Re: [Nut-upsdev] [HCL] Riello IPG 600 supported by riello_usb / incorrect battery.charge and ups.temperature values

2017-11-21 Thread Charles Lepple
[when responding, please use Reply-All to include the list. Thanks!] On Nov 16, 2017, at 6:30 AM, Andrés Valdaliso wrote: > > Hello everyone, > > I recently bought a Riello IPG 600 UPS > (http://www.riello-ups.com/products/1-ups/39-iplug) to prevent hardware > damage to

[Nut-upsdev] [HCL] Riello IPG 600 supported by riello_usb / incorrect battery.charge and ups.temperature values

2017-11-16 Thread Andrés Valdaliso
Hello everyone, I recently bought a Riello IPG 600 UPS ( http://www.riello-ups.com/products/1-ups/39-iplug) to prevent hardware damage to my server in case of power outages (already lost two hard drives because of this) and I managed to successfully configure it with NUT version 2.7.4 available