Hi Prem,
From the error message, this is within the automated analysis for
relaxation dispersion. Creating the data pipe 'R2eff - relax_disp
(Mon Nov 17 10:50:08 2014)' can only happen once, as the 'R2eff' model
is only optimised once (there is a loop over all models). There is
only one thing I
Hello Troels and Edwards,
The modified tutorial that you sent me worked fine.
Looks like I might have done some mistake while setting up the run using
the original GUI tutorial for relaxation dispersion. I will try the
original tutorial again to make sure the setup was fine. if the error still
Hello Edward,
I tried the GUI version of the setup again for the relaxation dispersion
(on the test data) and it ran without any error this time. Its possible I
made some mistake during the setup thr last time.
Thank again for the help
Prem
On Tue, Nov 18, 2014 at 5:27 AM, Edward d'Auvergne
Hi Prem.
I added the tutorial here:
http://wiki.nmr-relax.com/Tutorial_for_The_relaxation_dispersion_auto-analysis_in_the_GUI
I tried to take power of the scripting, to get around the tedious work on
defining the experiment settings for all spectra.
So this script should take you to the end
Hi Troels,
For the tutorial at
http://wiki.nmr-relax.com/Tutorial_for_The_relaxation_dispersion_auto-analysis_in_the_GUI
, I would suggest also adding that relax can be run using OpenMPI to
speed up the relaxation dispersion analysis. So that if you have a
machine with 8 cores and OpenMPI and