https://bugs.kde.org/show_bug.cgi?id=437066
Bug ID: 437066 Summary: Widget loses Uptime sensor when Plasma is restarted Product: plasmashell Version: 5.21.90 Platform: Archlinux Packages OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: System Monitor Assignee: plasma-b...@kde.org Reporter: bugsefor...@gmx.com CC: ahiems...@heimr.nl, notm...@gmail.com Target Milestone: 1.0 SUMMARY Reproducible on both Arch Linux (Plasma 5.22 beta) and neon unstable. STEPS TO REPRODUCE 1. add System Monitor Sensor to desktop 2. open widget settings 3. select "Text only" display style and apply it 4. click on "Sensors details" section 5. click on "Text-only sensors" row 6. search for "uptime" sensor and add it 7. close widget settings by clicking on "OK" button 8. restart Plasma running "plasmashell --replace" with Krunner OBSERVED RESULT System Monitor Sensor widget is empty, Uptime sensor disappeared EXPECTED RESULT Uptime sensor should be preserved after we restart Plasma SOFTWARE/OS VERSIONS Operating System: Arch Linux KDE Plasma Version: 5.21.90 KDE Frameworks Version: 5.82.0 Qt Version: 5.15.2 Graphics Platform: Wayland -- You are receiving this mail because: You are watching all bug changes.