2011/8/7 Sebastian Schmidt y...@yath.de:
Upstream commit r4987 (Use libusb-1.0 instead of libusb-0.1) breaks
communication with my reader (REINER SCT cyberJack RFID basis, USB
0c4b:9102).
When sending an APDU to the reader, e.g. via scriptor, libccid hangs
while waiting for data from the
close 637022
thanks
On Mon, Aug 08, 2011 at 11:16:23AM +0200, Ludovic Rousseau wrote:
Can you reproduce the problem with a recent libusb?
Try with the version available at
http://ludovicrousseau.blogspot.com/2011/05/new-version-of-libusb-part-2.html
Yep, that one indeed fixes it. I'll go bug
Package: libccid
Version: 1.4.4-1
Severity: normal
Tags: upstream patch
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Upstream commit r4987 (Use libusb-1.0 instead of libusb-0.1) breaks
communication with my reader (REINER SCT cyberJack RFID basis, USB
0c4b:9102).
When sending an APDU to the
3 matches