# dmidecode 2.9
SMBIOS 2.4 present.
30 structures occupying 1031 bytes.
Table at 0x000DF010.

Handle 0x0000, DMI type 0, 24 bytes
BIOS Information
	Vendor: TOSHIBA
	Version: V5.00   
	Release Date: 12/02/2008
	Address: 0xE76F0
	Runtime Size: 100624 bytes
	ROM Size: 1024 kB
	Characteristics:
		ISA is supported
		PCI is supported
		PC Card (PCMCIA) is supported
		PNP is supported
		BIOS is upgradeable
		BIOS shadowing is allowed
		ESCD support is available
		Boot from CD is supported
		ACPI is supported
		USB legacy is supported
		BIOS boot specification is supported
		Targeted content distribution is supported

Handle 0x0001, DMI type 1, 27 bytes
System Information
	Manufacturer: TOSHIBA
	Product Name: Satellite Pro U300
	Version: PSU31E-00T019G3
	Serial Number: 97052994W
	UUID: 40E2B8F8-C3F3-DB11-BD40-001B2498D56F
	Wake-up Type: Power Switch
	SKU Number: Not Specified
	Family: Not Specified

Handle 0x0002, DMI type 2, 8 bytes
Base Board Information
	Manufacturer: TOSHIBA
	Product Name: Satellite Pro U300
	Version: Not Applicable                  
	Serial Number: 1234567890                      

Handle 0x0003, DMI type 3, 17 bytes
Chassis Information
	Manufacturer: TOSHIBA
	Type: Notebook
	Lock: Not Present
	Version: N/A
	Serial Number: None
	Asset Tag:                                 
	Boot-up State: Safe
	Power Supply State: Safe
	Thermal State: Safe
	Security Status: None
	OEM Information: 0x42553153

Handle 0x0004, DMI type 4, 35 bytes
Processor Information
	Socket Designation: U2E1
	Type: Central Processor
	Family: <OUT OF SPEC>
	Manufacturer: Intel
	ID: FD 06 00 00 FF FB EB BF
	Version: CPU Version
	Voltage: 3.3 V
	External Clock: 200 MHz
	Max Speed: 4096 MHz
	Current Speed: 2000 MHz
	Status: Populated, Enabled
	Upgrade: ZIF Socket
	L1 Cache Handle: 0x0005
	L2 Cache Handle: 0x0006
	L3 Cache Handle: Not Provided
	Serial Number: Not Specified
	Asset Tag: Not Specified
	Part Number: Not Specified

Handle 0x0005, DMI type 7, 19 bytes
Cache Information
	Socket Designation: L1 Cache
	Configuration: Enabled, Socketed, Level 1
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 64 KB
	Maximum Size: 64 KB
	Supported SRAM Types:
		Burst
		Pipeline Burst
		Asynchronous
	Installed SRAM Type: Asynchronous
	Speed: Unknown
	Error Correction Type: Unknown
	System Type: Unknown
	Associativity: Unknown

Handle 0x0006, DMI type 7, 19 bytes
Cache Information
	Socket Designation: L2 Cache
	Configuration: Enabled, Socketed, Level 2
	Operational Mode: Write Back
	Location: Internal
	Installed Size: 2048 KB
	Maximum Size: 4096 KB
	Supported SRAM Types:
		Burst
		Pipeline Burst
		Asynchronous
	Installed SRAM Type: Burst
	Speed: Unknown
	Error Correction Type: Unknown
	System Type: Unknown
	Associativity: Unknown

Handle 0x0007, DMI type 9, 13 bytes
System Slot Information
	Designation: PCI Slot J8B3
	Type: 32-bit PCI
	Current Usage: Unknown
	Length: Long
	ID: 0
	Characteristics:
		5.0 V is provided
		3.3 V is provided

Handle 0x0008, DMI type 10, 6 bytes
On Board Device Information
	Type: Sound
	Status: Disabled
	Description: HD-Audio

Handle 0x0009, DMI type 11, 5 bytes
OEM Strings
	String 1: SSU3100T019G3,H07827EN

Handle 0x000A, DMI type 12, 5 bytes
System Configuration Options
	Option 1: Jumper settings can be described here.

Handle 0x000B, DMI type 15, 29 bytes
System Event Log
	Area Length: 16 bytes
	Header Start Offset: 0x0000
	Header Length: 16 bytes
	Data Start Offset: 0x0010
	Access Method: General-purpose non-volatile data functions
	Access Address: 0x0000
	Status: Valid, Not Full
	Change Token: 0x00000085
	Header Format: Type 1
	Supported Log Type Descriptors: 3
	Descriptor 1: POST error
	Data Format 1: POST results bitmap
	Descriptor 2: Single-bit ECC memory error
	Data Format 2: Multiple-event
	Descriptor 3: Multi-bit ECC memory error
	Data Format 3: Multiple-event

Handle 0x000C, DMI type 16, 15 bytes
Physical Memory Array
	Location: System Board Or Motherboard
	Use: System Memory
	Error Correction Type: None
	Maximum Capacity: 4 GB
	Error Information Handle: Not Provided
	Number Of Devices: 2

Handle 0x000D, DMI type 17, 27 bytes
Memory Device
	Array Handle: 0x000C
	Error Information Handle: No Error
	Total Width: 64 bits
	Data Width: 64 bits
	Size: 1024 MB
	Form Factor: SODIMM
	Set: 1
	Locator: M1
	Bank Locator: Bank 0
	Type: DDR2
	Type Detail: Synchronous
	Speed: 667 MHz (1.5 ns)
	Manufacturer: Mfg 0
	Serial Number: 1234-B0
	Asset Tag: Not Specified
	Part Number: SODIMM000

Handle 0x000E, DMI type 17, 27 bytes
Memory Device
	Array Handle: 0x000C
	Error Information Handle: No Error
	Total Width: 64 bits
	Data Width: 64 bits
	Size: 1024 MB
	Form Factor: SODIMM
	Set: 1
	Locator: M2
	Bank Locator: Bank 1
	Type: DDR2
	Type Detail: Synchronous
	Speed: 667 MHz (1.5 ns)
	Manufacturer: Mfg 1
	Serial Number: 1234-B1
	Asset Tag: Not Specified
	Part Number: SODIMM001

Handle 0x000F, DMI type 19, 15 bytes
Memory Array Mapped Address
	Starting Address: 0x00000000000
	Ending Address: 0x0007FFFFFFF
	Range Size: 2 GB
	Physical Array Handle: 0x000C
	Partition Width: 0

Handle 0x0010, DMI type 20, 19 bytes
Memory Device Mapped Address
	Starting Address: 0x00000000000
	Ending Address: 0x0003FFFFFFF
	Range Size: 1 GB
	Physical Device Handle: 0x000D
	Memory Array Mapped Address Handle: 0x000F
	Partition Row Position: Unknown
	Interleave Position: Unknown
	Interleaved Data Depth: Unknown

Handle 0x0011, DMI type 20, 19 bytes
Memory Device Mapped Address
	Starting Address: 0x00040000000
	Ending Address: 0x0007FFFFFFF
	Range Size: 1 GB
	Physical Device Handle: 0x000E
	Memory Array Mapped Address Handle: 0x000F
	Partition Row Position: Unknown
	Interleave Position: Unknown
	Interleaved Data Depth: Unknown

Handle 0x0012, DMI type 23, 13 bytes
System Reset
	Status: Enabled
	Watchdog Timer: Present
	Boot Option: Do Not Reboot
	Boot Option On Limit: Do Not Reboot
	Reset Count: Unknown
	Reset Limit: Unknown
	Timer Interval: Unknown
	Timeout: Unknown

Handle 0x0013, DMI type 24, 5 bytes
Hardware Security
	Power-On Password Status: Disabled
	Keyboard Password Status: Unknown
	Administrator Password Status: Disabled
	Front Panel Reset Status: Unknown

Handle 0x0014, DMI type 25, 9 bytes
	System Power Controls
	Next Scheduled Power-on: 12-31 23:59:59

Handle 0x0015, DMI type 26, 20 bytes
Voltage Probe
	Description: Voltage Probe
	Location: Processor
	Status: OK
	Maximum Value: Unknown
	Minimum Value: Unknown
	Resolution: Unknown
	Tolerance: Unknown
	Accuracy: Unknown
	OEM-specific Information: 0x00000000

Handle 0x0016, DMI type 27, 12 bytes
Cooling Device
	Temperature Probe Handle: 0x0017
	Type: Fan
	Status: OK
	OEM-specific Information: 0x00000000

Handle 0x0017, DMI type 28, 20 bytes
Temperature Probe
	Description: Temperature Probe
	Location: Processor
	Status: OK
	Maximum Value: Unknown
	Minimum Value Unknown
	Resolution: Unknown
	Tolerance: Unknown
	Accuracy: Unknown
	OEM-specific Information: 0x00000000

Handle 0x0018, DMI type 29, 20 bytes
Electrical Current Probe
	Description: Electrical Current Probe
	Location: Processor
	Status: OK
	Maximum Value: Unknown
	Minimum Value: Unknown
	Resolution: Unknown
	Tolerance: Unknown
	Accuracy: Unknown
	OEM-specific Information: 0x00000000

Handle 0x0019, DMI type 30, 6 bytes
Out-of-band Remote Access
	Manufacturer Name: Intel
	Inbound Connection: Enabled
	Outbound Connection: Disabled

Handle 0x001A, DMI type 32, 20 bytes
System Boot Information
	Status: <OUT OF SPEC>

Handle 0x001B, DMI type 129, 10 bytes
OEM-specific Type
	Header and Data:
		81 0A 1B 00 01 01 02 01 01 02
	Strings:
		Intel_ASF
		Intel_ASF_001

Handle 0x001C, DMI type 136, 6 bytes
OEM-specific Type
	Header and Data:
		88 06 1C 00 5A 5A

Handle 0x001D, DMI type 127, 4 bytes
End Of Table