Re: RUTA problem with extended DKPro Type System

2020-07-17 Thread Björn Rudzewitz
Dear Peter, thank you very much for your helpful answer! I tried the two options and both lenient loading and a merged type system in the project root worked for me. Thanks a lot! Best regards, Björn Rudzewitz Am 15.07.20 um 12:42 schrieb Peter Klügl: Hi, the problem is that the type

Re: RUTA problem with extended DKPro Type System

2020-07-15 Thread Peter Klügl
Hi, the problem is that the type system used to open the XMI file does not define all typed present in the XMI. Short answer: If you do not really care about the type DocumentMetaData, then activate leniently loading in the preferences: Menu -> Window -> Preferences -> UIMA Cas Editor ->

RUTA problem with extended DKPro Type System

2020-07-14 Thread Björn Rudzewitz
Dear all, I want use RUTA to develop rules to extend the output of a UIMA pipeline. The original pipeline is defined in another project and uses a type system that extends the DKPro type system by importing certain types from it, but it also has custom types that are not available in DKPro.