[sane-devel] Disable tiff

2006-08-13 Thread JKD
Hello,

Is there any possibility to compile sane backends without tiff
libraries? I've tried to disable that feature using --disable-tiff
option in configure script but it doesn't work. 

Regards, JKD



[sane-devel] Scanmaker 4 i/o errors

2006-08-13 Thread Steven Hillis
So, I know this isn't on the supported page, but I've seen in quite a few
places that people report success in using them with sane.

Also, appologies if this is already answered in the mailing list archive,
but it doesn't recognize phrase searches, and after about 30 pages of
Scanmaker results that have nothing to do with the problem, or even this
model of scanner, it seemed a rather large waste of time to continue
looking.

I have a Microtek Scanmake 4 rev. 01, it is picked up by sane, and it can go
so far as to preview scan, but that is it.

It goes up to:

scsi_send_gamma: pos=0x808a360, size=8192, word=1, color=3
[microtek2] scsi_set_window: ms=0x8079220, wnd=1
[microtek2] scsi_read_image_info: ms=0x8079220
[microtek2] scsi_read_image_info: ppl=611, bpl=1836, lines=1007,
remain=1848852
[microtek2] prepare_buffers: ms=0x0x8079220
[microtek2] calculate_sane_params: ms=0x8079220
[microtek2] scsi_wait_for_image: ms=0x8079220
[microtek2] scsi_read_image_status: ms=0x8079220
[microtek2] scsi_read_image_status: use old image status
[microtek2] scsi_sense_handler: fd=3, sense=0xb768d060 arg=(nil)
[microtek2] dump_area: SenseBuffer
[microtek2]  0: f9000216 6000 `...
[microtek2] 16: 4c616d702066 61696c7572  ..Lamp f ailur
[microtek2] scsi_sense_handler: SENSE KEY (0x09), ASC (0x60), ASCQ (0x00)
[microtek2] scsi_sense_handler: info: 'Lamp failure'
[microtek2] scsi_sense_handler: Lamp failure
[microtek2] scsi_read_image_status: 'Error during device I/O'
[microtek2] scsi_wait_for_image: 'Error during device I/O'

then stops.

Ok, so, lamp failure, that sounds pretty self explanatory... but the preview
still works, and the last time I used it in Windows (admittedly about a year
ago) everything ran fine.

Now, I'm not so much looking for someone else to solve my problem as much as
informing me of a couple things.

First, should the scanner still be capable of a preview scan if the lamp is
failing? I've opened the thing up and everything *looks* to be working
correctly (all the lights are still working).

Second, will it damage the scanner in any way if I remove the failure check
and force it to scan anyway, assuming the lamp actually is going out?

Any help with this would be appreciated.
-- next part --
An HTML attachment was scrubbed...
URL: 
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20060812/c65de1cb/attachment.htm
From adeur...@gmx.net  Sun Aug 13 12:34:26 2006
From: adeur...@gmx.net (abel deuring)
Date: Sun Aug 13 12:29:11 2006
Subject: [sane-devel] Scanmaker 4 i/o errors
In-Reply-To: 340594530608121920n5433cee4i1734e9c003325...@mail.gmail.com
References: 340594530608121920n5433cee4i1734e9c003325...@mail.gmail.com
Message-ID: 44df1c52.2040...@gmx.net

Steven Hillis wrote:

 [microtek2] scsi_sense_handler: fd=3, sense=0xb768d060 arg=(nil)
 [microtek2] dump_area: SenseBuffer
 [microtek2]  0: f9000216 6000 `...
 [microtek2] 16: 4c616d702066 61696c7572  ..Lamp f ailur
 [microtek2] scsi_sense_handler: SENSE KEY (0x09), ASC (0x60), ASCQ (0x00)
 [microtek2] scsi_sense_handler: info: 'Lamp failure'
 [microtek2] scsi_sense_handler: Lamp failure
 [microtek2] scsi_read_image_status: 'Error during device I/O'
 [microtek2] scsi_wait_for_image: 'Error during device I/O'
 
 then stops.
 
 Ok, so, lamp failure, that sounds pretty self explanatory... but the
 preview still works, and the last time I used it in Windows (admittedly
 about a year ago) everything ran fine.
 
 Now, I'm not so much looking for someone else to solve my problem as
 much as informing me of a couple things.
 
 First, should the scanner still be capable of a preview scan if the lamp
 is failing? I've opened the thing up and everything *looks* to be
 working correctly (all the lights are still working).
 
 Second, will it damage the scanner in any way if I remove the failure
 check and force it to scan anyway, assuming the lamp actually is going out?

well, I'm not an expert for Microtek scanners or the microtec2
backend, but around line 3950 in microtec2.c the values of
ms-fastscan and ms-quality are set depending on the value of the
Sane option OPT_PREVIEW, and around line 4560 ms-fastscan and
ms-quality are used to set some bits in the data of the SET WINDOW
command. So it seems that these two parameters, or one of them, tell
the scanner to be more picky regarding the light quality. Before
starting a scan, most scanners calibrate the lamp and the CCD
sensor, typically by moving the scan head to positions where they
see a white and a black area, so that they can measure the CCD
output for these colours.

If this fails, because there are maybe too large deviations in the
signal returned by the CCD over the scan width, or if the CCD signal
for white is too low, the scanner's firmware may complain.

So, if scan quality is not that important for you, you could try to
constantly set ms-fastscan and/or 

[sane-devel] Epson R640 issues with MS Publisher

2006-08-13 Thread Bridget Ryder
Hiya! I was reading your web message regarding the patch you had found for a 
problem with an Epson printer. I wonder if you could possibly help me. I 
have an Epson R640 and do alot of basic design work in Microsoft Publisher. 
Every time I go to print out my work on glossy paper, the computer reverts 
to it's default settings (standard paper). I don't think it's the computer 
because i've had the printer plugged into other people's computer and the 
same problem arises. I've always used Epson printers but this is the first 
time I've encountered anything like this. It is extremely frustrating, and 
I'd appreciate ANY advice you can offer! thankyou (:

Artbird

_
Be the first to hear what's new at MSN - sign up to our free newsletters! 
http://www.msn.co.uk/newsletters



[sane-devel] (fwd)

2006-08-13 Thread Bakos Gy|rgy
Package:hplip
Version:1.6.7-1

Scan Issue: hplip or sane is the problem...
Exactly the same error everywhere with HP laserjet 3300

http://www.ubuntuforums.org/archive/index.php/t-190239.html
http://ubuntuforums.org/showthread.php?t=148017highlight=sane+document+feeder

It is complaining (sane_start) about the feeder, but this
has not any feeder!!

dmesg:
ppdev0: registered pardevice
ppdev0: unregistered pardevice
ppdev0: registered pardevice
ppdev0: unregistered pardevice
drivers/usb/class/usblp.c: usblp0: nonzero read/write bulk
status received: -2
drivers/usb/class/usblp.c: usblp0: error -2 reading from printer
drivers/usb/class/usblp.c: usblp0: nonzero read/write bulk
status received: -2



/var/log
Aug 12 15:40:01 localhost kernel: ppdev0: registered pardevice
Aug 12 15:40:01 localhost kernel: ppdev0: unregistered pardevice
Aug 12 15:40:03 localhost kernel: ppdev0: registered pardevice
Aug 12 15:40:03 localhost hpiod: ParDevice::nibble_read
failed: Input/output error
Aug 12 15:40:03 localhost kernel: ppdev0: unregistered pardevice
Aug 12 15:40:04 localhost kernel: drivers/usb/class/usblp.c:
usblp0: nonzero read/write bulk status received: -2
Aug 12 15:40:05 localhost kernel: drivers/usb/class/usblp.c:
usblp0: error -2 reading from printer
Aug 12 15:40:05 localhost kernel: drivers/usb/class/usblp.c:
usblp0: nonzero read/write bulk status received: -2


I have a latest ETCH release (CUPS/HPLIP works fine) after
all I decide to use the unsrable from hplip, but with same
result.

scanimage -L

device
`hpaio:/usb/HP_LaserJet_3300_3310_3320?device=/dev/usb/lp0'
is a hp HP_LaserJet_3300_3310_3320 multi-function peripheral



T?ltsd le Baby Gabi ?s Kefir, Dobr?dy ?kos valamint a Desperado leg?jabb dalait 
a T-Online Zene?ruh?zb?l!
http://zenearuhaz.t-online.hu




[sane-devel] (fwd)

2006-08-13 Thread abel deuring
Bakos Gy|rgy wrote:
 Package:hplip
 Version:1.6.7-1
 
 Scan Issue: hplip or sane is the problem...
 Exactly the same error everywhere with HP laserjet 3300
 
 http://www.ubuntuforums.org/archive/index.php/t-190239.html
 http://ubuntuforums.org/showthread.php?t=148017highlight=sane+document+feeder
 
 It is complaining (sane_start) about the feeder, but this
 has not any feeder!!

The hplip backend is not a part of sane-backends; it is maintained
independently as a sourceforge project:
http://hplip.sourceforge.net/ . Since you obviously get an error
message from that backend, you should tell the hplip backend
maintainers about this bug.

Abel



[sane-devel] Epson R640 issues with MS Publisher

2006-08-13 Thread m. allan noah
uhm- this is the mailing list for a group that develops scanner drivers 
for unix based machines. not printing, not MS windows. perhaps you should 
ask epson?

allan

On Fri, 11 Aug 2006, Bridget Ryder wrote:

 Hiya! I was reading your web message regarding the patch you had found for a 
 problem with an Epson printer. I wonder if you could possibly help me. I have 
 an Epson R640 and do alot of basic design work in Microsoft Publisher. Every 
 time I go to print out my work on glossy paper, the computer reverts to it's 
 default settings (standard paper). I don't think it's the computer because 
 i've had the printer plugged into other people's computer and the same 
 problem arises. I've always used Epson printers but this is the first time 
 I've encountered anything like this. It is extremely frustrating, and I'd 
 appreciate ANY advice you can offer! thankyou (:

 Artbird

 _
 Be the first to hear what's new at MSN - sign up to our free newsletters! 
 http://www.msn.co.uk/newsletters




-- 
so don't tell us it can't be done, putting down what you don't know.
money isn't our god, integrity will free our souls - Max Cavalera


[sane-devel] Backend for MS fingerprint scanners

2006-08-13 Thread Gerard Klaver
On Wed, 2006-08-09 at 19:37 -0300, Gustavo Torres wrote:
 Hello,
 I'm looking for a Microsoft fingerprint scanner (aka DigitalPersona
 UareU 4000B) backend, but I couldn't find it.
 If someone is aware of any effort to implement it, please let me know.
 I'm considering developing one.
 Regards,
 
 -- 
For information, not for your type, but for the Authentec AES2501 i am
developing a authentec fingerprint scanner backend.

See: http://gkall.hobby.nl/authentec.html

No working backend yet, still some init problems.
-- 

m.vr.gr.
Gerard Klaver