On Jan 9, 2007, at 10:38 AM, John Luciani wrote:
On 09 Jan 2007 18:13:35 +0100, David Kuehling <[EMAIL PROTECTED]> wrote:
Hi,
I used both (analog) GND and PGND symbols in my layout. Now after
running gschem2pcb and loading the netlist file I see that those
symbols
create two separated nets.
Still I want to connect GND and PGND somewhere in my layout without
making the DRC complain. I tried to add a connection between GND and
PGND in my schematic, but that doesn't help.
If you attach two named nets to a component pin they will connect.
See my simple example below.
A net with two names should throw a Big Fat DRC Error!
-a
_______________________________________________
geda-user mailing list
geda-user@moria.seul.org