[sane-devel] unclear error message

2011-07-11 Thread Olaf Meeuwissen
Hi Jeremy, I saw on the list that you've already got the scanner to work with the newer sane-backends-1.0.22. Good. The epson2 backend in 1.0.21 had a couple of pretty bad show-stoppers :-( Hope this helps, -- Olaf Meeuwissen, LPIC-2 FLOSS Engineer -- AVASYS CORPORATION FSF

[sane-devel] Fix for infinte for loop

2011-07-11 Thread stef
Le samedi 9 juillet 2011 11:05:56 Hans Petter Selasky, vous avez ?crit : On Saturday 09 July 2011 06:38:27 stef wrote: Le vendredi 8 juillet 2011 11:09:15 Hans Petter Selasky, vous avez ?crit : --- /sane-backends-1.0.21/backend/genesys_gl646.c.orig2011-07-08 11:07:05.0 +0200

[sane-devel] CanoScan 700F

2011-07-11 Thread stef
: not available URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110711/3e029827/attachment.bin

[sane-devel] CanoScan 700F

2011-07-11 Thread Brad Laue
-- An HTML attachment was scrubbed... URL: http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20110711/c537552f/attachment.html

[sane-devel] Reflecta ProScan 7200

2011-07-11 Thread Michael Rickmann
Hi Jan, sorry for the very late reply. I have been rather busy with different things and have not done very much on the PIE backend. Am 02.06.2011 21:37, schrieb Vleeshouwers, J.M.: Hi Michael, large snip wait loops for the device to get ready. I (accidently) noticed that the

[sane-devel] Dust removal inSANE ?

2011-07-11 Thread Michael Rickmann
I learned from other posts in this list that SANE does not provide much support for infrared. In sane.h some related definitions are even commented out. Only in coolscan.c I have found some RGBIfix routines by Andreas Rick which must be related to what he describes on his page at

[sane-devel] Dust removal inSANE ?

2011-07-11 Thread m. allan noah
Excellent description of both the problem, and the solution. I wrote sanei_magic to contain exactly these sort of routines. Though, you could also add a sanei_ir or some such, if you want a more 'private' playground :) allan On Mon, Jul 11, 2011 at 12:54 PM, Michael Rickmann mrickma at gwdg.de

[sane-devel] CanoScan 700F

2011-07-11 Thread stef
Le lundi 11 juillet 2011 13:45:25 Brad Laue, vous avez ?crit : On 07/11/11 01:22, stef wrote: Le samedi 9 juillet 2011 13:22:55 Sebastian Reinhardt, vous avez ?crit : Am 26.05.2011 06:56, schrieb stef: Hello, I'm currently completing 2400/4800 dpi support for LiDE 200. I bug

[sane-devel] sanei_usb problems when using libusb_1.0 with hp3670

2011-07-11 Thread stef
Hello, I have a scanner with only one usb configuration. Using usb_set_configuration on it will result on a failed usb call. So to avoid problem I moved all the usb_set_configuration and the result testing within the case where dev-descriptor.bNumConfigurations 1 . Then if I

[sane-devel] sanei_usb problems when using libusb_1.0 with hp3670

2011-07-11 Thread stef
Le lundi 11 juillet 2011 22:28:00 stef, vous avez ?crit : Hello, I have a scanner with only one usb configuration. Using usb_set_configuration on it will result on a failed usb call. So to avoid problem I moved all the usb_set_configuration and the result testing within the case