Hello,
I have disabled power saving for GL646 based scanners in CVS, as it is
certainly the cause of your problems. This was overwritting some per model
CCD settings that aren't reset later, leading to 'black scans'.
Could you please test CVS version ?
Regards,
Hi list,
I'm currently working on the support of a sheet-fed device
and this seem to work well up to the point where the calibration
stage needs to be done, as the calibration is equal to scanning
an extra calibration sheet...
It seems, that apart from the normal scan operation, I need a special
Hello,
On Feb 7 21:32 Till Kamppeter wrote (shortened):
The usblp module can be replaced by a libusb-based CUPS backend.
Download
http://www.linuxprinting.org/till/tmp/usb-libusb.c
...
The libusb-based CUPS backend is written by Couriousous, a Mandriva
contributor, thanks to him for
Johannes Meixner wrote:
Hello,
On Feb 7 21:32 Till Kamppeter wrote (shortened):
The usblp module can be replaced by a libusb-based CUPS backend.
Download
http://www.linuxprinting.org/till/tmp/usb-libusb.c
...
The libusb-based CUPS backend is written by Couriousous, a Mandriva
Dear list, and members
I would to know how much it would cost to develop a backend for the CanoScan
Lide 500F
I can lend the scanner for this mission.
Backend would be reverse to the sane project.
Thanks if someone could send me an offer at email below.
--
Bruno Friedmann