Hi Alessandro and Olaf,
thanks for the patch.
Am Freitag, 8. Januar 2010 schrieb Alessandro Zummo:
On Fri, 8 Jan 2010 00:25:54 +0100
Rainer Dorsch rdorsch at web.de wrote:
will can do more tests on the weekend. Is there something you would
consider of high value? Varying resolutions
Hi Alessandro,
Am Mittwoch, 6. Januar 2010 schrieb Alessandro Zummo:
On Wed, 6 Jan 2010 22:30:23 +0100
Rainer Dorsch rdorsch at web.de wrote:
Did you forget to add a new patch or do you think the old one compensates
already for the 8 lines?
The backend does some compensation, but a few
Alessandro,
Am Sonntag, 3. Januar 2010 schrieb Alessandro Zummo:
On Sun, 3 Jan 2010 19:09:56 +0100
Rainer Dorsch rdorsch at web.de wrote:
Can you point me to the locations in the code?
I believe the bug lies in line 1260 of epson2-ops.c .
The code block should probably happen later
wrong is welcome :-)
Thanks,
Rainer
--
Rainer Dorsch
L?rchenstr. 6
D-72135 Dettenhausen
07157-734133
email: rdorsch at web.de
jabber: rdorsch at jabber.org
GPG Fingerprint: 5966 C54C 2B3C 42CC 1F4F 8F59 E3A8 C538 7519 141E
Full GPG key: http://pgp.mit.edu/
-- next part
Alessandro,
many thanks for your quick reply.
Am Mittwoch, 6. Januar 2010 schrieben Sie:
On Wed, 6 Jan 2010 18:44:18 +0100
Rainer Dorsch rdorsch at web.de wrote:
I'm attaching a patch, please test with
epson2 debug level 11
I did a
git reset HEAD --hard
to get rid of my local
Am Mittwoch, 6. Januar 2010 schrieben Sie:
On Wed, 6 Jan 2010 21:51:08 +0100
Rainer Dorsch rdorsch at web.de wrote:
Seems now we are scanning 8 lines less than the requested 1754:
[epson2] written 1746 lines after color shuffle
[epson2] lines requested: 1746
Should we compensate
: */
s-opt[OPT_CCT_GROUP].title = SANE_I18N(Color correction);
s-opt[OPT_CCT_GROUP].desc = ;
s-opt[OPT_CCT_GROUP].type = SANE_TYPE_GROUP;
- s-opt[OPT_CCT_GROUP].cap |= SANE_CAP_ADVANCED;
+ s-opt[OPT_CCT_GROUP].cap = SANE_CAP_ADVANCED;
--
Rainer Dorsch
L
Alessandro,
Am Montag, 4. Januar 2010 schrieben Sie:
On Mon, 4 Jan 2010 13:43:27 +0100
Rainer Dorsch rdorsch at web.de wrote:
/home/rd/SW.nobackup/sane-backends/frontend/.libs/lt-scanimage:
unrecognized option `--help'
rd at blackbox:~/SW.nobackup/sane-backends$
that's strange
Chris,
that was an excellent observation again. When installing everything it works
as expected :-)
Now I start testing the fix proposal for the bug which generates corrupted
pnms...
Thanks again,
Rainer
Am Montag, 4. Januar 2010 schrieben Sie:
On Mon, Jan 4, 2010 at 1:45 PM, Rainer Dorsch
, Jan 2, 2010 at 5:45 PM, Rainer Dorsch rdorsch at web.de wrote:
Allan,
(cc'ed Karl Heinz since he is listed as epson backend author)
I used latest git code now.
rd at dell:~$ scanimage --version
scanimage (sane-backends) 1.0.21cvs; backend version 1.0.21
rd at dell:~$
The first
Hi Alessandro,
thank you for the quick reply.
Am Sonntag, 3. Januar 2010 schrieb Alessandro Zummo:
On Sun, 3 Jan 2010 14:01:15 +0100
Rainer Dorsch rdorsch at web.de wrote:
I was not aware that there is an epson2 backend, thanks for pointing that
out. You are right, twelve pixels rows
?
Thanks,
Rainer
Am Sonntag, 3. Januar 2010 schrieb Alessandro Zummo:
On Sun, 3 Jan 2010 15:14:38 +0100
Rainer Dorsch rdorsch at web.de wrote:
Are these the areas in epson2.c you are refering to:
/*
* Make sure that the number of lines is correct for color
shuffling
Hi Chris,
Am Sonntag, 3. Januar 2010 schrieb Chris Bagwell:
On Sun, Jan 3, 2010 at 7:01 AM, Rainer Dorsch rdorsch at web.de wrote:
For the long options issue:
I rebuild git sane on another machine (also Debian stable aka Debian 5.0)
and
the long options error is still there. Even --help
snapshot?
allan
On Tue, Dec 29, 2009 at 5:34 AM, Rainer Dorsch rdorsch at web.de wrote:
Hello,
when scanning with the Epson Perfection 610 with 150dpi color mode, sane
creates corrupted files
rd at dell:~$ scanimage -L
device `epson2:libusb:001:003' is a Epson Perfection610 flatbed
,
Rainer
PS: I changed the subject to Epson Perfection 610 (510 was a typo)
Am Mittwoch, 30. Dezember 2009 schrieben Sie:
Could you try a more recent version of sane-backends, or perhaps a git
snapshot?
allan
On Tue, Dec 29, 2009 at 5:34 AM, Rainer Dorsch rdorsch at web.de wrote:
Hello
Hello,
when scanning with the Epson Perfection 610 with 150dpi color mode, sane
creates corrupted files
rd at dell:~$ scanimage -L
device `epson2:libusb:001:003' is a Epson Perfection610 flatbed scanner
device `epson:libusb:001:003' is a Epson Perfection610 flatbed scanner
device
Am Samstag, 26. April 2008 schrieb Julien BLACHE:
Rainer Dorsch rdorsch at web.de wrote:
Hi,
The script works now reasonably robust (for now) when I plug the USB
scanner. My problem is though, that the script does not get called when I
boot the system and the scanner is plugged already
,
GROUP=scanner, NAME=umax%n, RUN+=/usr/local/bin/umax1220u start,
ENV{lamp_off}=yes
blackbox:~#
/etc/init.d/udev restart does not call the script either.
Any ideas what I am missing are welcome...
Thanks,
Rainer
--
Rainer Dorsch
L?rchenstr. 6
D-72135 Dettenhausen
07157-734133
email: rdorsch
Johannes,
Am Donnerstag, 24. April 2008 schrieb Johannes Meixner:
Hello,
On Apr 23 22:53 Rainer Dorsch wrote:
Am Mittwoch, 23. April 2008 schrieb Julien BLACHE:
Johannes Meixner jsmeix at suse.de wrote:
Hi,
umax1220u scripts are started in a sequence (i.e. not in parallel
for this problem?
Thanks,
Rainer
--
Rainer Dorsch
L?rchenstr. 6
D-72135 Dettenhausen
07157-734133
email: rdorsch at web.de
jabber: rdorsch at jabber.org
GPG Fingerprint: 5966 C54C 2B3C 42CC 1F4F 8F59 E3A8 C538 7519 141E
Full GPG key: http://pgp.mit.edu/
the
scanner lamp off?
Thanks,
Rainer
--
Rainer Dorsch
L?rchenstr. 6
D-72135 Dettenhausen
07157-734133
email: rdorsch at web.de
jabber: rdorsch at jabber.org
GPG Fingerprint: 5966 C54C 2B3C 42CC 1F4F 8F59 E3A8 C538 7519 141E
Full GPG key: http://pgp.mit.edu/
21 matches
Mail list logo