Netware Cluster config question

2003-12-15 Thread David Longo
I have TSM server 4.2.3.4 and am setting up a Netware 6.0 Cluster with TSM client 5.1.6.0. The Netware Admin is doing most of this. He says that he needs to unload dsmc in a NCF file. However it prompts you if you really want to do this etc. The NCF script doesn't allow passing parameters to

Re: Netware Cluster config question

2003-12-15 Thread Wolfgang Bayrhof
Hi David, you shouldn't execute unload dsmc by a ncf-batch, because there's a good chance to crash the NetWare server with this command. That's probably the reason for the prompt. Additionally all DSMC stanzas of all cluster-resources on the corresponding node would be unloaded by the ncf-file

Re: Netware Cluster config question

2003-12-15 Thread Jim Kirkman
This is exactly the procedure we use. Works beautifully. Wolfgang Bayrhof wrote: Hi David, you shouldn't execute unload dsmc by a ncf-batch, because there's a good chance to crash the NetWare server with this command. That's probably the reason for the prompt. Additionally all DSMC