Package: acpi Version: 1.1-2 Severity: minor Hi,
It seems that acpi is getting a bit confused as to the difference between mAh and mWh: maul...@cheshire:~$ cat /proc/acpi/battery/BAT0/info present: yes design capacity: 74880 mWh last full capacity: 71270 mWh battery technology: rechargeable design voltage: 14400 mV design capacity warning: 3563 mWh design capacity low: 200 mWh capacity granularity 1: 1 mWh capacity granularity 2: 1 mWh model number: 42T4568 serial number: 4759 battery type: LION OEM info: SONY maul...@cheshire:~$ acpi Battery 0: Charging, 12%, 25:15:57 until charged, design capacity 74880 mAh Cheers, Neil -- System Information: Debian Release: 5.0.2 APT prefers stable APT policy: (500, 'stable') Architecture: i386 (i686) Kernel: Linux 2.6.26-2-686 (SMP w/2 CPU cores) Locale: LANG=en_GB.UTF-8, LC_CTYPE=en_GB.UTF-8 (charmap=UTF-8) Shell: /bin/sh linked to /bin/bash Versions of packages acpi depends on: ii libc6 2.7-18 GNU C Library: Shared libraries acpi recommends no packages. acpi suggests no packages. -- debconf-show failed -- return (test == true)? ( (test == false)? false : true) : ((test == false) ? false : true);
signature.asc
Description: Digital signature