[sane-devel] [PATCH] Progress on HP2400 (genesys backend)

2011-06-08 Thread Alexey Osipov
. -- next part -- A non-text attachment was scrubbed... Name: genesys-hp2400-50_150_600_1200dpi.patch Type: text/x-patch Size: 5164 bytes Desc: not available URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110608/078f1bff/attachment-0002.bin -- next part

[sane-devel] Meldung: Operation abgebrochen

2011-06-08 Thread Olaf Meeuwissen
Please keep this on the mailing list. That way it will get archived and be searchable for everyone. gilada at web.de writes: Am Tuesday 07 June 2011 02:19:37 schrieben Sie: Wolfram Heider wolframheider at web.de writes: On Mon, 06 Jun 2011 23:20:57 +0200, Jeffrey Ratcliffe

[sane-devel] Problem using SX410 scanner - Invalid argument error

2011-06-08 Thread Olaf Meeuwissen
Please keep this on the mailing list. That way it will get archived and be searchable for everyone. Steffan Harris scisteffan at gmail.com writes: On 06/06/11 00:46, Olaf Meeuwissen wrote: Steffan Harrisscisteffan at gmail.com writes: I'm getting invalid argument errors when trying to run

[sane-devel] Gt-30000 and epkowa - Was Fwd: sanner still jogs - more buffering ?

2011-06-08 Thread Olaf Meeuwissen
Please keep this on the mailing list. That way it will get archived and be searchable for everyone. Pete Lancashire pete at petelancashire.com writes: Here's the logs and some more information Your logs indicate that the epkowa backend is not limiting the size of its internal buffer to 32kb,

[sane-devel] Recent NM-1000

2011-06-08 Thread stef
Le mardi 7 juin 2011 23:18:45 Paul Ericson, vous avez ?crit : Here is my USB snoop file. Hello, the log is in a binary format, so I need to know the tool you used to read it. Logging a scan at low resolution would give us the best information on the chipset used in this

[sane-devel] Gt-30000 and epkowa - Was Fwd: sanner still jogs - more buffering ?

2011-06-08 Thread Olaf Meeuwissen
Pete Lancashire pete at petelancashire.com writes: with the change made below, and setting the SANE_SG_BUFFER_SIZE to 1 Meg the scanner jogs 2 times and takes 15.21 (avg of 3 passes) seconds, That's 214,812,000 bytes / 15.21 seconds = 14,123,076 bytes/sec, or about 14.1MB/s. How much closer

[sane-devel] [PATCH] Progress on HP2400 (genesys backend)

2011-06-08 Thread Alexey Osipov
. Regards, Alexey. -- next part -- A non-text attachment was scrubbed... Name: hp2400-1200dpi-progress.patch Type: text/x-patch Size: 2643 bytes Desc: not available URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110608/7bf2ddf2/attachment.bin

[sane-devel] Meldung: Operation abgebrochen

2011-06-08 Thread gil...@web.de
Am Wednesday 08 June 2011 01:33:18 schrieben Sie: Please keep this on the mailing list. That way it will get archived and be searchable for everyone. gilada at web.de writes: Am Tuesday 07 June 2011 02:19:37 schrieben Sie: Wolfram Heider wolframheider at web.de writes: On Mon, 06 Jun

[sane-devel] Gt-30000 and epkowa - Was Fwd: sanner still jogs - more buffering ?

2011-06-08 Thread Pete Lancashire
My goal is something close to the advertised speed (8.058 seconds per page). I would be happy with say 10 seconds which is 24% slower. Would be OK at say 12 seconds which is almost 50% slower. Will 15 to 17 seconds work, yes. but 85% to 120% slower then advertised really hurts when ones ability

[sane-devel] Gt-30000 and epkowa - Was Fwd: sanner still jogs - more buffering ?

2011-06-08 Thread Pete Lancashire
Let me add to what I said Will 15 to 17 seconds work, yes. but 85% to 120% slower then advertised really hurts when ones ability to win contracts is based on ones reputation. I was asked to come up with a solution to scanning documents. I 'sold' the idea of using Linux and the GT-3. I

[sane-devel] Information from about Plustek Optic Slim 2400+

2011-06-08 Thread m. allan noah
That machine is listed as 'good' in recent versions of sane-backends. You should not have to add anything to the config file? http://www.sane-project.org/cgi-bin/driver.pl?manu=model=bus=anyv=07b3p=0454 allan On Wed, Jun 8, 2011 at 3:17 PM, Rados?aw Smogura mail at smogura.eu wrote: I've seen

[sane-devel] [genesys] canon lide 210: scans contain circles

2011-06-08 Thread Jiri Slaby
Hi, I've just bought a Canon Lide 210 scanner. So I've enabled genesys driver and ran xsane. I did no calibration as described in the manpage as there is no cal sheet and no --calibrate option for scanimage. So I took a preview and did a real scan then. But after scanned, the picture contains

[sane-devel] [genesys] canon lide 210: scans contain circles

2011-06-08 Thread m. allan noah
Those circles are called half-toning. Look at your original paper with a magnifier, and you will see them. allan On Wed, Jun 8, 2011 at 3:22 PM, Jiri Slaby jirislaby at gmail.com wrote: Hi, I've just bought a Canon Lide 210 scanner. So I've enabled genesys driver and ran xsane. I did no

[sane-devel] [genesys] canon lide 210: scans contain circles

2011-06-08 Thread Jiri Slaby
On 06/08/2011 09:34 PM, m. allan noah wrote: Those circles are called half-toning. Look at your original paper with a magnifier, and you will see them. Yes, you are right. Sorry that I didn't notice earlier. As I know what's that now, I tried to google a bit without any good results. I only

[sane-devel] Project front end

2011-06-08 Thread Tiago Zaniquelli
-- An HTML attachment was scrubbed... URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110608/8684c9be/attachment.html

[sane-devel] Project front end

2011-06-08 Thread Tiago Zaniquelli
-- An HTML attachment was scrubbed... URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110608/79e5d6fc/attachment.html