if you scan with a higher dpi, there is more data to display. it may be
possible for a front-end to be smart enough to scale the image to fit on
your screen no matter the dpi, but this really has nothing to do with
sane. i know for instance, that gqview has options to do just this...
allan
I'm trying to test my Canon LIDE50 scanner with the latest CVS, but all
the scanner does is flash pink, then red, then yellow quickly, then a
continuous white.. Is there anything obvious i'm doing wrong?
Cheers
Ash
I've managed to get sane/xsane working with my Canon LiDE 60.
I did this by compiling the experimental CVS genesys
backend (including Pierre's recent support for the LiDE35/40/50).
Before compilation I replaced every instance of the LiDE 35
USB ID (0x2213) with the USB ID for the LiDE 60
Hi all,
i just wanted to let you know that i finally got the coolscan V working
with Sane :-)) it took a while because the docu is quite twisted to
understand.
I still don't have a patch to provide, because i hardcoded some parameter,
but will get in touch with Andras to get something usable
this is great.! Congrats. Now, how about the NIKON LS-5000? I am waiting
for your driver so that I can start my project, hopefully. Any idea of
where you are at so far?
Hopefully the LS-5000 will work also with the same fixes, didn't check the
specs though, but you'll get to test the patch
Hi,
yes, that seems to be a bug. I'll put you patch into to cvs
the next days.
Tanks
Oliver
Am Donnerstag, 6. Oktober 2005 21:11 schrieb Stefanie Tellex:
Hi,
I think I fixed the problem. The SCSI read was returning EOF, and the
driver wasn't incrementing its buffers properly in that case.
When scanning at high resolutions or bit depths, my scanner shoe
shines a lot. I once read about a /proc/scsi trick to increase
some buffer size and avoid the shoe-shining but I can't find it
now. Any ideas ?
Linux 2.6.13, HP ScanJet C7670A on a cheap DC-390 Tekram (AMD
AM53C974).
Thanks in
Olaf Meeuwissen wrote:
Henning Meier-Geinitz henn...@meier-geinitz.de writes:
Hi,
If scanimage works and the gui frontends don't, the usual cause is
that you have two installations of sane-backend on your system. One is
the one you compiled yourself (in /usr/local/...). This one is used by
Hi list,
If one of the folks with write access to CVS would be so kind to
commit the attached diff for doc/external-descriptions/epkowa.desc,
I'd be grateful.
After the commit #302183 can probably be closed.
--
Olaf Meeuwissen
FSF Associate Member #1962 sign up at
[Third attempt to post to sane-devel. Will it work or will it not ?]
When scanning at high resolutions or bit depths, my scanner shoe
shines a lot. I tried setting SANE_SG_BUFFERSIZE to various values
between 500 kB and 5 MB but it didn't make any difference. Any
ideas ?
Linux 2.6.13, HP ScanJet
/pipermail/sane-devel/attachments/20051017/1a546d70/attachment.htm
From lno...@dragon.unideb.hu Mon Oct 17 13:09:32 2005
From: lno...@dragon.unideb.hu (Levente =?ISO-8859-1?Q?Nov=E1k?=)
Date: Mon Oct 17 16:15:22 2005
Subject: [sane-devel] EPKOWA Epseon PF 3590 Photo
In-Reply-To: 877jcf109b
Have you some drive for scanner Enhans J6131?
Thank you
trezzi.lu...@tiscali.it
-- next part --
An HTML attachment was scrubbed...
URL:
http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20051017/a103f285/attachment.html
From lno...@dragon.klte.hu Mon Oct 17
As I was looking at the code, I noticed that several others of the
reader processes in the fujitsu driver have the same sort of bug. My
scanner isn't invoking them so I didn't write a patch since I can't test
it. But it looked like color and duplex scanners might run into it too.
Thanks,
Hi,
On Mon, Oct 17, 2005 at 01:16:03PM -0400, Patrick Lessard wrote:
I own a Astra 2100U and as everyone knows, compatibility is almost complete
with this model.
Well, status is minimal.
I would like to try to help solving the color problem.
Sounds good. Helps means that you must write a
Hello,
Thanks for your answer. Rest of the answers are inline.
-Message d'origine-
De : sane-devel-boun...@lists.alioth.debian.org
[mailto:sane-devel-boun...@lists.alioth.debian.org]De la part
de Henning
Meier-Geinitz
Envoy? : 17 octobre, 2005 13:30
? :
Hi,
On Mon, Oct 17, 2005 at 11:26:32AM +0100, Jim MacLeod wrote:
Really basic question -
how can I link or copy or install the new cvs backend so that the front-ends
can find it. Removing libsane package takes out all the graphics front-ends
because of dependencies.
The clean way would be to
Hi,
On Mon, Oct 17, 2005 at 12:09:57AM +0200, Franz Bakan wrote:
Sorry, but mustek_usb2 backend is not disabled after your latest
patches,
Next time I'll really read the autocond documentation. This should be
fixed now. And the output of configure is also a bit more clear.
You are a good bug
Hi,
On Sun, Oct 16, 2005 at 06:15:24PM -0400, Fred Odendaal wrote:
Yes, I'm also quite surprised. It works fine with xscanimage, but
doesn't when I use xsane. So I compared the debug output.
Strange. Maybe Oliver Rauch can comment on this?
Does the gt68xx backend report back the true x and
Hi,
On Sun, Oct 16, 2005 at 11:11:05PM +0200, Benjamin Mirza wrote:
Sane-find-scanner output: 0x04f9 0x0161
libsane.usermap entry:
# Brother|MFC 210C
libusbscanner 0x0003 0x04f9 0x0161
0x 0x 0x00 0x00
0x000x00
Hi,
On Mon, Oct 17, 2005 at 03:06:13PM +0930, Ashley Caire wrote:
I'm trying to test my Canon LIDE50 scanner with the latest CVS, but all
the scanner does is flash pink, then red, then yellow quickly, then a
continuous white.. Is there anything obvious i'm doing wrong?
Just to be sure: You
Hi,
On Mon, Oct 17, 2005 at 08:44:35PM +0900, Olaf Meeuwissen wrote:
If one of the folks with write access to CVS would be so kind to
commit the attached diff for doc/external-descriptions/epkowa.desc,
I'd be grateful.
Thanks. It's in CVS now.
After the commit #302183 can probably be
Hi,
On Mon, Oct 17, 2005 at 12:09:41PM -0400, Rayudu Addagarla wrote:
when one uses adf scanner.
what does a backend return the each page is done.
say i use, scanadf -s1 -e3
After each page is done a backend returns what SANE_STATUS??
IIRC, the frontend just tries to scan (sane_start) and
/attachments/20051017/7e573ed9/r.h.h.koot.vcf
From henn...@meier-geinitz.de Mon Oct 17 19:54:54 2005
From: henn...@meier-geinitz.de (Henning Meier-Geinitz)
Date: Mon Oct 17 19:56:16 2005
Subject: [sane-devel] scanjet 7650
In-Reply-To: 43539a50.5060...@med.uu.nl
References: 43539a50.5060...@med.uu.nl
Am Mon, 2005-10-17 um 19.58 schrieb Henning Meier-Geinitz:
Hi,
On Sun, Oct 16, 2005 at 06:15:24PM -0400, Fred Odendaal wrote:
Yes, I'm also quite surprised. It works fine with xscanimage, but
doesn't when I use xsane. So I compared the debug output.
Strange. Maybe Oliver Rauch can
Hi,
On Mon, 17 Oct 2005 19:49:47 +0200, Henning Meier-Geinitz wrote:
Sorry, but mustek_usb2 backend is not disabled after your latest
patches,
Next time I'll really read the autocond documentation. This should be
fixed now. And the output of configure is also a bit more clear.
Works now as