The problem here is when we are sending back the message with session ID
from the mBlox which is AptyrB+v+LkAABkA+ncgAUaIPk807E800QQ$... the
SMSC return the error code... 0x0435 (Vendor-specific error, please
refer to your SMPP provider).. Using the Portal we have from MBlox we
came to
-Original Message-
From: users-boun...@kannel.org [mailto:users-boun...@kannel.org] On
Behalf Of Ishtiaq Ahmed
Sent: Friday, March 27, 2009 4:23 PM
To: Nikos Balkanas
Cc: users@kannel.org; Andrey Ponteleev; Alejandro Guerrieri
Subject: Re: problem with get-url or encoding
Thanks Nikos,
Well, what's the URL you are trying to invoke?
On Mon, Mar 30, 2009 at 8:58 AM, narendra reddy
kamaninaren...@gmail.com wrote:
Hi users,
when i am trying to hit the url i am getting below error in the smsbox logs
.can anybody tell me wat is the reason for below error.
2009-03-30 17:24:13
ttp://localhost:13001/cgi-bin/sendsms?username=pyropassword=pyrofrom=to=91971236987text=Test%20Messagecharset=UTF-16BEmclass=2coding=1pid=0dlr-mask=1dlr-url=
http://localhost/dlr.mysql.php?smscID=SMPPSim
i am invoking this url.
On Mon, Mar 30, 2009 at 6:42 PM, Rodrigo Cremaschi
In ttp:// You're missing the h.
Besides that, you must URL-encode the dlr-url parameter, like this:
$dlr-url=http%3A%2F%2Flocalhost%2Fdlr%2Emysql%2Ephp%3FsmscID%3DSMPPSim
On Mon, Mar 30, 2009 at 10:51 AM, narendra reddy
kamaninaren...@gmail.com wrote:
Hello Guys,
I'm looking for GSM modems to host sim cards. Can somebody refer some
websites or dealers to get that in India...?\
Regards
Jinson.
Hi All,
Right now I´m using 7 kannel, each kannel handle 1 GSM Modem, total 7 Modem.
1. Is this the right thing to do ?
2. Some time one of my kannel receive waited for bearerbox and the modem
hangs, What happen?
I'm using cvs-20090317
Thank You.
You must be going thru OPPC certification I'm guessing, I just finished this
nightmare. What I did to solve this exact problem was remove the
octstr_url_decode() calls from gw/meta_data.c, in function
meta_data_unpack
My line #'s are messed up so I can't give you the exact line #'s, but if
what
Hi,
Not on the same server. You should use many kannel instances in seperate
servers if you want to maximize throughput. But 7 GSM modems are nothing
significant that a single kannel cannot handle by itself.
(2) I don't quite understand what you mean. In any case if there is a problem
post
Hi LB,
One way to achieve this would be to set the source address of the SMS
you are sending as 999.
Although I think it could also be done using the callback_num field in
the Submit_SM PDU, it is an optional feature in SMPP 3.4 and hence not
all SMSCs may support it.
Latitude Berlin wrote:
Hi
10 matches
Mail list logo