Re: [casper] ROACH2 4-element correlator compilation error

2018-01-17 Thread James Smith
Hello Bela, I second Andrew's suggestion, but note also that "Error due to multiple causes" can often mean that somewhere in the design there's a name that Matlab doesn't like. Avoid using any capital letters or spaces in block names, and avoid using names that are too long - if the full

Re: [casper] ROACH2 4-element correlator compilation error

2018-01-17 Thread Andrew Martens
Hi Bela Please open you design in Matlab/Simulink and then Press 'Ctrl-D' (hold the Ctrl key down and hit the D key at the same time). This will do an 'Update' on your design and will give more useful error messages. Regards Andrew On Thu, Jan 18, 2018 at 7:28 AM, Bela Dixit

Re: [casper] adc5g four inputs

2018-01-17 Thread Dan Werthimer
hi michael, i don't know anyone who has converted the dual input ADC5G to a quad input board; as you pointed out, you'd to add two sma connectors, two baluns, and associated input circuitry. if you need several of these, it might be best to make a revised PCB. there are a few companies that make

[casper] adc5g four inputs

2018-01-17 Thread Michael D'Cruze
Dear all, Does anyone know if the "adc5g" board in its broadly existing form can be operated using all four inputs independently? I have in mind that a minor rework of the HDL code and yellow block, and additional SMA connectors could be installed, without requiring a completely new board to