinitz.de wrote: Hi, What's the status of the following external backends? Can they be included into sane-backends? Keep in mind that this gives you a much bigger audience and many more testers. geniusvp2 IIRC the geniusvp2 doesn't release ppdev problem is still there, although I'd have to check the last reports. This is something I patched already, but got a report months later telling the problem reappeared. Haven't got around to check the status on that since then. If someone can test report, please do. hp_rts88xx Has been running fine in libsane-extras for ages, no problems that I know of. It seems that hp_rts88xx supports the HP3500 scanners, and so does the hp3500 backend. Is it the case ? (the hp3500 scanner is listed in the comments at the top of the hp_rts88xx main source file) JB. -- Julien BLACHE http://www.jblache.org j...@jblache.org GPG KeyID 0xF5D65169
[sane-devel] Preparation for sane-backends release 1.0.18
Hi again, On 2006-04-18 17:54, Henning Meier-Geinitz wrote: I intend to start the countdown for the release of sane-backends 1.0.18 in a few weeks. So it's now the right time to include any big changes into sane-backends that are available. Especially big updates of existing backends and new backends should be included in the following weeks. One more question is about the status of the java api discussed some time ago on this list. Is it ok to remove the old japi code from sane-backends and add the new code to sane-frontends? Bye, henning
[sane-devel] Re: CanoScan LiDE20 jamming with scanimage
2006/4/18, Henning Meier-Geinitz henn...@meier-geinitz.de: Hi, On 2006-04-17 22:37, Fibonacci Prower wrote: Third update: I uninstalled all packages whose name contained the string sane, downloaded the sources from ftp://ftp.sane-project.org/pub/sane/for both frontends and backends, compiled them, installed them, ran xscanimage... And my scanner still jams. Maybe a problem with the USB part of the kernel used by your distribution? If you have a choice, try a different kernel. ... what? How do I change the kernel that came with FC5? (in newbie terms, please, for I have no experience with Linux) Bye, Henning -- sane-devel mailing list: sane-devel@lists.alioth.debian.org http://lists.alioth.debian.org/mailman/listinfo/sane-devel Unsubscribe: Send mail with subject unsubscribe your_password to sane-devel-requ...@lists.alioth.debian.org -- Ding dong! The bitch is dead! Which old bitch? The wicked bitch! Ding dong! The wicked bitch is dead! -- next part -- An HTML attachment was scrubbed... URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20060418/3f60454c/attachment.html From j...@jkdsoft.cjb.net Tue Apr 18 18:21:42 2006 From: j...@jkdsoft.cjb.net (JKD) Date: Tue Apr 18 18:50:14 2006 Subject: [sane-devel] Preparation for sane-backends release 1.0.18 In-Reply-To: 20060418155457.gh9...@meier-geinitz.de References: 20060418155457.gh9...@meier-geinitz.de Message-ID: 20060418182142.gb5...@jkdsoftware.dyndns.org El Tue, 18 de Apr de 2006, a las 05:54:57PM +0200, Henning Meier-Geinitz dijo: What's the status of the following external backends? Can they be included into sane-backends? Keep in mind that this gives you a much bigger audience and many more testers. hp3900 The fifth release (0.5) of this backend is still in alpha status. It seems to work well with normal/reflective scans in 8 and 16 bit depth and provides colour, gray and lineart modes (gray and lineart emulated in the backend yet) but slide/negative scans don't work properly and sometimes the scanner behaviour forces user to reset device. IMHO the backend is not ready to include in sane-backends. If you want to take a look: Changelog: http://svn.sourceforge.net/viewcvs.cgi/hp3900-series/ChangeLog?view=markuprev=48 Patch for sane-backends 1.0.17 stable: http://prdownloads.sourceforge.net/hp3900-series/hp3900-sane1017_src_0.5.tar.gz?download Other packages: https://sourceforge.net/project/showfiles.php?group_id=150599 Regards, Jonathan Bravo Lopez
[sane-devel] Hotplug and udev files created automatically now, please test!
Hi everybody, In SANE CVS the creation of the files libsane.usermap, libsane.db and libsane.rules is now done automatically from the backends' description files. libsane.usermap is used by Linux hotplug (tools/hotplug/) libsane.db is used by Linux hotplug-ng (tools/hotplug-ng/) libsane.rules is used by Linux udev (tools/udev) All three files are mainly used to set permissions on the USB device files (e.g. /proc/bus/usb/001/002). The files contain the USb vendor and product ids of all devices supported by SANE (and some more unsupported ones). They are created automatically from the backends' description files using the tool sane-desc. sane-desc is also used to generate our scanner lists on the web site. Therefore, now the lists are in sync and USB ids have to be added only in one place when a new scanner is reported. I can only test hotplug-ng at the moment. This works for me. Please test if hotplug and udev work with the new files. Bye, henning
[sane-devel] Canon CanoScan LiDE 25 ID's
Hi, On 2006-04-05 14:48, Tijmen wrote: The Canon CanoScan LiDE 25's ID's are 04a9:2220 Thanks. The IDs of this scanner are already included in the development version of SANE. Bye, Henning
[sane-devel] Preparation for sane-backends release 1.0.18
Le Mardi 18 Avril 2006 17:54, Henning Meier-Geinitz a ?crit?: Hi developers! I intend to start the countdown for the release of sane-backends 1.0.18 in a few weeks. So it's now the right time to include any big changes into sane-backends that are available. Especially big updates of existing backends and new backends should be included in the following weeks. What's the status of the following external backends? Can they be included into sane-backends? Keep in mind that this gives you a much bigger audience and many more testers. cs3200f geniusvp2 hp3900 hp_rts88xx pixma stv680 What about the lexmark backend in experimental CVS? Can the code be imported into main CVS to get the Dell a)20 working? Hello, I have yet to check in my latest developpements. Will do it tomorrow. Everything is finished: - arbitrary scan area - offset calibration - gain calibration - shading calibration is in place The only item left is to balance shading calibration. I have now all the data I need and I expect to have it work by the end of this week. However, it's up to the maintainer to give his opinion about inclusion. Regards, Stef
[sane-devel] Wanted: SnoopyPro and SniiffUSB Informations
Hello, In order to find the sane backend settings for my new Canon LiDE 500F scanner, I runn it on an Company Notebook with Microsoft Windows XP profesional installed (next to Linux). I tried to get logfiles with different settings from my scanner. But the results with SnoopyPro Version 0.22 and SniiffUSB was not helpfully at all. The SniiffUSB was not working, this means it shows me all of the USB devices, but dit not produce any logfile about the USB trafic. SnoopyPro creates only logfiles, when the scanner device was either reseted from this program, or disconnected and reconnected from the USB bus. It logs then alway 546 packets and stop logging. The problem is, to find a usable explanation for this program. The only on I found is verry short and don't give any hints about trouble shooting. Can any one help with an usefull description? Gruss Martin -- Microsoft makes the easy stuff easy, and the rest impossible. Unix makes everything possible, but nothing too easy.