: CM_CP_base.bin.Geom.dll;
Installed: Absent; Request: Local; Action: Null
MSI (s) (3C:58) [09:35:01:514]: Component:
CM_CP_pl3d.bin.PointLine3D.exe; Installed: Absent; Request: Local;
Action: Null
What could go wrong here, and what can I do to prevent it?
Rgds
Richard
, but there are so many error messages, that I
figured this would be the minimum required.
Next, I generated a new bundle from my application.
When I run it, it still doesn't fetch the feed from the webserver.
What am I missing?
Rgds
Richard
Am Donnerstag, den 30.10.2014, 15:14 + schrieb Hoover, Jacob
Thanks for the link.
I couldn't spot any reference to that feature in the youtube video.
On github I couldn't figure out if it is included in 3.9, as there is
only one 3.8 tag.
Is there any documentation or an example on how to use it, and how the
feed needs to be formatted?
Rgds
Richard
Am
to this list.
For other mailing lists on sourceforge this was never a problem.
Is this a known problem?
Is there a reason to filter out signed messages?
Rgds
Richard
--
___
WiX
should fetch it without me
having to provide a custom dll?
What led me to believe it was no longer necessary was this conversation:
https://www.mail-archive.com/wix-users@lists.sourceforge.net/msg62199.html
Rgds
Richard
Am Donnerstag, den 30.10.2014, 05:41 -0700 schrieb Phill Hogland:
The video
Richard
Am Montag, den 27.10.2014, 13:24 +0100 schrieb Richard Ulrich:
I found old references to clickthrough and DotUpdater. But they both
seem to be discontinued and abandoned.
Rgds
Richard
Am Donnerstag, den 23.10.2014, 13:50 +0200 schrieb Richard Ulrich:
Hi,
I switched to WiX
I'm using the WixUtilExtension, and specifically XmlFile, to conditionally
configure a list of items that eventually appear in a GUI combo box. I have
several check boxes on an installer dialog and when each is checked (true) I
want to write to an element into a configeration file. Initially
I'm new to Wix and having trouble including directories. I read about Heat and
Fragments and it appears I'm doing it by the example, but my directory and its
files are not getting included after the install.
My install.bat has:
c:\program files (x86)\wix toolset v3.8\bin\candle fragment.wxs
your example into an MSI and ran it and it works great.
Notepad.exe and Readme.txt installed. Remember if you are on a 64-bit system
you need to look in C:\Program Files (x86)\Example to find your installed files.
-Original Message-
From: Richard Silverstein [mailto:rsilverst
You need to reference the component/componentgroup from within a feature in
order for Wix to include it.
Feature Id=DefaultFeature Level=1
ComponentRef Id=ApplicationFiles/
ComponentGroupRef Id= SampleGroup /
/Feature
-Original Message-
From: Richard
Ok, I am working with Jonathan today in my day job capacity and I have an
understanding of PROBABLY what is happening. If the WiX-devs list is better for
this, let me know...
Based on the install logs and the way BURN appears to work, transforms seem a
bit limited in how BURN handles
.
Richard Norman
TechX - Technology eXperts
Technical Support Consulting
Phone: 559.464.5042
Web: http://on.fb.me/Ztd9ns
Sent from Windows Mail
From: Richard Norman
Sent: March 14, 2013 10:35 AM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Using
Hi
I'll swing this one around again before filing a bug report in case it was
missed during the holiday period.
Apologies if this is bad etiquette.
Richard Oliver
Developer, Systems Architecture, IT Development
Information Technology
The Open University
Berrill Building, Level 2 North
01908 6
it is
involved with the msi GUI. (huh?) I assumes a bootstrapper for WiX would be
like the bootstrapper for IS in that it could install prerequisites.
Thanks.
Richard
--
Master HTML5, CSS3, ASP.NET, MVC, AJAX, Knockout.js, Web API
is able to offer some assistance here or on stack overflow I'd much
appreciate it.
This is my work email so I may not respond until early January.
Happy Holidays
Thanks
Richard Oliver
Developer, Systems Architecture, IT Development
Information Technology
The Open University
Berrill Building, Level 2
I have an installer that we are currently using. I am using a
Bootstrapper. When I click on the installer it does nothing. The log
file shows the following.
[0690:1054][2012-10-24T08:43:02]: Burn v3.6.2221.0, path:
C:\Users\Owner6\Desktop\CurveImage-1_2_0-live.exe, cmdline: ''
Message-
From: Richard Compton [mailto:rich.comp...@curvedental.com]
Sent: Wednesday, October 24, 2012 9:41 AM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Wix problems
I have an installer that we are currently using. I am using a Bootstrapper.
When I click on the installer
.
Neil
-Original Message-
From: Richard Compton [mailto:rich.comp...@curvedental.com]
Sent: 24 October 2012 15:41
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Wix problems
I have an installer that we are currently using. I am using a Bootstrapper.
When I click
, are there any sub folders? It
may be as Neil suggested that you are using an outdated version (non-stable
release).
-Original Message-
From: Richard Compton [mailto:rich.comp...@curvedental.com]
Sent: Wednesday, October 24, 2012 10:58 AM
To: wix-users@lists.sourceforge.net
Subject: Re
Completely forgot about in-place upgrades, it's been so long since
I've done one! Now I just need to work out how to detect it
correctly...
Thanks
Richard
On 2 July 2012 17:03, Neil Sleightholm n...@x2systems.com wrote:
Instead of uninstalling why not do an upgrade to the SQL2005 instance
Hi
Currently one of our product uses Sql2005 express and I have created
an installer that can detect if there is an instance available and if
not install Sql2008R2. Is it possible to detect that the instance is
Sql2005 and uninstall that before installing Sql2008R2?
Richard Mayes
Mobile
I've been getting similar errors, however when I build again they seem
to go. I had it on a build a few versions back but then it seemed to
go and now has come back. As it builds fine the second time, it's just
an irritation for me...
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter
Why don't you just use the msbuild commandline if you already have the
wixproj? Just call msbuild in the same directory to the sln or wixproj
and it will find it.
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter: http://twitter.com/caveman_dick
On 27 June 2012 15:24, Dan Muller
the build
machine won't need to have wix installed. Check
http://wix.sourceforge.net/manual-wix3/daily_builds.htm for info on
how to to that.
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter: http://twitter.com/caveman_dick
On 27 June 2012 18:15, Dan Muller dmuller...@comcast.net wrote
Although I don't know what it was for I'm sure we don't actually need
it anymore! :)
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter: http://twitter.com/caveman_dick
On 25 June 2012 20:29, Rob Mensching r...@robmensching.com wrote:
GetShortFileName seems to be failing. Not sure how
()
at
Microsoft.Tools.WindowsInstallerXml.Extensions.UtilFinalizeHarvesterMutator.Mutate(Wix
wix)
at Microsoft.Tools.WindowsInstallerXml.Mutator.Mutate(Wix wix)
at Microsoft.Tools.WindowsInstallerXml.Tools.Heat.Run(String[] args)
Anyone know what this is and if/how I can resolve it?
Richard Mayes
Twitter: http
if I'm wrong. Doing it as a separate application will mean it will be
much easier to test though.
Richard Mayes
Mobile: +447740357239
On 29 May 2012 22:05, Werner Strydom werner.stry...@workshare.com wrote:
Hello,
Where can one get an end-to-end example of writing your own burn UI? I have
been
How about using ExePackage to run windows cmd and the command-line you
need to run with the /c switch
Richard Mayes
On 30 May 2012 16:17, Benjamin Bennett benbenn...@gmail.com wrote:
I am trying to use burn as bootstrapper.I have figured out how to
install sql server express and the third
useful and mean you
don't have to remove the /QS param.
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter: http://twitter.com/caveman_dick
On 25 May 2012 17:01, Benjamin Bennett benbenn...@gmail.com wrote:
Notes I seen this
http://sourceforge.net/mailarchive/forum.php?thread_name
I would assume that the exitcode values are not working correctly as I
force a reboot when installing Windows Installer 4.5 but I don't
bother checking the exit codes (omit the value attribute). Do you
really need to reboot after installing dotnet?
Richard Mayes
On 22 May 2012 08:17, Simon
it (sorry can't remember why).
It maybe worth removing the /q flag to check that dotnet is actually
being installed correctly.
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter: http://twitter.com/caveman_dick
On 22 May 2012 10:27, Simon Chromow simon.chro...@bewotec.de wrote:
I need
as that mentions REG_MULTI_SZ specifically.
Richard Mayes
Blog: http://blog.slinkysoftware.com
Twitter: http://twitter.com/caveman_dick
On 19 May 2012 08:54, Neil Sleightholm n...@x2systems.com wrote:
It looks like the documentation doesn't match this could you confirm which is
correct?
This http
to
use a bootstrapper to launch the two msi's one after the other. Take a look
at Burn the Wix bootstrapper
http://wix.sourceforge.net/manual-wix3/authoring_bundle_intro.htm
*Richard Mayes*
***Blog:* http://blog.slinkysoftware.com
*Twitter:* http://twitter.com/caveman_dick
On 18 May 2012 09:17
Variable=SQLServerInstalled /
I'm running the latest source on codeplex (3.6.2907)
Thanks
Richard
--
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and
threat landscape has
I have an installer that stops three services, but get an error:
MSI (s) (90:44) [12:11:17:558]: Executing op:
ActionStart(Name=StopServices,Description=Stopping
services,Template=Service: [1])
Action 12:11:17: StopServices. Stopping services
MSI (s) (90:44) [12:11:17:558]: Executing op:
I'm confused about best practices to use when deploying and maintaining
.NET *.config files via MSI. Our app uses the UnityContainer to manage type
injection and type configuration, some of which is environmental, meaning
type config changes at each customer site. This Unity configuration is
In article 4d52c165.4030...@kutulu.org,
Mike Edenfield kut...@kutulu.org writes:
The bootstrapper redistributable components don't appear to ship with
the v7.1 Windows SDK. This could be a result of MS deprecating Visual
Studio's setup packages in favor of using InstallShield (blech)
...and noone on the internet cares.
Folks, you should never configure your I am on vacation messages to
broadcast out to mailing lists.
--
The Direct3D Graphics Pipeline -- DirectX 9 draft available for download
http://legalizeadulthood.wordpress.com/the-direct3d-graphics-pipeline/
,
Richard
-Original Message-
From: Blair [mailto:os...@live.com]
Sent: Wednesday, November 24, 2010 9:57 PM
To: 'General discussion for Windows Installer XML toolset.'
Subject: Re: [WiX-users] Showing a dialog warning users they are upgrading.
Publish Dialog=WelcomeDlg Control=Next Event
in the list archives etc. Can anyone suggest what the problem is?
Regards,
Richard
Richard J Foster B.Eng
Software Engineer
Peek Traffic Corporation
Sustainable Solutions for Traffic Technologies - THINK PEEK
2906 Corporate Way
Palmetto, FL 34221
Phone: (941) 845-1223
In article blu111-ds20548e692caa0ab568b81ecd...@phx.gbl,
Blair os...@live.com writes:
Current sources are all on Codeplex now. Anything still on SF is stale.
OK, but trunk on codeplex is essentially empty.
--
The Direct3D Graphics Pipeline -- DirectX 9 draft available for download
In article e1penhv-0001v8...@shell.xmission.com,
Richard legal...@xmission.com writes:
In article blu111-ds20548e692caa0ab568b81ecd...@phx.gbl,
Blair os...@live.com writes:
Current sources are all on Codeplex now. Anything still on SF is stale.
OK, but trunk on codeplex
In article blu111-ds2a83513ffdb8daacacd...@phx.gbl,
Blair os...@live.com writes:
The docs in the sources are in source-code form, distributed between various
.XSD files in various directories and the code under src\chm.
OK, I'll have a look.
As I understand it, the failures in
In article aanlktinspsxlesglxcb3ab69sw3radsdbv68oe4wx...@mail.gmail.com,
Rob Mensching r...@robmensching.com writes:
Correct, the website publish process is really flimsy. It's been in place
since 2005 and heavily based on XSL which Fredrik (who built the process)
loves but I hate
In article
68c3161b99102f4ab682cfe6aa27c7f414cea...@ru-exstrcl1.ru.corp.acronis.com,
alexander.nevs...@acronis.com alexander.nevs...@acronis.com writes:
All links on documentation page (http://wix.sourceforge.net/manual-wix3/main.
htm) are broken! Is documentation moved somewhere else?
In article blu111-ds1a8e9f279888902a16435cd...@phx.gbl,
Blair os...@live.com writes:
What is considered best practice is to fail the installation attempt from
InstallExecuteSequence with an error message indicating that the previous
product must be removed first. This should then show up
In article 009c01cb2f4d$58a5a8b0$09f0fa...@gmail.com,
ALive aliv...@gmail.com writes:
If it is possible just add some Thread.Sleep(3000); or some WinAPI analog
like ::Sleep(DWORD); to simulate long process work, in this case you'll be
able to see the text.
I believe the progress text
In article aanlktikjvo5mb+pd9tz=a4cyjz+jobfnw6org0ytc...@mail.gmail.com,
James Poole w...@slowcommotion.com writes:
I seem to recall this being possible, but I am getting an error
Uninstallation of the patch package is not supported when I try to install
the second patch that supersedes
In article 1276315312254-5170676.p...@n2.nabble.com,
gapearce mr_gapea...@yahoo.com writes:
Can I do that? I'd like to spawn a different dialog from a spawned dialog.
You mean like a new modal dialog opened from an existing modal dialog?
Yeah, I think you can do that, although I don't
In article
097f198560bb9341b6781cb7946b81cc1833977...@va3diaxvs101.red001.local,
Carolina Zuqueto Amaral carolina.ama...@conv.com.br writes:
Is there a property what informs the user identifier Windows ?
The environment variable USERNAME is filled with the user's account
name.
--
The
Could you create an .msp to patch the original installer to add these files?
-Original Message-
From: Markus Karg [mailto:k...@quipsy.de]
Sent: 01 April 2010 10:30
To: General discussion for Windows Installer XML toolset.
Subject: [WiX-users] Prevent deinstallation
We have to write a
.
Subject: Re: [WiX-users] Prevent deinstallation
In theorey we could, but:
Will this solve the problem?
Will the user be able to see that the module was installed?
-Original Message-
From: Richard Horsley [mailto:richard.hors...@eicltd.com]
Sent: Donnerstag, 1. April 2010 11:42
do is have the
installer create shared files as well as the installed product and make one of
these an .inf file that contains the installed information that your support
desk can check to see if the product was EVER installed.
Richard Horsley
-Original Message-
From: Markus Karg
. Is
there any way to get heat to place all files from the same subfolder within the
same fragment/component, or is this not considered best practice?
Richard Horsley
DISCLAIMER
Please consider the environment before
this help information
heat dir directory path -out imp.wxs -template:product -scom -sreg -sfrag
-gg -suid
From: Richard Horsley [mailto:richard.hors...@eicltd.com]
Sent: Wed 3/31/2010 1:46 PM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Heat harvesting
' Version='1.2' Supersede='yes'
ComponentRef Id=component0/
/PatchFamily
/Fragment
/Wix
Help is much appreciated!
Richard
DISCLAIMER
Please consider the environment before printing this e-mail
/
/Feature
Media Id=1 EmbedCab=yes Cabinet=product.cab /
/Product
/Wix
I'm looking into your suggestion of making one patch for each msi and then
merging them to make one that will work for both. I'll let you know if I make
progress!
Thanks,
Richard
-Original Message-
From: Pally Sandher
patches to get ALL clients to 1.2 and
from there everything should work great.
Thanks for your help! This should now work for me going forwards.
Regards,
Richard
-Original Message-
From: Pally Sandher [mailto:pally.sand...@iesve.com]
Sent: 25 March 2010 10:53
To: General discussion
as it sees fit.
Regards,
Richard
-Original Message-
From: Markus Karg [mailto:k...@quipsy.de]
Sent: 25 March 2010 11:11
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] FW: Beginner's Question: 32 Bit MSI on 64 Bit OS
Dear WiX Community,
we need to write a MSI file that has
stop causing myself problems in the future,
so thanks a lot for your help!
Many thanks,
Richard
-Original Message-
From: Pally Sandher [mailto:pally.sand...@iesve.com]
Sent: 25 March 2010 11:59
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] MSI patching
, this is the defauly
behaviour of the standard x86 variables on x64 machines.
Richard
-Original Message-
From: Lodhiya, Harshil [mailto:harshil.lodh...@eclipsys.com]
Sent: 25 March 2010 12:12
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Beginner's Question: 32 Bit
Office - Helix Building, West Of Scotland Science Park,
Glasgow G20 0SP
Email Disclaimer
-Original Message-
From: Richard Horsley [mailto:richard.hors...@eicltd.com]
Sent: 25 March 2010 12:23
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] MSI patching
On 05/03/2010 02:00, Bob Arnson wrote:
On 3/4/2010 3:50 PM, Richard Fine wrote:
MSI (s) (48:34) [19:55:31:273]: Invoking remote custom action. DLL:
C:\Windows\Installer\MSIBFC7.tmp, Entrypoint: ExecXmlConfig
What's after that line? There should be a bit of logging if it couldn't
normally. There are no warning or debug messages of any
sort saying that XmlConfig can't do its thang. Yet the element doesn't
get removed. The timestamp on the config file changes, but the element
is still in there. WI thinks that the install succeeded.
Anyone know what's going on?
- Richard
You defined a configurable value, but haven't defined how/where that
configurable value is substituted into the data of the merge module
before being merged into the MSI.
Look at the Subsitution tag in the WiX schema reference as well as the
MSDN documentation on configurable merge modules:
In article 8b05023b1002110645p2eac15fbi79b2b478546cc...@mail.gmail.com,
Jake Boone jakeboon...@gmail.com writes:
No, the InstallUISequence.
In order to set properties in the UI sequence through a CA, the CA
must be an immediate CA.
Additionally, if you are setting properties in an
In article 11d0172190691a40ac32bae21f609be2047...@exchange2010.wedge.iita,
Harvey, John Ctr USAF Warfighter's Edge john.har...@wedge.hpc.mil
writes:
The Exit dialog happens at the very end after the InstallExecuteSequence. I=
s it not part of the InstallUISequence? Or is some of the UI
In article a4e1f201002090041k65c0d5ccl220bac2844df0...@mail.gmail.com,
Bimali Ponnamperuma bimal...@gmail.com writes:
Can anybody help me with the original question.
i,e, why does the 2nd dialog get propted every time even though it has
satisfied the condition 1 ?
Because you're not
In article blu111-ds5f00f8c0c0830bc25ae63cd...@phx.gbl,
Blair os...@live.com writes:
If the non-transformed instance of the product is installed, the Upgrade
table will never be evaluated because the FindRelatedProducts action skips
itself for maintenance mode operations. To some degree
In article 1264193852.10007.0.ca...@garman-linux,
Kevin Garman gar...@scadaware.com writes:
I have a multi-instance (transforms) installer and [...]
What exactly do you mean by this? What do the transforms do?
Its my experience that if you want to manipulate a base MSI with
transforms
In article
89030b4a18eccd45978a3a6b639d1f24030ac82...@fl01exmb01.trad.tradestation.com,
Tony Juricic tjuri...@tradestation.com writes:
At which point in the patching process are custom actions that are
executing the updated ones?
If they are custom actions that execute out of installed
What does the dialog do? What you are describing is not the right way
to do this, IMO. That's why its not working the way you want; Windows
Installer isn't designed to support this.
--
The Direct3D Graphics Pipeline -- DirectX 9 draft available for download
Use MsiProcessMessage to display message boxes, not MessageBox.
--
The Direct3D Graphics Pipeline -- DirectX 9 draft available for download
http://legalizeadulthood.wordpress.com/the-direct3d-graphics-pipeline/
Legalize Adulthood! http://legalizeadulthood.wordpress.com
In article 4d6ef6e1711cde4e93d1f1e591a614d6345...@nl1mail0302.global.sdl.corp,
Igor Paniushkin ipaniush...@sdl.com writes:
It is not really related to your question, but I had a question about
popup message box from custom action and I got an answer from Bob
Arnson:
Set a property in
You create /local/ accounts and groups, not domain accounts. If you
also need domain permissions, then your installation instructions
specify what local accounts/groups need to be added to what domain
group.
--
The Direct3D Graphics Pipeline -- DirectX 9 draft available for download
In article 481222.60726...@web30401.mail.mud.yahoo.com,
Sankaranarayanan loony...@yahoo.com writes:
For validating the fields in Custom UI for empty / null values - I am calling
a Custom action on DoAction event of the Next Button and spawing a new dialo
g if all the input values are
In article
fc8c44cef7807d4bbb771659436fd8445e39b60...@wa1annxvs011.redppe.local,
Baris Taze bt...@microsoft.com writes:
Is there a way to change the style of a Control in WixUI?
For example, background color, foreground color, font size, font type (bold,
italic), font name (Tahoma,
shrug I don't think I would try to cram this into the installer.
If the installer isn't going to change the group membership, then it
shouldn't be gathering the information to query the group membeship.
Do it after installation time with a standalone configuration
utility. That way they can
If you have special security needs, the best approach is to create a user
or group with exactly the permissions that you need and have your code run
as that user or as a member of that group.
When you uninstall your application you remove the created user/group.
--
The Direct3D Graphics
Well, first of all, you know that you shouldn't be asking for
usernames and passwords, right? You should be creating accounts with
*exactly* the permissions you need and setting your code to run under
those credentials. When your application is removed, you remove the
created user. This is
In article
d91a1dd8a8f2ba459644b8f3b7e517ddad079cd...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
All -
Is there a way to refresh a dialog when checking a checkbox?
I have a dialog with a checkbox control on it to give the user the ability to
In article bay112-w17f0787cea4f94922e1829c7...@phx.gbl,
Uday Kumar uda...@hotmail.com writes:
In wix-msi how can I pass the values between two dialog boxes. I will
select one item from combo box of first screen/dialog, based on the
selection, secon d screen combo box should populate. How
For the benefit of others, this appears to be by design.
By default, your application is bound to the old runtime, even though
the merge modules get updated (so you can't distribute the old runtime
unless you saved a copy of the merge modules before you updated).
However, if you define
In article bay122-ds39e8ccf0f56e8d035b5c9cd...@phx.gbl,
Blair os...@live.com writes:
Which is exactly the reason so many people ship the policies when they
install the runtimes.
Everything I saw describing how to use the merge modules with WiX
recommended against using the policy MSMs.
OK, I did a little testing and the results surprised me because the
working solution goes against the advice of not including the policy
MSM.
Scenarios are as follows, all on Windows XP SP 3:
- No MSMs, run the vcredist_x86.exe, install my application, my app launches
- Payload MSM, install my
In article
682e56117f9ba0419d5247669e3f742d836478e...@invsfoxxchmbx02.corp.com,
Wilson, Phil phil.wil...@wonderware.com writes:
Richard would have to look at his code's manifest and see what
redirection exists on the machine for that particular runtime Dll.
Hmm OK, this is giving
In article bay122-ds7e44a9b780fe6af49ee05cd...@phx.gbl,
Blair os...@live.com writes:
If you are forced by any other constraint to elevate your setup, make it a
perMachine installation (especially on platforms without UAC) and install
the runtime in SxS shared mode (either MSM or EXE
In article bay122-ds449eed411daf09a4ab577cd...@phx.gbl,
Blair os...@live.com writes:
To keep your own sanity and make sure that repairs, etc. don't mess things
up, it is best to do what the built-in standard actions effectively do and
have an immediate CA or two (the only one(s) you ever
In article 2ca537e1091016j30f5b672k13d256cece2ba...@mail.gmail.com,
Tony yellowjacketl...@gmail.com writes:
I know deferred actions only have access to CustomActionData property,
what about rollback actions? Do either have access to other session
data like features, etc?
Rollback
In article 2ca537e10911101230v21ed97e1sabffc232fc58b...@mail.gmail.com,
Tony yellowjacketl...@gmail.com writes:
During rollback, all actions executed since the InstallInitialize are
run again in reverse order (assuming conditions are met), correct?
And the Rollback property is set. Are
OK, so I need to deploy the VS 2008 C++ runtime (w/ATL security fix)
and I'm reading the documentation in Visual Studio that says that
using the merge modules will install the runtime as side-by-side
assemblies. Further, it says that this will require administrative
priveleges in order to install
In article 162de7480911021842v75b9ecc1j99622cf647134...@mail.gmail.com,
Wesley W. Terpstra wes...@terpstra.ca writes:
On Mon, Nov 2, 2009 at 11:41 PM, Richard legal...@xmission.com wrote:
In article 162de7480911020831o4b123747xc933d27b4fbf8...@mail.gmail.com,
=A0 =A0Wesley W. Terpstra
In article 162de7480911020831o4b123747xc933d27b4fbf8...@mail.gmail.com,
Wesley W. Terpstra wes...@terpstra.ca writes:
[...] For such a big
savings in download-time I think that's a reasonable trade-off.
Have you been receiving complaints about download times?
Doing the simplest thing
In article
d91a1dd8a8f2ba459644b8f3b7e517ddac0ee4e...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
My application is installed at an enterprise level where there are
separate S QL servers, SSRS servers and IIS servers and even if you have
admin
In article
d91a1dd8a8f2ba459644b8f3b7e517ddac0ee4e...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
The lengthy CA validates the users credentials [...]
Why does your application need a user's credentials?
If your application needs to do something
In article
d91a1dd8a8f2ba459644b8f3b7e517ddac0ee4e...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
!-- In the TestDlg I do the following--
Control Id=TestButton Type=PushButton X=100 Y=100 Width=66
Height=18 Text=Test TabSkip=no Default=yes
In article
d91a1dd8a8f2ba459644b8f3b7e517ddac0ee4e...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
Richard - Sorry I didn't see your post until now. The order they
are declared in is the order they are assigned as can be seen in the
ControlEvent
In article
d91a1dd8a8f2ba459644b8f3b7e517ddac0ee4e...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
Is there some simpler method to allow me to put up a Please wait
dialog while a long CA is running and then have it taken down.
Let me take a step
In article
d91a1dd8a8f2ba459644b8f3b7e517ddac0ee4e...@exvmbx015-4.exch015.msoutlookonline.net,
Tom Crozier tcroz...@rackwise.com writes:
As far as the async goes there are 2 synchronous methods for calling
CA's Che ck and Ignore. And there are 2 async methods asyncWait and
asyncNoWait.
In article
5e7723298293ea4b8c5fac913740a9cc212b5...@tk5ex14mbxw652.wingroup.windeploy.ntdev.microsoft.com,
Dan Giambalvo danie...@microsoft.com writes:
During our InstallExecuteSequence we decrement an install count for
the user via a Custom Action.
What does the install count mean?
1 - 100 of 526 matches
Mail list logo