Re: [go-nuts] compiling go-1.22.2 and go-1.21.9 fail due to timeout during test of net/http package

2024-04-21 Thread Ron Hermsen
Thanks for informing it is actually installed fine at the time it is failing the test. My TCL VM is running as a nested VM, and resources are limited (one CPU, 8GB Ram is assigned for this VM). Assuming only fixes are back-ported to 1.21.x it is likely a fix that affects both 1.22.2 and 1.21.9 in

Re: [go-nuts] compiling go-1.22.2 and go-1.21.9 fail due to timeout during test of net/http package

2024-04-20 Thread Ian Lance Taylor
On Sat, Apr 20, 2024 at 7:34 PM Ron Hermsen wrote: > > compiling go-1.22.2 and go-1.21.9 fail due to timeout during test of net/http > package > > I tried a number of earlier releases but looks only the latest two fail. > (each build takes about 40min, so didn't try more options) > > > ok

[go-nuts] compiling go-1.22.2 and go-1.21.9 fail due to timeout during test of net/http package

2024-04-20 Thread Ron Hermsen
compiling go-1.22.2 and go-1.21.9 fail due to timeout during test of net/http package I tried a number of earlier releases but looks only the latest two fail. (each build takes about 40min, so didn't try more options) ok net 8.598s panic: test timed out after 9m0s running tests: FAIL