I have the same problem (kernel 2.6.31-17-generic, xserver-xorg-video-intel 
2:2.9.0-1ubuntu):
a...@biblioteket:~$ sudo dmidecode -s system-product-name
Macmini1,1
a...@biblioteket:~$ sudo lspci -vvs 00:2.0
00:02.0 VGA compatible controller: Intel Corporation Mobile 945GM/GMS, 
943/940GML Express Integrated Graphics Controller (rev 03)
        Subsystem: Intel Corporation Device 7270
        Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- 
Stepping- SERR- FastB2B- DisINTx-
        Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=fast >TAbort- <TAbort- 
<MAbort- >SERR- <PERR- INTx-
        Latency: 0
        Interrupt: pin A routed to IRQ 16
        Region 0: Memory at 90380000 (32-bit, non-prefetchable) [size=512K]
        Region 1: I/O ports at 20f0 [size=8]
        Region 2: Memory at 80000000 (32-bit, prefetchable) [size=256M]
        Region 3: Memory at 90400000 (32-bit, non-prefetchable) [size=256K]
        Capabilities: [90] Message Signalled Interrupts: Mask- 64bit- Queue=0/0 
Enable-
                Address: 00000000  Data: 0000
        Capabilities: [d0] Power Management version 2
                Flags: PMEClk- DSI+ D1- D2- AuxCurrent=0mA 
PME(D0-,D1-,D2-,D3hot-,D3cold-)
                Status: D0 PME-Enable- DSel=0 DScale=0 PME-
        Kernel driver in use: i915
        Kernel modules: i915

a...@biblioteket:~$


a...@biblioteket:~$ sudo get-edid | parse-edid
parse-edid: parse-edid version 2.0.0
get-edid: get-edid version 2.0.0

        Performing real mode VBE call
        Interrupt 0x10 ax=0x4f00 bx=0x0 cx=0x0
        Function supported
        Call successful

        VBE version 300
        VBE string at 0x11100 "Intel(r) 82945GM Chipset Family Graphics Chip 
Accelerated VGA BIOS"

VBE/DDC service about to be called
        Report DDC capabilities

        Performing real mode VBE call
        Interrupt 0x10 ax=0x4f15 bx=0x0 cx=0x0
        Function supported
        Call successful

        Monitor and video card combination does not support DDC1 transfers
        Monitor and video card combination supports DDC2 transfers
        0 seconds per 128 byte EDID block transfer
        Screen is not blanked during DDC transfer

Reading next EDID block

VBE/DDC service about to be called
        Read EDID

        Performing real mode VBE call
        Interrupt 0x10 ax=0x4f15 bx=0x1 cx=0x0
        Function supported
        Call successful

parse-edid: EDID checksum passed.

        # EDID version 1 revision 3
Section "Monitor"
        # Block type: 2:0 3:ff
        # Block type: 2:0 3:fd
        # Block type: 2:0 3:fc
        Identifier "DELL SP2309W"
        VendorName "DEL"
        ModelName "DELL SP2309W"
        # Block type: 2:0 3:ff
        # Block type: 2:0 3:fd
        HorizSync 30-92
        VertRefresh 56-85
        # Max dot clock (video bandwidth) 170 MHz
        # Block type: 2:0 3:fc
        # DPMS capabilities: Active off:yes  Suspend:yes  Standby:yes

        Mode    "2048x1152"     # vfreq 59.909Hz, hfreq 70.992kHz
                DotClock        156.750000
                HTimings        2048 2096 2128 2208
                VTimings        1152 1155 1160 1185
                Flags   "-HSync" "+VSync"
        EndMode
        # Block type: 2:0 3:ff
        # Block type: 2:0 3:fd
        # Block type: 2:0 3:fc
EndSection
a...@biblioteket:~$

-- 
[i915] 23" external Dell VGA monitor at full resolution not possible with 
Desktop Effects enabled
https://bugs.launchpad.net/bugs/426380
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to