how to connect to MSAccessfrom LAbView

2004-04-24 Thread NELCO
i want to log the data from the labview7.0 to MSAccess database and generate reports.what tools i require for this connectivity and report generation. Pl.suggest me.Thank you.

Re: In Port8.vi Out Port8.vi LV7 EXECUTABLE portability problem

2004-04-24 Thread bilik
It works! I'm not using embeded LV installer for years, now I see I miss something... Thank you very much. Petr Bilik

Re: Why Do LV7 VIs Stop Executing When I Click on the Window Title Bar?

2004-04-24 Thread Andrey Dmitriev
Hi, Tim This problem normally occured when your VI constantly switch back and forth to the user interface thread. Probably you have some VIs, functions or operations, which running in the UI thread: - Property Nodes - Menu Control VIs - VI Server - Thread Unsafe CINs or DLLs. Be sure, that all of

Re: Driver Templates

2004-04-24 Thread Tom Hawkins
For some reason the ends of two paragraphs were chopped off the message I sent yesterday (on the old list): you didn't miss much, but if anyone was curious the missing snippets were: 'Hideous' you are welcome to interpret as a matter of personal artistic taste ;-) and but mostly the problem

Re: Can i make the communication of Raynger MX4/MX6 ?

2004-04-24 Thread [EMAIL PROTECTED]
Hallo Dennis: Thank you for your help. But i don't know how can i add the Serial End Mode for Writes to the VISA Instr property node and use TermChar as a value. Can you send me a example. thank very much. Long.

Re: Windows system variable

2004-04-24 Thread konkari
Thank you. I have wrote the attached vi and it seems that is working for Windows 2000. Regards Pere

Re: Probleme sur ecriture disque,

2004-04-24 Thread Cyn
Je n'ai rien trouv=E9 dans notre base interne concernant des probl=E8mes similaires au votre. La seule chose que je puisse vous proposer actuellement c'est de remettre un commentaire si le probl=E8me se reproduisait et de me renvoyer un exemple permettant de reproduire votre probl=E8me afin que

parallel input using control register

2004-04-24 Thread nightlight
Hi, all. i have beening trying to use the control register and the status register as parallel port input. i have read the article named Using the Parallel Port in LabVIEW at the address http://zone.ni.com/devzone/conceptd.nsf/webmain/72C6FC6CE4AD4D1386256B1800794596?opendocument; i did exactly

RE: Info-LabVIEW Digest - 04/21/04

2004-04-24 Thread Rubin, Gary
Hello, I receive my info-labview mailings as a daily digest. Rather than being text message as before, those coming from the new address contain a text listing of subjects, then a bunch of attachments. The first day, there was an attachment for each entry in the list of messages. Today, I

3D multiplot mesh

2004-04-24 Thread Orko
I have 5 different signals with x,y and z values. Want to show all signals in different colors in 3D multiplot mesh.#305; use Labview 7.0, Thanks...

Acquire N Scans doesn't work

2004-04-24 Thread Giulia
Acquire N Scans VI (it is an example VI) does't work to collect noise ( no input connected)

editing analog waveforms (amplititude)using mouse

2004-04-24 Thread coolraj
I want to edit arbitary analog waveforms graphically using a mouse,for example to edit the amplitude of a waveform irregularly just by drawing with a mouse.I tried the analog waveform editor but it doesn't seem to have such facility.Is there anyother tool which I can use ?? Thanks in Advance

j'ai un pb avec CIN

2004-04-24 Thread jawkar
je compile mon code.c cr=E9er par labview sous VS resultat : fatal error C1083: Cannot open include file: 'extcode.h': No such file or directory

I'm a beginner struggling with a simple task in programming, can someone help?

2004-04-24 Thread James Bennett
Very simple, if I can explain it right. OK, Lets say I have a VI with 3 string controls, 3 numeric controls and a Start and Stop button. 8 items total. Now, when I press the start button I want another front panel (separate VI) to open up which will display the 3 strings in string indicators

Format of new digest messages

2004-04-24 Thread Mark . E . Watson
Hi, Well, I hate to complain but obviously I don't hate it enough to not do so, so here goes. I receive Info-LabVIEW in the digest form and the new list has changed the format. Old list: I would receive one message with each message appended to the digest in

Inherited reentrancy?

2004-04-24 Thread CoastalMaineBird
I understand some things about reentrancy: Say my SubVI S has an uninitialized shift register that is supposed to remember some value V from one call to the next. If S is normal (not re-entrant), and S is called from two or more places, then there is only one V - each caller would interact with

Re: Acquire N Scans doesn't work

2004-04-24 Thread shoneill
I'm not quite sure what you mean. If you mean that the A/D card delivers no values when there's nothing connected, then I'd contact whoever sells the card. If you mean that the LabVIEW function doesn't work without wiring channels to it, then I agree it doesn't work. You need to wire a channel

Re: probleme de fonctionnement avec Multiple Pulse-Train Generation with Phase Shifts (NI-TIO)

2004-04-24 Thread Kerouac
Bonjour, Vous voulez g=E9n=E9rer un train de pulses avec des rapports cycliques diff=E9rents =E0 chaque pulse. Vous devez pour cela reprogrammer les sp=E9cifications des pulses g=E9n=E9r=E9s par le compteur =E0 la vol=E9e, c'est-=E0-dire en simultan= =E9 pendant la g=E9n=E9ration. Il existe pour

Re: problem with NI- TIO Examples

2004-04-24 Thread michenaud
merci d'avoir repondue j aimerais savoir quelle est la difference entre l entr=E9e gate specification du VI gate et le VI counter start trigger. Sachant que je veux me synchronis=E9 via un g=E9n=E9 externe. est il possible de se synchronis=E9 sans generateur externe? cordialement, didier.

PC Crash with Labview 7 and windows 2000

2004-04-24 Thread sergiost
Problem: the PC does reboot without any prompt when a LV 7 vi is running; the reboot seems to occur randomly (no time dependent); sometimes instead of rebooting, the PC switches to the blue screen with the following message: Stop: 0x001E (0xC002, 0x80419292, 0x, 0x)

Re: editing analog waveforms (amplititude)using mouse

2004-04-24 Thread coolraj
Excellent work !! thanks a lot mate !! That was very useful. Thanks once again, Rajan

Re: probleme de fonctionnement avec Multiple Pulse-Train Generation with Phase Shifts (NI-TIO)

2004-04-24 Thread Kerouac
NI-DAQ est le driver pour les cartes d'acquisition NI. Il fournit le jeu de fonctions pour programmer les cartes NI qui peuvent embarquer diff=E9rents types de chip. NI-TIO est le chip de gestion des signaux de timing des cartes 660x. DAQ-STC est un autre chip de gestion des signaux de timing pour

How 2 change the IP address of the PC with Lavbview

2004-04-24 Thread masterryo
Hi every body, I am developping a Labview 6.1 program on windows 2000. This programm writes bytes on a distant machine with a certain ip configuration (address, mask). The Pc running the programm does not alwys have the same config. My question: Is there a way to changfe the ip address of the

Re: Inherited reentrancy?

2004-04-24 Thread Ed Dickens
This could get confusing quick, but I think I understand how it all works. The reentrant property does not affect any callers or callees'. It strictly on a VI by VI basis. In your last example, there would be 4 values of 'V', since both C and S are reentrant, 'M' would call two instances of 'C',

Re: How do I get a print dialog window ?

2004-04-24 Thread Joe Guo
Someone might have better answers, however, here is my 2c. To Q1, I use an application called fine print, when it set as default, it will popup everytime when there is a print opeartion and you can choose what printer to print to and set other settings as well. You can preview the print content

Re: RS 485 and labview (for use with Brooks 5850s mass flow controllers)

2004-04-24 Thread stu22
Hi, thanks for your response, sorry i'm so late in replying(been on holiday). if u could send the brokes vi's to this address [EMAIL PROTECTED] it would be much appreciated.And i would be interested in purchasing the source code. Thanks Stuart

spectre fréquence sous labview

2004-04-24 Thread beun
bonjour, je dois d=E9finir le spectre d'un signal, pour cela j'ai tent=E9 d'utiliser FFT Power Spectrum.vi et FFT spectrum (Mag-phase).vi. Dans les 2 cas le r=E9sultat graphique que j'obtiens en sortie de ces vi n'est pas correct, la fr=E9quence est en y et ne cesse d'augmenter, au lieu d'=EAtre

need vi for bar code reader Symbol CS1504 USB

2004-04-24 Thread Test Engineering Leader
Need a vi to down load collected date/time and bar code from Symbol CS1504 through USB port. Also need command to 'flush' the reader from stored data.

Re: Inherited reentrancy?

2004-04-24 Thread CoastalMaineBird
OK, thanks. The confusing thing for me is that S would have FOUR callers (and thus FOUR values of V), even though there are only TWO instances of it in the code.

Re: Inherited reentrancy?

2004-04-24 Thread CoastalMaineBird
OK - that occurred to me that there could be 4 values of V, but I wasn't sure. (It's good in my case). I had always thought about it in terms of callers - there is one V for each caller instance. But if the caller is reentrant itself, then S has FOUR callers, EVEN THOUGH there are only two

Re: How do I get a print dialog window ?

2004-04-24 Thread Act
Are you talking about Labview Tools here or something else ?

Re: Modbus not working with LabView7 Runtime

2004-04-24 Thread eps2
Here is a little twist. I usually do not show my subVi's when running. I did a little more troubleshooting and changed this subVi to show when called and it works fine. Any Ideas?

Re: Why am I getting very high values for the very low frequency region of a random signal?

2004-04-24 Thread Act
What you have said is really informative. Thanks a lot! You suggested not using a window, but if I try without one, the spectrum is crowded without any clear pattern showing up. I think not removing the dc, was the problem why that high value for 0.0033 HZ showed up. You talk about bins here, how

My IIC Vi's are not working anymore with LabView 7, does...

2004-04-24 Thread Carmo
My IIC Vi's are not working anymore with LabView 7, does somebody has a solution (hardware+software) for use IIC in this LabView version? Usually i worked with LabView 6 and i had no problems with IIC communications, but due to some reasons i made the upgrade to vertion 7 and I'm facing some

Re: spectre fréquence sous labview

2004-04-24 Thread LocalDSP
When you say you fill your time data array dynamically, do you mean the length of the array change? The reason I am asking is that the behavior you describe is weird. The only thing that can make your Y-values grow is if the energy in each bin grows. This can happen if: 1 - You bin size gets

Re: functional circuit test

2004-04-24 Thread Dennis Knutson
The first thing to study is the board that you're testing. You should have a good basic understanding of its operation. Whfen you functionally test something, you are attempting to recreate the normal working environment of the board and verify that it meets it's design specifications. You will

Re: datasocket control - cwds not registerable as an activex component

2004-04-24 Thread jaggedmedia
thanks

Re: daq question

2004-04-24 Thread Process Systems
First off, you must ensure that the daq channel you wish to use is a high impedance input. This is not normally a problem, as any daq board I have used is in the hi-K's to Meg ohms input. The Omron will normally supply a constant current drive to the RTD, and then measure the voltage across it,

Re: How do I get a print dialog window ?

2004-04-24 Thread Joe Guo
both tools are external applications. -Joe

Re: Why am I getting very high values for the very low frequency region of a random signal?

2004-04-24 Thread LocalDSP
I would recommend you to read for example the LabVIEW Analysis Concepts document that explains all the different concepts, bin, averaging etc... You can access the document from your Desktop: StartProgramsNat. Inst.LabVIEW **Search the LabVIEW Bookshelf Select the Measurement Manual or the

caps-lock

2004-04-24 Thread David Ferster
A little off-topic, but I use the tab key to change tools all the time. Since my different keyboards are slightly different, as I go back and forth between computers and get confused. So I miss the tab key a lot and hit the caps-lock key. I drived me nuts. Does anyone ever use the caps-lock

Looking for third party driver for Bentley Nevada 208P data acquisition unit.

2004-04-24 Thread terry
We have a Bentley Nevada 208P data acquisition unit used with their Adre system (software/hardware). We would find it benifitial to utilize it on another application other than monitoring proximitors, and do some calculations on the voltage signals received outside Bentley's Adre system software.

How do I save a mutlitcolumn data to a text file?

2004-04-24 Thread Act
I am trying to save a multicolumn data to a text file without using Report Generation VIs. Here is the detail scenario... I have data in the following format. Time Voltage 1 2 2 3 3 6 ... and Power 1 and Peaks x-axisy-axis Peak1 1 4 Peak2 5

Re: Limit to the sampling rate for an HP4192 Impedance Analyzer?

2004-04-24 Thread Brian Beal
I have never used the 4192, but am familiar with the 4194a. I can easily get 20 cap readings/second in a loop. Cap readings typically happen quickly. What parameters do you have set up in the 4192 for the cap readings? Are you doing a sweep of many frequencies? Using averaging, etc.? What are

Re: editing analog waveforms (amplititude)using mouse

2004-04-24 Thread coolraj
Hi Julien ! I'm trying to import some data from txt file ( time and amplititude)I've imported the data but I'm struggling a bit to bring it into the table that you've created as a cluster , is it possible to set the inputs as two seperate float inputs. Thanks in advance Rajan

Re: Inherited reentrancy?

2004-04-24 Thread Ed Dickens
The thing you have remember is that even though there are only two instances of =91S=92 in the code of =91C=92, there are two instances of =91= C=92 (if set to reentrant) in the code for =91M=92. So each instance of =91C=92 will have its own data space within =91M=92, and as it loads its subVIs,

Remote panel behavior in built application differs from development app

2004-04-24 Thread crain
I frequently use the control.disabled property nodes to control how a user interacts with a GUI. It is crucial my application runs well via remote panels. I was delighted that these control properties (visible, disabled, etc) work in a remote panel, but built applications do not work properly.

Re: draw an angle

2004-04-24 Thread FerozP
Hi Thandal, Please take a look at the following posting a href=http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101RPAGEID=135HOID=5065000800F7CEUCATEGORY_0=_49_%24_6_UCATEGORY_S=0USEARCHCONTEXT_QUESTION_0=draw+an+angleUSEARCHCONTEXT_QUESTION_S=0; Draw an Angle /a Sincerely,

Re: How do I get a print dialog window ?

2004-04-24 Thread Joe Guo
Unfortunently there aren't many options except using windows API. -Joe

Control OpenOffice from LabVIEW

2004-04-24 Thread Faraclas
Does anyone know how to automate OpenOffice applications from LabVIEW?

Re: Limit to the sampling rate for an HP4192 Impedance Analyzer?

2004-04-24 Thread Swordfish78
I'm only doing measurement at a constant frequency, 100 Hz. And I am using the Averaging function on the keypad of the 4192. As for going on to the next measurement, I'm not using any control, that I know of. I (naively) assumed the instrument would make a new measurement with each increment of

how to get time stamp from Waveform chart ?

2004-04-24 Thread Nok
Hi..everybody I want to get the timestamp from the waveform chart/graph in order to save to file. Thanks in advance for any help.

Tab Control will not build properly if tab location are on left or right.

2004-04-24 Thread wilvil2000
Using LV 6.1, try the following; Create a new vi. Place a Tab control,(from the Arrays Clusters palette), on it's front panel. Right click on one of it's tabs and follow Advance--Tab Location--select Left. Save your vi. Create a build for it and run the program. Does anyone know of a fix for

Re: How do I save a mutlitcolumn data to a text file?

2004-04-24 Thread Dennis Knutson
All you need probably is two functions. Write Characters to File for titles and labels, and Write To Spreadsheet File for the data. You would have to use them each a couple of times. By that I mean write a couple of lines with the labels, write the data, write a couple of lines with new labels,

Re: How do I view input from a PCI TV card

2004-04-24 Thread LouisP
Hello, I would recommend the first web adress, personally, for what you are doing. You can download the vis direct from that site, at no charge. A text file come with the download, explaining how to populate the LabVIEW functions pallette with your newly downloaded vis. Kind Regards Louis Price

Re: is there an IVI Labview to manage PS/SC windows library?

2004-04-24 Thread Jabba
GEMPLUS, Apr=E8s v=E9rification, il n'exsite pas de driver Lv permettant de gerer les smartcard. Cependant, si vous possedez une DLL permettant de communiquer avec cette outil, il est possible d'appeler directement cette DLL dans LabVIEW. Dans le dossier \National

Re: how to perform envelope spectrum analysis in labview

2004-04-24 Thread JuanCarlos
Pavitra, I'm not very familiar with envelope spectral analysis; however there are a couple of links that I can recommend: a href = http://www.ni.com/industrial/;Industrial applications:/a This is a good colection of customer solutions and general information on machine monitoring, vibration,

Re: Tab Control will not build properly if tab location are on left or right.

2004-04-24 Thread Dennis Knutson
I was able to build and run a program following your instructions. I saw no problem. What do you mean by will not build properly? Do you get an error or what?

Re: How do I set a coordinate system using Vision Assistant 7.0

2004-04-24 Thread dmp
Vision Assistant does not currently have the ability to create coordinate systems. You can either generate LabVIEW code from your Vision Assistant script and insert the coordinate system VIs, or use Vision Builder for Automated Inspection to set up a coordinate system. Best regards, Dawna P.

Re: Tab Control will not build properly if tab location are on left or right.

2004-04-24 Thread wilvil2000
Are you saying that you are able to resize the tab control and then create an executable that displays correctly?

Re: Using GPIB to talk to HP4083A Switching Controller.

2004-04-24 Thread ScottieB
The forums seem to be working okay, I wonder if there is a firewall issue. You can upload the files to ftp.ni.com in the Incoming folder. Zip them up and name them BCLioness.zip and post here when you have done that and I'll take a look at them. Sorry for all the trouble. Scott

Re: Tab Control will not build properly if tab location are on left or right.

2004-04-24 Thread Dennis Knutson
I can't explain it either but if I resize the tab control by even a slight amount, the tabs get displayed correctly.

Re: how to get time stamp from Waveform chart ?

2004-04-24 Thread LarsRoe
Charts and graphs are indicators, so you have to look at it's source. If it is a waveform, use the waveform unbundler in the waveform palette.

Re: file size limitation?

2004-04-24 Thread unclebump
I ran into this same problem when using the database connectivity toolset. On a win2000 machine, the .mdb file size was limited to 1GB. I changed my DSC application to store the data in the CITADEL database. CITADEL handles all of the file naming and size issues internally.

Re: Using Numeric Integration.vi: Is this correct?

2004-04-24 Thread fahlers
Hi Don, I had a quick glance on your VI and the formula in it. This formula contains terms like fcc(taumax + tau) which IMO are meant to read: value of the (time dependent) function fcc at time (taumax+tau). In your code however you calculate the product fcc * (taumax + tau) which is of course

Re: Seeking LabVIEW drivers for Anritsu 37xxxC lightning VNA

2004-04-24 Thread Matt Moose
Hi all, Glad to say that it didn't take long for us to write a new driver! It's basically a wrapper around the sending of different GPIB command strings, with lots of room for alteration and expansion. Although there were plenty of specific VI's for the Anritsu 372xxA, we decided to write a

Re: How to turn off new LV7 Ring Control behavior?

2004-04-24 Thread CoastalMaineBird
p iyou will need to change both the Strings and Value property node. /ip Drat - that's the part that breaks my code. Well, it doesn't break , but it's now uglier than it used to be. Thanks for the info.

Re: Datalogging with campbell scientific CR23X

2004-04-24 Thread SarahM
Hey Jared, I would suggest starting by determining how you're going to communicate with your hardware. You'll need to have some way maybe through Serial or GPIB to communicate with the micrologger and the cirulator. I would get the communication working in LabVIEW and then move onto programming

Misubishi PLC control from LabVIEW via RS-232

2004-04-24 Thread Ed Dickens
I=92ve been tasked to build some VIs to control a Mitsubishi PLC that controls a Temp/Vibe chamber. The PLC series in question is on the OPC server support list, so that=92s not an issue. Since there are only a dozen items that I need to communicate with, I though I=92d try using Datasockets. The

Re: How do I get a print dialog window ?

2004-04-24 Thread Dennis Knutson
The LabVIEW tool for printing is the report generation functions. Why do you not want to use that. It can easily handle printing a single indicator. The other option is the transfer all data to a subVI that only has the single indicator and is set to print upon completion. This is settable from VI

Re: How do I get a print dialog window ?

2004-04-24 Thread Act
Thanks for the info Dennis. How do I interface with C-code through Call Library Function? And what is the difference between Call Library Function and Call Interface Node ? Thanks.

Re: XY Graph question

2004-04-24 Thread Victrick
Hmmm... It looks to me like you should be able to as if you'll look under XY Graph Properties-Plots, each plot has a drop-down list of items specifying the Y-Scale and X-Scale that the current plot is using. The only problem is, each list only contains a single item - either the current X-Scale

How accurate is the wait function when using really long waits?

2004-04-24 Thread Victrick
Howdy all, There was a similar earlier post asking about wait accuracy over small periods:

Subpanels?

2004-04-24 Thread Swinarsky, DJ Derrick (5453) @ IS
I was looking into using subpanels in an application that I am building. I want subpanels so that I can add new filetypes to the app at a later time without any problems. I was wondering about any pitfalls that I may find if I go with subpanels. The app will end up being an executable and that

Re: Edit Write LabVIEW measurement file header

2004-04-24 Thread jhoskins
hey bernd it's me again. What you will need to do if you want to use this Vi is place it on the block diagram. right click on it then select open front panel and then convert. Go to the block diagram and dig down in the vi until you find a Vi called ex_Headertospreadsheetstr open that up and save

Re: How do I get a print dialog window ?

2004-04-24 Thread Dennis Knutson
In the examples, all of that has already been done for you. All you have to do is use the provided VIs. However, if you wish to learn about calling DLLs and using CINs, Open the LabVIEW Bookshelf from the hlpe menu and open Using External Code in LabVIEW.

Re: I'm haveing a problem saving my test results to excel using the report generation toolkit.

2004-04-24 Thread kmoorthy76107
Hi Have you found a solution to your problem of saving excel spreadsheet data using Report Generation toolkit yet? If so, could you please post it here? I am trying to do the same thing and can't figure out how to save the excel data. Thanks in advance.

starting a terminal

2004-04-24 Thread striker
I am new to the industry and very new to labwindows. In my lab we use ProComm Plus, a terminal emulation application to control our hardware via serial connection to our PC's. We can write simple scripts to perform testing on our products, update our products, etc. I am looking for something in

Re: XY Graph question

2004-04-24 Thread Dennis Knutson
Right click on the Y scale and select Duplicate Scale. You can keep it on the left side or right click again on the scale you want and select Swap Sides. When you have a duplicate scale, the next thing to do is to associate that scale to a specific plot. In the plot legend, right click the plot

Missing VI Amplitude and Level Measurement

2004-04-24 Thread GuyBoogie
When I loaded the VI Example for Chapter 2 of getting started it won't let me run the program because its missing the amplitude and level measurement palette/VI. I was wondering how I could get it back?

Re: custom pulse train generation

2004-04-24 Thread Davediego
I guess I should have added that I'm using an E-series pci card (no PXI) with a BNC-2110 breakout box. I'll have to plead ignorance as to how to connect these signals, is this a software routing? Thanks for the help.

Re: Control OpenOffice from LabVIEW

2004-04-24 Thread Faraclas
Actually, I was refering to the OpenOffice.org suite (you know, the FREE office tools). I can control Microsoft products already but I would like to get away from them.

Need Help: How to design USB Driver for USBN9603

2004-04-24 Thread LabViewFreak
Hi, I want to communicate with this USB-Interface-Chip USBN9603 - http://www.farnell.com/datasheets/35246.pdf When I take a look at this tutorial http://zone.ni.com/devzone/conceptd.nsf/webmain/6792BAB18242082786256DD7006B6416?opendocument I have to know things like vendor ID, product ID,

Timing User Events With PCI NI 6503

2004-04-24 Thread GuyBoogie
I am a fairly new user to Labview and I would like to time an event. More specifically how would I be able to time (in ms) how long it takes a user to push a button on the hardware.

Necessary to make strange tweaks to my array data pointers when calling dlls

2004-04-24 Thread Nickster
In building pointers to be passed to certain dll calls, I have noticed that I need to pay attention to some peculiar details if I want the functions to execute properly. Namely, numeric types must have their bytes reversed from the way in which LabVIEW orders them (least-significant last) before

Re: Missing VI Amplitude and Level Measurement

2004-04-24 Thread Dennis Knutson
Chances are you only have the base package and this is only included with the Full version and up. If this isn't mentioned in the instructions, then I suggest contacting NI directly and mentioning that the manual needs to be corrected.

Re: custom pulse train generation

2004-04-24 Thread Davediego
actually the card is a PCI-MIO 16E-1. On a PXI-6025E that we have, I see that there are hardware connections for all the aforementioned signals. I don't think the gates are available on the 16E-1 combined with the BNC-2110. So is such a trigger possible with my setup or should I be using some

Re: LV GOOP

2004-04-24 Thread Christopher Relf
G'Day Dan, Have a look at the LabVIEW config file VIs (FunctionsFile I/OConjuration File Vis) - they were created using OOP principles. Probably one of the most important Vis you want to look at in their hierarchy is Config Data Registry - this is the structured LV2-Style global that acts as the

Running VI from another VI

2004-04-24 Thread Shreesha
HI, I have program1.vi running. When a user clicks on a button, Program2.vi needs to be launched. The way I am doing it now, is by calling Program2 in Program1; so program2 acts as a subVI. But I have a problem here..I dont want my Program1 to be running, when Program2 is

Re: Edit Write LabVIEW measurement file header

2004-04-24 Thread Bernd R.
Hey Joe, thanks for your answer. Unfortunately I'm not able to find that VI anywhere. If you could help me find it, that would be great. I wire it then to the converted Write LVM VI, right? Bernd

Modifying cluster values via refnum/property node freezes VI on quit

2004-04-24 Thread apocow
I just learned how to use property nodes and refnums to modify the values of individual controls inside of a type-defined cluster. But when I incorporate this into an existing and working VI, a weird thing happens: the VI works exactly as it should when it is running, but when I quit the VI, the

New Zealand NI Support ( was Buying LabVIEW abroad )

2004-04-24 Thread Christopher Relf
G'Day Mihai, As far as I'm aware, although there is no longer a physical NI NZ office, NI still has a FSE (Archie Garcia) on the ground parttime in NZ. That said, I'm sure that you're always welcome to either chat to Archie when he's not in NZ, and/or someone here at Neo Vista System

Re: How accurate is the wait function when using really long waits?

2004-04-24 Thread shoneill
I don't know about accuracy, but I noticed something funny last week while running a program. I have a program which communicates over RS-232 and I need to make pauses now and then. After sending a few commands, I set the VI to wait for 20 minutes (120 ms). If I call the 20 minutes, half

Vision: Color of frame when moving ROI

2004-04-24 Thread Peter Prinzen
Hi, I want to adjust the color of an ROI, when it is moved by the user. Normally it will be white, but I want a more visible color, like red: (it's a b/w picture, where you don't see the roi during moving). TIA Peter

Re: Acquire N Scans doesn't work

2004-04-24 Thread shoneill
I only have the evaluation version of LV 7 on my computer, and I don't have any DAQ installed for it. Therefore, I can't test the program. I have seen, however, that you send 0 to the parameter for number of scans for the AI Start function. Is this correct for continuous scans, or should this

Re: Acquire N Scans doesn't work

2004-04-24 Thread Giulia
The question is: have you ever heard that some DAQ VI don't work if input signal is too low? It seems quite strange.

Re: NI DMM 4060/4070 voltage and current measurement

2004-04-24 Thread Uwe Frenz
Naveen, you asked on Wed, 14 Apr 2004 12:02:42 +0530: We are planning to build a test system for testing a power supply module. Power supply module has 10 outputs ranging from 5V to 24V We are planning to use a single NI DMM 4060 / 4070. and a switch multiplexer (SCXI 1127 as there are some

can I change the supported data types of the ODBC toolkit

2004-04-24 Thread rsscan
I have a string of 39KB that I want to store into a SQL server 2000 table. The defined field in the table is text because a nvarchar type can only store up to 8KB. The problem now is that the NI ODBC toolkit converts a LabVIEW string into a varchar field (see supported data types). That's why

Re: Acquire N Scans doesn't work

2004-04-24 Thread shoneill
The only thing I can imagine is if the input range is set too high (The gain too low) so that the resolution is too low to detect any better then +- 0.465V. +-0.465 V is a HUGE threshold if this has anything to do with resolution! Are you sure it's Volt, and not Millivolt? Shane.

Re: editing analog waveforms (amplititude)using mouse

2004-04-24 Thread jumarion
In LabVIEW's examples - Key word : Waveforms - Lots of VI's could be intersting for you (Noise waveforms and PS Density.vi for instance). Feel free to refer as much as possible to those examples. They often show you how to develop things. That's all I can tell you Hope this helps ! Julien

  1   2   3   4   >