Re: [Nut-upsdev] Tripplite Smart Int 1000 - wrong numbers

2017-10-10 Thread tuharsky
We might need to get some results from others who have similar hardware, but 120V wiring, and compare to see if one of the digits refers to the voltage range. Well, I don't know any... And I don't see voltage selector on UPS either. ___ Nut-upsdev

Re: [Nut-upsdev] Tripplite Smart Int 1000 - wrong numbers

2017-10-10 Thread Charles Lepple
On Oct 10, 2017, at 11:50 AM, Thomas Charron wrote: > > I do have some of the more modern protocol documentation for Tripplite from > the tripplite engineers, if someone is working on updating the Tripplite > drivers. Is this something we can publish on the protocol

Re: [Nut-upsdev] Tripplite Smart Int 1000 - wrong numbers

2017-10-10 Thread Charles Lepple
On Oct 10, 2017, at 1:37 AM, tuhar...@misbb.sk wrote: > > Charles, maybe we are getting closer :-) >> The tripplite_serial_protocol branch has some debug statements that will >> show up if you run "sudo drivers/tripplite -D -a name-of-ups" from the nut >> directory. > Network UPS Tools -

Re: [Nut-upsdev] Tripplite Smart Int 1000 - wrong numbers

2017-10-10 Thread Thomas Charron
I do have some of the more modern protocol documentation for Tripplite from the tripplite engineers, if someone is working on updating the Tripplite drivers. Their protocols are horrible. Thomas On Tue, Oct 10, 2017 at 1:37 AM, wrote: > Charles, maybe we are getting