Hello all,
Scanner: hp scanjet 2400
using sane-backends-cvs20051124
Expected completion date: unknown, it is ready when it is ready
Update from previous post:
key: - previously reported; + update :
- Head moves two times the expected distance.
- Excessive time in genesys_warmup_lamp()
+
Johannes Meixner jsm...@suse.de writes:
Hello,
On Nov 30 18:52 Chris AtLee wrote (shortened):
... if the usblp module is claiming the device and won't let
sane access it.
See the
Epson CX3200's scanner isn't detected with recent
thread on the sane-devel mailing list:
Hi everyone,
I did some tests with the LiDE 60 and the current CVS backend
(20051204-14:10). These are my results:
Lineart:
75: ok
150: ok
300: ok
600: ok
1200: ok
2400: freeze after 6 cm
Gray/8 bit
75: ok
150: ok
300: ok
600: ok
1200: freeze after 4 cm
2400: freeze after 1.5 cm
Gray/16 bit
Hi,
On Sun, Dec 04, 2005 at 02:19:36PM +0100, Reinhard Mayr aka Czerwinski wrote:
I did some tests with the LiDE 60 and the current CVS backend
(20051204-14:10). These are my results:
Use the backend from experimental CVS. As mentioned in my success
report, that one works much better
Progress report on CanoScan 3200F
-
Week ago I managed to get scanning working at 300 dpi with
no processing on in the scanner chip. That's raw 8 bit data
gray scale with no gamma or black/white shading. The experimentation
led me to study in detail the meanings of
Hello Denis,
I'm new to these mailing lists, so I hope I mail this alright.
I had the same problem like you, though before my 3490 I was struggling
to make an old canon scanner working with Xsane and learned a bit..
1: look into /etc/sane.d/dll.conf
Mine missed an entry to epkowa.conf which is
:19:36PM +0100, Reinhard Mayr aka Czerwinski
wrote:
I did some tests with the LiDE 60 and the current CVS backend
(20051204-14:10). These are my results:
Use the backend from experimental CVS. As mentioned in my success
report, that one works much better, at least for me.
Gray/16 bit
75: ok
Le Dimanche 4 D?cembre 2005 22:54, Oliver Schwartz a ?crit?:
Is there anything I can do to help get the Transparency unit to
work?
As far as I know the transparency unit of the 3490 works ok. The only
thing not supported is the automatic film feeder of the 3590. Please
make sure you use