On Sun, Jan 05, 2003 at 04:46:47PM +0100, Anders Torger wrote:
>
> Here is a patch against rme96.c
>
snd_rme96_capture_spdif_open(snd_pcm_substream_t *substream)
[...]
+ runtime->hw = snd_rme96_capture_spdif_info;
+ if ((rate = snd_rme96_capture_getrate(rme96, &isadat)) > 0) {
+ if (isadat) {
+ return -EIO;
+ }
+ runtime->hw.rates = snd_rme96_ratecode(rate);
+ runtime->hw.rate_min = rate;
+ runtime->hw.rate_max = rate;
+ }
You were changing sample rates in snd_rme96_capture_spdif_open. Isn't it too
late there? Looks like capturing with wrong sample rates is now possible?
Wouldn't this be better placed in the snd_rme96_capture_hw_params?
martin
--