yes, I did.
But it doesn't work for me.
I've just realized I'm getting warnings when I load the net list:

2: Warning! net "unnamed_net10" is shorted to net "unnamed_net1"
3: Warning! net "unnamed_net10" is shorted to net "unnamed_net1"
4: Warning! net "unnamed_net9" is shorted to net "unnamed_net5"
5: Warning! net "unnamed_net9" is shorted to net "unnamed_net5"
6: Warning! net "unnamed_net8" is shorted to net "unnamed_net2"
7: Warning! net "unnamed_net8" is shorted to net "unnamed_net2"
8: Warning! net "unnamed_net7" is shorted to net "unnamed_net3"
9: Warning! net "unnamed_net7" is shorted to net "unnamed_net3"
10: Warning! net "unnamed_net6" is shorted to net "unnamed_net4"
11: Warning! net "unnamed_net6" is shorted to net "unnamed_net4"
12: Warning! net "unnamed_net5" is shorted to net "unnamed_net9"
13: Warning! net "unnamed_net4" is shorted to net "unnamed_net6"
14: Warning! net "unnamed_net3" is shorted to net "unnamed_net7"
15: Warning! net "unnamed_net2" is shorted to net "unnamed_net8"
16: Warning! net "unnamed_net1" is shorted to net "unnamed_net10"

That may be a hint of the problem.

Thank you very much.

2006/11/3, John Luciani <[EMAIL PROTECTED]>:
On 11/3/06, Giorgenes Gelatti <[EMAIL PROTECTED]> wrote:
> What do you mean "on grid"?

gschem has a grid set at 100 gschem-units. For a connection to be made
pins have to have the active end on the grid.

Your schematic is on grid.

Did you load the netlist file prior to running the optimize command?
Your schematic, PCB and netlist file look correct and they worked for
me.

I did the following:

1. File->Load Layout
2. File->Load netlist File
3. Pressed the 'O' key (optimize rats nest).

(* jcl *)

--
http://www.luciani.org


_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user



_______________________________________________
geda-user mailing list
geda-user@moria.seul.org
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user

Reply via email to