Hi all, The release process for Pacemaker 1.1.17 will start soon! The most significant new feature is container bundles, developed by Andrew Beekhof. Pacemaker's container story has previously been muddled. For the simplest case, the ocf:heartbeat:docker agent allows you to launch a docker

Re: [ClusterLabs] Syncing data and reducing CPU utilization of cib process

2017-03-31 Thread Ken Gaillot
On 03/31/2017 06:44 AM, Nikhil Utane wrote: > We are seeing this log in pacemaker.log continuously. > > Mar 31 17:13:01 [6372] 0005B932ED72cib: info: > crm_compress_string: Compressed 436756 bytes into 14635 (ratio 29:1) in > 284ms > > This looks to be the reason for high CPU. What

Re: [ClusterLabs] Three node cluster becomes completely fenced if one node leaves

2017-03-31 Thread Seth Reid
We are only using one mount, and that mount has nothing on it currently. I have fixed the problem. Our OS is Ubuntu 16.04 LTS (Xenial). I added the 17.04 (Zesty) repo to get newer a newer version of Corosync. I upgraded Corosync, which upgraded a long list of other related packages (Pacemaker

Re: [ClusterLabs] Three node cluster becomes completely fenced if one node leaves

2017-03-31 Thread Bob Peterson
- Original Message - | I can confirm that doing an ifdown is not the source of my corosync issues. | My cluster is in another state, so I can't pull a cable, but I can down a | port on a switch. That had the exact same affects as doing an ifdown. Two | machines got fenced when it should

Re: [ClusterLabs] Three node cluster becomes completely fenced if one node leaves

2017-03-31 Thread Seth Reid
I can confirm that doing an ifdown is not the source of my corosync issues. My cluster is in another state, so I can't pull a cable, but I can down a port on a switch. That had the exact same affects as doing an ifdown. Two machines got fenced when it should have only been one. --- Seth Reid

Re: [ClusterLabs] Syncing data and reducing CPU utilization of cib process

2017-03-31 Thread Nikhil Utane
We are seeing this log in pacemaker.log continuously. Mar 31 17:13:01 [6372] 0005B932ED72cib: info: crm_compress_string: Compressed 436756 bytes into 14635 (ratio 29:1) in 284ms This looks to be the reason for high CPU. What does this log indicate? -Regards Nikhil On Fri, Mar 31,

Re: [ClusterLabs] Antw: Re: question about ocf metadata actions

2017-03-31 Thread Dejan Muhamedagic
On Fri, Mar 31, 2017 at 09:46:18AM +0200, Kristoffer Grönlund wrote: > Ulrich Windl writes: > > > I thought the hierarchy is like this: > > 1) default timeout > > 2) RA's default timeout > > 3) user-specified timeout > > > > So crm would go from 1) to 3) taking

Re: [ClusterLabs] Three node cluster becomes completely fenced if one node leaves

2017-03-31 Thread Dejan Muhamedagic
Hi, On Fri, Mar 31, 2017 at 02:39:02AM -0400, Digimer wrote: > On 31/03/17 02:32 AM, Jan Friesse wrote: > >> The original message has the logs from nodes 1 and 3. Node 2, the one > >> that > >> got fenced in this test, doesn't really show much. Here are the logs from > >> it: > >> > >> Mar 24

Re: [ClusterLabs] Stonith

2017-03-31 Thread Alexander Markov
Kristoffer Grönlund writes: The only solution I know which allows for a configuration like this is using separate clusters in each data center, and using booth for transferring ticket ownership between them. Booth requires a data center-level quorum (meaning at least 3 locations), though the

Re: [ClusterLabs] Antw: Re: question about ocf metadata actions

2017-03-31 Thread Kristoffer Grönlund
Ulrich Windl writes: > I thought the hierarchy is like this: > 1) default timeout > 2) RA's default timeout > 3) user-specified timeout > > So crm would go from 1) to 3) taking the last value it finds. Isn't it like > that? No, step 2) is not taken by crm. >

[ClusterLabs] Antw: Re: question about ocf metadata actions

2017-03-31 Thread Ulrich Windl
>>> Kristoffer Grönlund schrieb am 30.03.2017 um 13:43 in Nachricht <87o9wjm1lw@suse.com>: > he.hailo...@zte.com.cn writes: > >> Hi, >> >> >> Does the timeout configured in the ocf metadata actually take effect? >> >> >> >> >> <actions> >> >> <action name="start"

Re: [ClusterLabs] Three node cluster becomes completely fenced if one node leaves

2017-03-31 Thread Digimer
On 31/03/17 02:32 AM, Jan Friesse wrote: >> The original message has the logs from nodes 1 and 3. Node 2, the one >> that >> got fenced in this test, doesn't really show much. Here are the logs from >> it: >> >> Mar 24 16:35:10 b014 ntpd[2318]: Deleting interface #5 enp6s0f0, >>

[ClusterLabs] Syncing data and reducing CPU utilization of cib process

2017-03-31 Thread Nikhil Utane
Hi, In our current design (which we plan to improve upon) we are using the CIB file to synchronize information across active and standby nodes. Basically we want the standby node to take the configuration that was used by the active node so we are adding those as resource attributes. This ensures

Re: [ClusterLabs] Three node cluster becomes completely fenced if one node leaves

2017-03-31 Thread Jan Friesse
The original message has the logs from nodes 1 and 3. Node 2, the one that got fenced in this test, doesn't really show much. Here are the logs from it: Mar 24 16:35:10 b014 ntpd[2318]: Deleting interface #5 enp6s0f0, 192.168.100.14#123, interface stats: received=0, sent=0, dropped=0,