[sane-devel] Compile error on latest CVS

2008-02-24 Thread Giuseppe Sacco
Hi all, it has been a few months I do compile sane from CVS, but now I am investigating about this[0] bug, so I started again. When I configure and make I use these commands: $ ./configure --prefix=/usr/local BACKENDS=snapscan $ make but the process stop this way: [...] epkowa.desc: Warning:

[sane-devel] Compile error on latest CVS

2008-02-24 Thread Giuseppe Sacco
Hi again, Il giorno dom, 24/02/2008 alle 09.18 +0100, Giuseppe Sacco ha scritto: Hi all, it has been a few months I do compile sane from CVS, but now I am investigating about this[0] bug, so I started again. [...] It seems I forgot to provide a link to the bug: http://bugs.debian.org/cgi-bin

[sane-devel] Problem in detecting usb scanner

2008-08-03 Thread Giuseppe Sacco
Hi all, I am testing once again a new linux kernel for mips architecture (both 2.6.26-rc9 and 2.6.26.1). On this machine (SGI O2) I am trying an usb scanner (epson perfection 1670) without luck, but I suspect something is missing among kernel modules. currently installed SANE is giuseppe at

[sane-devel] Problem in detecting usb scanner

2008-08-04 Thread Giuseppe Sacco
Il giorno dom, 03/08/2008 alle 23.23 +0200, Wolfram Heider ha scritto: Giuseppe, silly question: did you specify the location of the firmware (is required by the backend for the Epson Perfection 1670 as far as I know)? Yes I did it. I am thinking about a kernel problem because of this

[sane-devel] Problem in detecting usb scanner

2008-08-04 Thread Giuseppe Sacco
On Mon, 4 Aug 2008 14:30:20 +1000 Nick Andrew nick at nick-andrew.net wrote: [...] finally, why lsusb does not list the scanner? giuseppe at sgi:~$ sudo lsusb Password: Bus 003 Device 001: ID 1d6b:0001 Bus 002 Device 001: ID 1d6b:0001 Bus 001 Device 001: ID 1d6b:0001 This

[sane-devel] Problem in detecting usb scanner

2008-08-04 Thread Giuseppe Sacco
Hi Allan, On Sun, 3 Aug 2008 18:18:39 -0400 m. allan noah kitno455 at gmail.com wrote: the location of usb device files has moved from /proc/bus/usb to /dev/usb. perhaps your version of libusb looks in one place, and the system makes them in the other. udev might also be involved? The

[sane-devel] Problem in detecting usb scanner

2008-08-05 Thread Giuseppe Sacco
On Mon, 4 Aug 2008 11:24:46 +0100 Maurice McCarthy manselton at googlemail.com wrote: Giuseppe I'm running Debian unstable and lsusb is contained in usbutils: % lsusb -V % lsusb (usbutils) 0.73 I made a few more tests and reported a bug against liusb package:

[sane-devel] Scanning for fax - resolution problem

2009-01-08 Thread Giuseppe Sacco
Il giorno gio, 08/01/2009 alle 14.27 +0200, Frank Millman ha scritto: Hi all [...] scanimage --mode Gray --resolution 200 --format tiff -x 215 -y 297 | sendfax -n -m -d 1234567 Is your fax really able to transmit grey images? I suggest you to scan in black and white and/or to increase dpi.

[sane-devel] Fujitsu FI-5110C vs FI-6130

2009-01-24 Thread Giuseppe Sacco
Il giorno ven, 23/01/2009 alle 16.56 -0500, m. allan noah ha scritto: [...] Yes- they are expensive, but worth it if you are plan to keep it for a long time or do a great deal of scanning. If your needs are a little less, you might be able to find the previous model (fi-5120C) around on

[sane-devel] access right on multifunction devices

2009-03-23 Thread Giuseppe Sacco
Hi all, I am using sane on hp multifunction device, i.e., HP Photosmart C4180 All-In-One. I currently use this device for printing, while I am starting using it for scanning. Every time I plug its cable, udev load the driver and set authorisations for device /dev/bus/usb/$HUB/$DEVICE. Those auths

[sane-devel] ADF detection

2006-03-14 Thread Giuseppe Sacco
Hi all, I am facing a problem when I use many different scanners. I need to know if the scanner source currently used in a scan is ADF or flatbed. I noticed that different backends use different names like FB, Flatbed, ADF, Automatic Document Feeder. Is there any way to know that ADF is

[sane-devel] ADF detection

2006-03-17 Thread Giuseppe Sacco
Henning Meier-Geinitz ha scritto: Hi, On 2006-03-14 14:22, Giuseppe Sacco wrote: I am facing a problem when I use many different scanners. I need to know if the scanner source currently used in a scan is ADF or flatbed. Why? Because in this case I have to loop between all received

[sane-devel] Nikon CoolScan IV and next sane release

2006-04-26 Thread Giuseppe Sacco
Is there any chance the next sane-backends release will include the patch for supporting CoolScan IV (LS-50 ED)? This patch was proposed before the current release was prepared and it was never changed/updated. The patch still have some problem, but it works for colour negative film. Bye,

[sane-devel] Nikon CoolScan IV and next sane release

2006-05-08 Thread Giuseppe Sacco
Il giorno dom, 07/05/2006 alle 20.31 +0200, Henning Meier-Geinitz ha scritto: Hi, On 2006-04-26 10:45, Giuseppe Sacco wrote: Is there any chance the next sane-backends release will include the patch for supporting CoolScan IV (LS-50 ED)? I haven't seen any response from the backend

[sane-devel] Fujitsu backend update 7

2006-05-12 Thread Giuseppe Sacco
Il giorno ven, 05/05/2006 alle 00.51 -0400, m. allan noah ha scritto: I have released the next version of the updated fujitsu sane backend to my personal website. http://www2.pfeiffer.edu/~anoah/fujitsu/ up7 is a minor update to the up6 version (which works pretty well): [...] I just tried

[sane-devel] Nikon LS50

2006-05-13 Thread Giuseppe Sacco
Hi Ariel, about seven months ago you sent a patch against the coolscan2 sane driver. Color slides were working right, while negative films weren't. Basically it seems that '--negative' option was always inactive. Today I made new tests: if i run scanimage using --negative=yes option then I get an

[sane-devel] Fujitsu backend update 7

2006-05-13 Thread Giuseppe Sacco
Hi Allan, [...] fi-4010CU, sane-find-scanner list it as found USB scanner (vendor=0x04c5, product=0x1029) at libusb:002:003 this one is probably not a fujitsu, but i cant tell from your logs, try adding the usb ids to the fujitsu.conf, and get a debug log with just SANE_DEBUG_FUJITSU=30

[sane-devel] Nikon CoolScan IV and next sane release

2006-05-13 Thread Giuseppe Sacco
Hi, another problem I think I found on this patch is at about line 1525 of the patched file, where it is i = (xfer_len_in 0x3f); while it should be i = (xfer_len_in 0x3f); with a single ampersand. Bye, Giuseppe

[sane-devel] Fujitsu backend update 7

2006-05-16 Thread Giuseppe Sacco
Hi Allan, I recompiled today cvs (it should include your latest work; am I correct?) and installed it. I had to manually add the line usb 0x04c5 0x10e0 to fujitsu.conf since it was missing. Then I made some scan with this fujitsu fi-5120C. The program never crashed and the image was quite good

[sane-devel] Fujitsu backend update 7

2006-05-16 Thread Giuseppe Sacco
Il giorno mar, 16/05/2006 alle 15.10 -0400, m. allan noah ha scritto: On Tue, 16 May 2006, Giuseppe Sacco wrote: [...] I had to manually add the line usb 0x04c5 0x10e0 to fujitsu.conf since it was missing. it is in the default config file that comes with the backend. if you had to add

[sane-devel] Fujitsu backend update 7

2006-05-16 Thread Giuseppe Sacco
Il giorno lun, 15/05/2006 alle 12.55 +0200, Rene Rebe ha scritto: On Saturday 13 May 2006 20:53, Giuseppe Sacco wrote: fi-4010CU Most probably Avision. Can you try adding the ID into the avision backend and give it a try? A USB snoop of the window driver would be nice as well. $ env

[sane-devel] Fujitsu fi-4010CU

2006-05-20 Thread Giuseppe Sacco
Il giorno sab, 20/05/2006 alle 22.15 +0200, Ren? Rebe ha scritto: [...] Yep that should be avision based. I'm a bit out of sync right now, are the usb snoops available? http://lists.alioth.debian.org/pipermail/sane-devel/2006-May/016844.html If you need anything more just ask. But I have the

[sane-devel] Nikon CoolScan IV and next sane release

2006-05-27 Thread Giuseppe Sacco
Henning Meier-Geinitz ha scritto: [...] you (or somebody else) post a patch that includes my and your comments? I.e. that can't break support for the other scanners? And that is tested with the LS-50? Hi Henning, please find the new patch, where I correct one small error and tested it with

[sane-devel] Fujitsu backend update (saned,M3091/92,testers)

2006-06-19 Thread Giuseppe Sacco
Hi *, today I had a new fujitsu fi-5110C to test sane on. I used today CVS sane backends on a powerpc machine. The backend passed all my (simple) tests. The only strange behaviour I noticed is that scanimage complain about a rounded value that is not rounded at all: giuseppe@eppesuig3:~/sane$

[sane-devel] sane.ps

2006-09-07 Thread Giuseppe Sacco
Il giorno mer, 06/09/2006 alle 22.18 +0100, Jon Chambers ha scritto: Hi, At the end of my (latest CVS) sane-backends build I get a failure when trying to make sane.ps. Running latex manually on sane.tex reveals that I don't seem to have either times.sty or changebar.sty available. Are

[sane-devel] EXIF data in TIFF images

2006-09-09 Thread Giuseppe Sacco
Hi all, is there any way, using SANE API, to pass EXIF data from a backend to the application? I am looking at the coolscan2 backend and wondering if resolution, position, date, scanner model, etc could be stored in the output TIFF file. Thanks, Giuseppe

[sane-devel] EXIF data in TIFF images

2006-09-09 Thread Giuseppe Sacco
Hi all, is there any way, using SANE API, to pass EXIF data from a backend to the application? I am looking at the coolscan2 backend and wondering if resolution, position, date, scanner model, etc could be stored in the output TIFF file. I found an old thread about this subject, of august

[sane-devel] EXIF data in TIFF images

2006-09-09 Thread Giuseppe Sacco
m. allan noah wrote: [...] what parts of exif cannot be extracted from existing sane options? allan Probably the best answer is to look at all possibile tags that a scanner could set: http://www.exiv2.org/tags.html The list is from the exiv2 project, a free software that display and modify

[sane-devel] infrared, SANE_FRAME_RGBA

2006-12-14 Thread Giuseppe Sacco
Hi Gerard and all SANE developers, Il giorno gio, 14/12/2006 alle 13.40 +0100, Gerhard Jaeger ha scritto: [...] But I think you are right, we are moving into a dead-end. We have devices that are able to do much more than we are able to support with the SANE 1 standard AND we have a not yet

[sane-devel] coolscan V

2006-12-19 Thread Giuseppe Sacco
Hi Francesco, Il giorno sab, 16/12/2006 alle 14.50 -0800, Francesco Pietra ha scritto: [..-] QUESTION: In order to check if my coolscan is operated (minimum) by sane-coolscan2.5, can this library be added to my system as it is, or should sane replace xsane. Also, is a deb package somewhere

[sane-devel] SANE2 commitment

2006-12-19 Thread Giuseppe Sacco
Hi Martin, Il giorno dom, 17/12/2006 alle 19.52 +, Martin Owens ha scritto: [...] For device detection and management use HAL, update hal dbus code with all existing detection and status code which will keep these devices happy, enable the modification of the hal xml as a simple way of

[sane-devel] Frontend for film scanners

2007-01-15 Thread Giuseppe Sacco
Hi Ren?, Il giorno dom, 14/01/2007 alle 12.18 +0100, Rene Rebe ha scritto: [...] I was thinking about about creating a shiny SANE frontend for professional digital imaging workflow for Linux for some time already. If you really plan to write such a program, I would like to offer my help in

[sane-devel] Strings clarification

2007-02-24 Thread Giuseppe Sacco
I have a problem understanding the meaning of a few messages. Could anyone please help clarifying it? # canon.c:476 power on reset / bus device reset # canon.c:506 initiator detected error message received # canon.c:519 trancparency unit shading error # canon.c:462 option not connect Thanks,

[sane-devel] Negative slide?

2007-02-24 Thread Giuseppe Sacco
While updating the Italian translation for sane, I found this new string for the epson2 backend: Negative Slide. While I could probably translate it without problem, I wonder what a negative slide is. What is the difference between a normal film and a negative slide? Bye, Giuseppe

[sane-devel] [patch] --quality scan option for coolscan2 backend

2007-02-25 Thread Giuseppe Sacco
: text/x-patch Size: 5904 bytes Desc: not available Url : http://lists.alioth.debian.org/pipermail/sane-devel/attachments/20070225/da4391c7/sane-coolscan2-quality.bin From giuse...@eppesuigoccas.homedns.org Sun Feb 25 12:32:20 2007 From: giuse...@eppesuigoccas.homedns.org (Giuseppe Sacco) Date: Sun

[sane-devel] More comments on coolscan2 and LS-50 ED

2007-03-04 Thread Giuseppe Sacco
Hi, I made a few more tests and I read the coolscan2 source code. I used scanimage, xsane and gimp/xscanimage as frontends. I think that the --negative option already included, but disabled, somewhat works. It is not perfect since preview (in xscanimage) seems to be unaffected by this option, so

[sane-devel] Frustrated with making saned work

2007-04-22 Thread Giuseppe Sacco
Hi Mac, Il giorno sab, 21/04/2007 alle 18.05 -0500, Mac Cody ha scritto: [...] *** glibc detected *** free(): invalid pointer: 0x4001a7e6 *** I tried setting up a psc_umax2100u.users file, following the same format as saned.users, but that didn't work. Probably not a valid file anyway.

[sane-devel] frame and batch mode

2007-12-18 Thread Giuseppe Sacco
Hi all, I am slowly working on the coolscan2 backend and I am looking at tiffscan for batch scanning. What I see is that any frontend that would drive a batch scan should manage different type of feeder and pages. Probably the easier one is the ADF case where the scanner load/eject every page;

[sane-devel] frame and batch mode

2007-12-18 Thread Giuseppe Sacco
Il giorno mar, 18/12/2007 alle 12.00 +, Jonathan Buzzard ha scritto: On Tue, 2007-12-18 at 12:13 +0100, Giuseppe Sacco wrote: [...] So, my questions: is there already any standard for those action? Is there any defined rule for how to name a backend parameter like --frame-number

[sane-devel] frame and batch mode

2007-12-18 Thread Giuseppe Sacco
Il giorno mar, 18/12/2007 alle 08.40 -0500, m. allan noah ha scritto: On 12/18/07, Giuseppe Sacco giuseppe at eppesuigoccas.homedns.org wrote: [...] why does the front-end need to be involved in the movement at all? can the backend not detect the additional slides and move the feeder

[sane-devel] frame and batch mode

2007-12-18 Thread Giuseppe Sacco
Il giorno mar, 18/12/2007 alle 09.37 -0500, m. allan noah ha scritto: [...] ahh- so how does the user determine this offset? does he measure the strip before placing it in the machine? We do not behave all the same way, so I will tell you how I am used to work. I preview the first frame, then

[sane-devel] USB device locking in the snapscan backend

2008-03-01 Thread Giuseppe Sacco
On Sun, 24 Feb 2008 17:12:17 +0100 Julien BLACHE jb at jblache.org wrote: Hi, The snapscan backend uses a mutex to lock the USB device it's working with when sending atomic commands. We're not talking about pthread mutexes here, which is one of the available implementations, but IPC

[sane-devel] root gets correct 'scanimage -L' results, but user does not, even if I hack permissions

2008-03-24 Thread Giuseppe Sacco
On Mon, 24 Mar 2008 08:29:09 -0700 Rusty Carruth rustyc at descomp.com wrote: I asked this a while back and heard zilch, so I'll try again. Please do not be put off by my email address! I'm a real person, asking a real question! [...] If I chmod the scanner device in /proc/bus/usb to 666 I

[sane-devel] epson 1660 photo

2003-11-26 Thread Giuseppe Sacco
Hi, I am interested in a scanner for A4 papers and films and slides. I did buy an HP ScanJet 3670 but sadly it is not supported by sane. This scanner was broken so I will get it back to the store and I think I may ask for a different replacement. I saw in the sane 'supported devices' list the

[sane-devel] problem scanning slides with an EPSON 1670 Photo

2003-11-27 Thread Giuseppe Sacco
I ginally bought this new scanner and I am making some tests. It seems that is well supported by sane but I found some problems: 1. all b/w pictures are too dark 2. the slide and film scan shown a pretty incorrect output (check http://eppesuigoccas.homedns.org/~giuseppe/scanner1670/ ) for two

[sane-devel] scanner suggestion

2003-12-17 Thread Giuseppe Sacco
I would like to buy a scanner for a company that will archive his internal documentation, moving from paper to CDROM. I found, trying many scanners, that very often the quality is not good when acquiring documents from very thin sheets or from sheets that have a black rear side (for carbon copy

[sane-devel] support for Nikon CoolScan V LS-50

2004-09-25 Thread Giuseppe Sacco
Hi all, I read that backend coolscan2 could be modified in order to support the LS-50. I have such a scenner and I am interested in developing/supporting this driver. If anyone already developed some code and would like me to test it, then I may give it a try. Let me know, Giuseppe

[sane-devel] sane and mingw/msys

2004-05-01 Thread Giuseppe Sacco
[please CC to me since I not subscribed ATM] Hi, I am still trying to have sane working with my usb scanner (epson perfection 1670 photo) under Windows but still without luck. I did tried in april using cygwin and maybe you read my posts. I did managed to compile sane but it wasn't working with

[sane-devel] problems compiling on cygwin and a java question

2004-08-19 Thread Giuseppe Sacco
Hi sane developers, we are experiencing some strange problems compiling the latest CVS snapshot on an up-to-date cygwin installation. 1. if we just use the vanilla 'configure' without specifing any arguments then we get an error when compiling backend/coolscan.c, at line 2593. The error is:

[sane-devel] problems compiling on cygwin and a java question

2004-08-22 Thread Giuseppe Sacco
Henning Meier-Geinitz wrote: Hi, [...] 1. if we just use the vanilla 'configure' without specifing any arguments then we get an error when compiling backend/coolscan.c, at line 2593. The error is: sa_handler field doesn't exists. Strange. sa_handler is also used by other backends. Maybe we

[sane-devel] Is USB 2 for Epson scanners really only for factory installed Windows 2000/XP?

2004-08-26 Thread Giuseppe Sacco
Il gio, 2004-08-26 alle 14:26, Steven P. Ulrick ha scritto: Hello, Everyone :) I just purchased an Epson Perfection 2400 PHOTO Scanner, and it hasn't arrived yet, hence this question. I was just perusing the Epson I use the epson Perfection 1670 Photo with usb2.0 without any problem. Bye,

[sane-devel] problem in compiling on cygwin

2004-04-02 Thread Giuseppe Sacco
Hi, I am trying to check if saned works on windows, so I installed cygwin and downloaded the latest release of sane-backedns. I got an error that happens even using backends from CVS: ... checking for CC... CC checking whether we are using the GNU C++ compiler... no checking whether CC accepts

[sane-devel] problem in compiling on cygwin

2004-04-02 Thread Giuseppe Sacco
Il ven, 2004-04-02 alle 18:58, Henning Meier-Geinitz ha scritto: Hi, [...] I haven't heard about that problem until now. Can you show us the complete output of configure and also config.log? Doesn't use cygwin gcc? I'd expect checking for gcc... gcc in this case. And it looks strange to

[sane-devel] problem in compiling on cygwin

2004-04-03 Thread Giuseppe Sacco
--=-EbXa38G+v02y7dk+Bb2c Content-Type: text/plain Content-Transfer-Encoding: 7bit Il ven, 2004-04-02 alle 19:52, Henning Meier-Geinitz ha scritto: [...] When the project doesn't use C++, treating the failed C++ /lib/cpp as a fatal error is atrocious. At least on Linux, there is no fatal

[sane-devel] problem in compiling on cygwin

2004-04-05 Thread Giuseppe Sacco
Il lun, 2004-04-05 alle 19:11, Henning Meier-Geinitz ha scritto: Hi, [...] That's from libtool. Looks like it checks for C++ compilers and thinks CC is one of those. What is CC in reality? I have been told that CC *is* a c++ compiler. So if anything is called CC on your system which can't

[sane-devel] Re: SANE LS50ED

2005-01-05 Thread Giuseppe Sacco
Il giorno mer, 05-01-2005 alle 12:12 +, Major A ha scritto: Any suggestions for further tests/debugging info is welcome. What we need is someone to spare a few hours and check the USB log of VueScan or Nikonscan against the Coolscan2 code. There's something the scanner doesn't like

[sane-devel] problems compiling on cygwin and a java question

2005-01-11 Thread Giuseppe Sacco
Il giorno ven, 20-08-2004 alle 19:13 +0200, Henning Meier-Geinitz ha scritto: [...] 2. if you use a different compiler, i.e., 'gcc-2' instead of 'gcc', the compilation process stops on backend/gt68xx.c, line 242, since SHM_R is not definded. How may we tell 'configure' to do not compile a

[sane-devel] is coolscan2 maintained?

2004-10-03 Thread Giuseppe Sacco
Il Sun, Oct 03, 2004 at 12:46:44PM +0200, Ulrich Eckhardt ha scritto: [...] the last time i heard about him was in July. I had send him some logs from my Coolscan 5 and he replied, that he is now working on a backend. Ok, thanks. I will wait some more then. Bye, Giusepe

[sane-devel] is coolscan2 maintained?

2004-10-07 Thread Giuseppe Sacco
Il gio, 2004-10-07 alle 00:41, Major A ha scritto: [...] I tried to get the first point done a few times, but it has proved a bit difficult with no direct access to a scanner. If anyone could work out what needs to be done, I'd be happy to incorporate it into the code. Same goes for all other

[sane-devel] Translation

2004-10-13 Thread Giuseppe Sacco
Il mar, 2004-10-12 alle 23:32, Mogens Jaeger ha scritto: Hello I have been working on the Danish translation of Sane-backends-1.0.15 - from cvs. I don't understand the meaning of: Red-gain value of the AFE This AFE - is it a professional term that's not needed to translate, or

[sane-devel] some english words

2004-10-23 Thread Giuseppe Sacco
Hi all, I am updating the italian translation for sane-backends and I have a questiong about radiance and brightness: are these synonims in english? If they are then I will translate both with luminosit=E0, otherwise I have to understand what is the difference between them. The radiance word is

[sane-devel] Scanner Question

2005-06-08 Thread Giuseppe Sacco
Il giorno mar, 07-06-2005 alle 18:59 +0200, Spiro Angeli ha scritto: Hi, =20 I need an advice - if possible, please. =20 I have to scann 15000 35mm frames and 350 slides. I wish to purchase a NIKON scanner which will be connected via USB and wi= ll=20 work on Linux hopefully =20 Here couple

[sane-devel] Bug in snapscan or sane network protocolo?

2005-06-09 Thread Giuseppe Sacco
Hi all, I am using an EPSON Perfection 1670 over the network, via saned, and I just found a problem. Basically I do a scan of 210.0x297.0mm, using a 200dpi resolution. Prior to scan I call get_parameters and receive an *estimated* values for lines, pixelsperline, bytesperline; after receiving

[sane-devel] Bug in snapscan or sane network protocolo?

2005-06-10 Thread Giuseppe Sacco
Il giorno gio, 09-06-2005 alle 19:50 +0200, Henning Meier-Geinitz ha scritto: Hi, On Thu, Jun 09, 2005 at 04:47:05PM +0200, Giuseppe Sacco wrote: Basically I do a scan of 210.0x297.0mm, using a 200dpi resolution. Prior to scan I call get_parameters and receive an *estimated* values

[sane-devel] Bug in snapscan or sane network protocolo?

2005-06-10 Thread Giuseppe Sacco
Il giorno gio, 09-06-2005 alle 19:50 +0200, Henning Meier-Geinitz ha scritto: [...] while, when scanning, I get a different amount of data: This is perfectly legal (see SANE standard). The normal way is: sane_get_parameters (returns estimated values) sane_start sane_get_parameters

[sane-devel] Scanning Time Question]]

2005-06-10 Thread Giuseppe Sacco
Il giorno gio, 09-06-2005 alle 21:33 +0200, Spiro Angeli ha scritto: Hi johannes, [...] I thought you were going to use SANE. Then you don't need vuescan. So basically, SANE is the back end. Correct? Then as front end what will I use? I believe I was referring to VueScan as front-end. Please

[sane-devel] Saned

2005-06-14 Thread Giuseppe Sacco
Il giorno dom, 12-06-2005 alle 12:26 +0100, Andi McLean ha scritto: Hi, I'm the maintainer of the JSane-net project. I have an issue with the Sane netowork protocol. To find the size / resolution and pixel depth of an image, I need to call sane_get_parameters() If I do this before

[sane-devel] Coolscan V ED available [was: Re: Nikon Coolscan V ED / LS 50 ED]

2005-08-05 Thread Giuseppe Sacco
Il giorno mar, 17/05/2005 alle 13.48 +0200, Ariel Garcia ha scritto: Hi, [...] I had hoped to be able to make it work but i am still waiting for Nikon to decide if they are going to provide me the specs under NDA. The fact that i don't have(don't want to use) a company affiliation seems to

[sane-devel] Scanning for VistA

2005-08-16 Thread Giuseppe Sacco
Hi Nancy, I think your question already appeared on this list so you might have a look at the list archives. Il giorno sab, 13/08/2005 alle 09.44 -0400, Nancy Anthracite ha scritto: [...] All this leads up to my question. We have some volunteers working on developing the software to do that

[sane-devel] scanimage via network

2005-09-06 Thread Giuseppe Sacco
Hi, what is the syntax for scanning images using scanimage on a scanner connected to a remote machine. I have a machine with saned configured and would like to use scanimage from a different machine. I cannot understand what I sould specify as --device-name argument. Thank you, Giuseppe

[sane-devel] scanimage via network

2005-09-06 Thread Giuseppe Sacco
I just found the answer :-) scanimage -d net:IPADDRESS:BACKENDNAME:LOCALDEVICESPEC

[sane-devel] Nikon LS50

2005-11-01 Thread Giuseppe Sacco
Il giorno gio, 27/10/2005 alle 17.58 +0200, Ariel Garcia ha scritto: Hi, here is the patch for adding support for the Nikon LS50/LS5000. It applies on top of the backends/coolscan2.c file of sane-1.0.16 Hi Ariel, thank you very much for workign at this scanner. I am testing your patch and

[sane-devel] [ANNOUNCE] Code freeze for sane-backends 1.0.17

2005-12-12 Thread Giuseppe Sacco
Il giorno dom, 11/12/2005 alle 19.03 +0100, Henning Meier-Geinitz ha scritto: Hi everyone, Code freeze for sane-backends 1.0.17 is now active. After code freeze only fixes of grave bugs that render a backend completely unusable or break compilation and documentation updates are accepted.