>From the cfgadm -al output it appears there is no storage available to the >HBA. If there was, it would look something like this:
Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t6d0 CD-ROM connected configured unknown c1 fc-private connected configured unknown c1::21000020379cb9bb disk connected configured unknown c2 scsi-bus connected unconfigured unknown c5 fc-fabric connected unconfigured unknown c5::100000e0024302c0 tape connected unconfigured unknown c5::210000008708d98d disk connected unconfigured unknown c5::21000020372a4076 disk connected unconfigured unknown c5::50020f230000588a disk connected unconfigured unknown c5::50060e8014422e51 disk connected unconfigured unknown c5::50060e8014422e61 disk connected unconfigured unknown c5::50060e8014422e71 disk connected unconfigured unknown c5::50060e8014422e76 disk connected unconfigured unknown Double check that the McData, with no zoning, will allow devices to talk to each other. On QLogic FC switches there is a switch parameter called "default zoning visibility" that controls if devices can talk when there is no zone. This message posted from opensolaris.org _______________________________________________ storage-discuss mailing list storage-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/storage-discuss