** Bug watch added: github.com/lxqt/lxqt-config/issues #756
https://github.com/lxqt/lxqt-config/issues/756
** Also affects: lxqt via
https://github.com/lxqt/lxqt-config/issues/756
Importance: Unknown
Status: Unknown
--
You received this bug notification because you are a member
Lubuntu 20.04.3 QA-test install to
- dell [optiplex] 755 (c2d-e8300, 8gb, amd/ati radeon rv610/radeon hd2400
pro/xt)
testcase: full disk, encryption, BIOS, internet
in setup of box (monitor is portrait-left); a gap opened between
monitors... updated to include focal.
** Tags added: focal
--
** Description changed:
This is a Lubuntu groovy (20.10) QA-test install first boot on
- dell [optiplex] 755 (c2d-e8300, 8gb, amd/ati radeon rv610/radeon hd2400
pro/xt)
+ - dell [optiplex] 755 (c2d-e8300, 8gb, amd/ati radeon rv610/radeon hd2400
pro/xt)
As part of post-install checks, I
package change ^ was suggested by Dan/kc2bez
I just confirmed the issue still occurs on opensuse tumbleweed.
Tumbleweed wasn't fully updated (packages updating now), however
VERSION = 2021.06.20
lxqt 0.17.0
liblxqt 0.17.0
Qt 5.15.2
I see some Qt5 libs being updated... some are LXQt it turns
** Package changed: lxqt-session (Ubuntu) => lxqt-config (Ubuntu)
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1882411
Title:
lubuntu monitor settings touching screens with gap between
To manage
Lubuntu impish daily QA-test (live) on
- dell [optiplex] 755 (c2d-e8300, 8gb, amd/ati radeon rv610/radeon hd2400
pro/xt)
adjusted monitors to match setup (landscape+portrait) & a gap appears
between them on moving windows around - YET none show in
monitor.settings...
Note: The
Same session as prior comment... (firefox & prior comment can be seen on
firefox)
Key in this picture is the Monitor.Settings window was moved between
displays. The middle of the window cannot be viewed.
** Attachment added: "screen_1882411-2.jpg"
Lubuntu impish daily QA-test (live) on
- dell [optiplex] 755 (c2d-e8300, 8gb, amd/ati radeon rv610/radeon hd2400
pro/xt)
adjusted monitors to match setup (landscape+portrait) & a gap appears
between them on moving windows around - YET none show in
monitor.settings... ie.
Lubuntu hirsute live QA-test on
- dell [optiplex] 755 (c2d-e8300, 8gb, amd/ati radeon rv610/radeon hd2400
pro/xt)
box originally filed with. During my actual QA-test I didn't notice any
issues, and I left the box sitting idle still running..
a (ask ubu) support question (related to 1366x768
Continuing from last comment (#8) I've decided to skip the remaining
pictures I took.
1. it's difficult to re-create (on installed systems, thus to be found by
upstream devs)
2. it's easily worked around
3. the gap in this (comment #8 & #9) case isn't "hidden" as I describe it in
the initial
I've been successful in re-creating this now in Debian Bullseye/sid on
- dell [optiplex] 780 (c2q-q9400, 8gb, amd/ati cedar radeon hd
5000/6000/7350/8350)
(research aimed at filing upstream; versions of LXQt is identical to
hirsute I believe)
HOWEVER it took a lot of play before I could get
This bug has been reported on the Ubuntu ISO testing tracker.
A list of all reports related to this bug can be found here:
http://iso.qa.ubuntu.com/qatracker/reports/bugs/1882411
** Tags added: iso-testing
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is
the QA-test install (install alongside mentioned in comments #4 & #5)
was logged in and also has the same issue. Same box, but subsequent
install.
Picture is reason for comment (this is the other install to #4-5 but
effect is identical). pcmanfm-qt is on left monitor, monitor.settings
is on
Using the QA-test install mentioned in comment #4 (2021-03-20 daily
ISO)
I `apt install fluxbox xfwm4` and switched out openbox to
- fluxbox
- xfwm4
after changing the WM, I'd
- logout
- login
- open monitor.settings
- change screen to a different position, apply & save
- change screen to
I just noticed this bug on a QA-test install on same d755-8
refer
http://iso.qa.ubuntu.com/qatracker/milestones/419/builds/228371/testcases/1701/results/
during second install (install alongside), whilst logging into the
original install I noted a huge gap as I moved the cursor between
2021-feb-23 QA-test installs
I've experienced this on a QA-test install on d755-8 (same box bug is
filed against). I was attempting to explore other 'older' bugs on new
LXQt 0.16
Report details can be seen at https://bugs.launchpad.net/ubuntu/+source
/lxqt-panel/+bug/1810075/comments/14
Lubuntu groovy install & strange behavior with Monitor.Settings
I have Keep.Monitors.Attached clicked.
I experienced strange behavior again today with Lubuntu in *live*
session, then tested later on opensuse tumbleweed using LXQt 15.1 ...
same if not similar behavior.. (too tired for more
17 matches
Mail list logo