Package: acpi
Version: 1.1-2
Severity: minor

Hi,

It seems that acpi is getting a bit confused as to the difference between mAh 
and mWh:

maul...@cheshire:~$ cat /proc/acpi/battery/BAT0/info 
present:                 yes
design capacity:         74880 mWh
last full capacity:      71270 mWh
battery technology:      rechargeable
design voltage:          14400 mV
design capacity warning: 3563 mWh
design capacity low:     200 mWh
capacity granularity 1:  1 mWh
capacity granularity 2:  1 mWh
model number:            42T4568
serial number:            4759
battery type:            LION
OEM info:                SONY
maul...@cheshire:~$ acpi
     Battery 0: Charging, 12%, 25:15:57 until charged, design capacity 74880 mAh


Cheers,
Neil