>From the cfgadm -al output it appears there is no storage available to the 
>HBA. If there was, it would look something like this:

Ap_Id                          Type         Receptacle   Occupant     Condition
c0                             scsi-bus     connected    configured   unknown
c0::dsk/c0t6d0                 CD-ROM       connected    configured   unknown
c1                             fc-private   connected    configured   unknown
c1::21000020379cb9bb           disk         connected    configured   unknown
c2                             scsi-bus     connected    unconfigured unknown
c5                             fc-fabric    connected    unconfigured unknown
c5::100000e0024302c0           tape         connected    unconfigured unknown
c5::210000008708d98d           disk         connected    unconfigured unknown
c5::21000020372a4076           disk         connected    unconfigured unknown
c5::50020f230000588a           disk         connected    unconfigured unknown
c5::50060e8014422e51           disk         connected    unconfigured unknown
c5::50060e8014422e61           disk         connected    unconfigured unknown
c5::50060e8014422e71           disk         connected    unconfigured unknown
c5::50060e8014422e76           disk         connected    unconfigured unknown

Double check that the McData, with no zoning, will allow devices to talk to 
each other. On QLogic FC switches there is a switch parameter called "default 
zoning visibility" that controls if devices can talk when there is no zone.
 
 
This message posted from opensolaris.org
_______________________________________________
storage-discuss mailing list
storage-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/storage-discuss