Hi John,
we assume a switch restarted when we get the following syslog-message:
dtl_end.c(241) 332733 %% DTL avl mac delete ALL error!
The standard SNMP-MIB shows Uptime as well and can be used by any
SNMP-Tool/Console.
Best Regards
i.A. André Keller
Informationssysteme Lokaler Betrieb und
Hi,
we use rancid (uses expect) for that as well. We only have C-Series-Switches
but i think it should work for B-Series as well.
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler Betrieb und Support
Volkswagen Original Teile Logistik GmbH und Co. KG
Vertriebszentrum
Hi there,
we use rancid to do exactly that (it´s not vendor specific!). Rancid uses
expect and puts the output into CVS/SVN. Mails
you diffs, too.
I just had to edit a couple of scripts to work with enterasys. If anyone is
interested just drop me a line.
regards,
André
Mit freundlichen Grüßen
Hi Tim,
we do monitor all our network equipment with Cacti and enterasys works okay
with it.
The standard MIBs all work, the CPU/Memory/Process implementation sometimes
come up lacking (C3 CPU SNMP-values
go well above 100% in some cases).
Also, if u like MRTG you´ll love Cacti :). It´s like
Hi there,
we found the system that was responsible for the root-Logins, it was our
HP SIM-Server
(http://h18013.www1.hp.com/products/servers/management/hpsim/index.html?jumpid=go/hpsim).
It might have been a bit overachieving in getting root access to check for
whatever.
The spoofed IP will
Hi there,
does anyone know if this message should be cause for concern:
CLI[6]User: root failed login from 127.128.0.4(ssh)
We had this coming up on one of our N7 for a couple of times
yesterday. The IP 127.128.0.4 is related to OSPF afaik which we
don´t use at all anywhere.
Also, we don´t have
The N7 is not in any way connected to the internet, stictly LAN Distribution
Switch.
We got no loopback addresses configured, so i´ll be keeping an eye out on any
other attempts.
-Ursprüngliche Nachricht-
Von: Stephen Loeckle [mailto:sloec...@lucidnetworks.net]
Gesendet:
Hi James,
quickest way that works for me:
sh conf vlan.
A sh port vlan should help as well.
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler Betrieb und Support
Volkswagen Original Teile Logistik GmbH und Co. KG
Vertriebszentrum Nord
Am Stammgleis 6
22844 Norderstedt
Hi Michael,
we had tremendous trouble getting the Controller communicate properly with a
Funk Steel Belted Radius (now Juniper) V5.4.1.
which Enterasys could not solve (or Juniper for that matter). We ended up
upgrading to Windows 2008 Radius-Server
which works so far as expected.
To get to
Hi Isabel,
i have templates for C-Series (at least C2+3) and N-Series for monitoring
general CPU usage and individual process CPU usage.
As Aaron already stated: you can use the default Cacti-Templates for
port-statistics (errors, traffic).
Enterasys adheres to the standard-MIB.
If you want
Hi Cully,
i derived the scripts for the HiPath from our Cacti scripts that worked for
the RoamAbout series as well. We have about 500 APs distributed over 8
Roamabout-Switches
and are in the process of switching over to 2 HiPath-C5110. The
HiPath-Controller
shows no sign of a memory leak (so
Hi Dean,
we use Cacti for that, you´ll find templates under
http://docs.cacti.net/usertemplate:data:enterasys:hipathwc
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler Betrieb und Support
Volkswagen Original Teile Logistik GmbH und Co. KG
Vertriebszentrum Nord
Am
Hi Stefan,
if you like Mactrack (and Cacti in general) you might like to take a look at
Netdisco
which works really good with Enterasys devices. It comes with a VM as well,
so more hassling through FreeBSD installations.
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler
Hi Reinhard,
i agree! I´d like to see powersupply, temperature and memory-usage MIBs.
The rest was introduced in 5.01 C2-Firmware (I think) and can be monitored
quite well. One feature you didn´t mention (but Enterasys put into the MIBs) is
the ability to monitor all the threads/processes and how
Hi all,
Just to add my 2c, you might need to check from which firmware you upgrade to.
Upgrading from 5.0.x to 5.2 won´t work and i encountered similar issues.
So, first upgrade to 5.1 and then to 5.2.
Hope this helps!
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler
-
From: Keller, Andre ( OTLG ) [mailto:andre.kel...@volkswagen-otlg.de]
Sent: Tuesday, August 03, 2010 11:43 PM
To: Enterasys Customer Mailing List
Subject: AW: [enterasys] HiPath monitoring
Hi Matt,
we are using Cacti as our main monitoring- and trend-tool. I´m in the
process of writing
Hi there,
i can recommend Netdisco for a Port-Inventory. It includes duplex-mismatch
reports besides a lot of useful extra
stuff. Nowadays available as a pretty easy to set up VM: http://netdisco.org/
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler Betrieb und Support
Hi Stephen,
it´s based on FeeBSD.
Mit freundlichen Grüßen
i.A. André Keller
Informationssysteme Lokaler Betrieb und Support
Volkswagen Original Teile Logistik GmbH und Co. KG
Vertriebszentrum Nord
Am Stammgleis 6
22844 Norderstedt
Tel.: +49 (40) 52200-3211
Fax: +49 40 52200-3209
Hi Connie,
did you update the firmware in several steps? I think you´ll have to update
from 3.x - 4.x - 5.0.x and finally 5.2.x if i remember correctly.
There was a POE Module Update in there somewhere which might be the reason for
your port loss. Try restoring the switch to factory defaults
Hi there,
this is what we use for the C2/3 (should work with B-Series as well):
1min_cpu .1.3.6.1.4.1.5624.1.2.49.1.1.1.1.3.1.1
5min_cpu .1.3.6.1.4.1.5624.1.2.49.1.1.1.1.4.1.1
5sec_cpu .1.3.6.1.4.1.5624.1.2.49.1.1.1.1.2.1.1
ram .1.3.6.1.4.1.5624.1.2.49.1.3.1.1.5.3.2.0
Caution with monitoring
Hi there,
we use the 05.02.01.0006-firmware for all our C2 devices and expierencing
quite some problems for some time now.
I already opened a GTAC but i´d like to know, if anyone else is having problems
with that particular firmware!
The only error-message i can get after the switch rebooted is
21 matches
Mail list logo