Hi Greg, I use BONDS and Apex slides as well. What we do with tissue that washes (usually heavy tumor and some harsher stains like CD34) is leave the tissue unbaked at room temp for 12 hours and then bake at 60 degrees for 30 minutes. I don't know if you are including your control tissue on the same slide (we do) but we also cut a separate slide with just patient sections and that seems to help with extra paraffin runoff from the control tissue underneath the patient tissue. We've been doing this successfully for years. I hope this is helpful, I totally understand your frustration!
Kari M Simeone Histology/Immunohistochemistry Specialist Supervisor ________________________________________ From: histonet-requ...@lists.utsouthwestern.edu [histonet-requ...@lists.utsouthwestern.edu] Sent: Thursday, July 13, 2017 1:00 PM To: histonet@lists.utsouthwestern.edu Subject: Histonet Digest, Vol 164, Issue 9 Send Histonet mailing list submissions to histonet@lists.utsouthwestern.edu To subscribe or unsubscribe via the World Wide Web, visit https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.utsouthwestern.edu_mailman_listinfo_histonet&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=gVV45__1yJfu6axbr8oxcPYBvFX1MiI_GOD2r2Kpv_g&e= or, via email, send a message with subject or body 'help' to histonet-requ...@lists.utsouthwestern.edu You can reach the person managing the list at histonet-ow...@lists.utsouthwestern.edu When replying, please edit your Subject line so it is more specific than "Re: Contents of Histonet digest..." Today's Topics: 1. Re: Section adherence issues (IHC) (Walter Benton) 2. Permanent/Full Time Histotech Job in Panama City, FL (Melissa Owens) 3. New Lab Related Blog Post (Lester Raff MD) ---------------------------------------------------------------------- Message: 1 Date: Wed, 12 Jul 2017 17:37:38 +0000 From: Walter Benton <wben...@cua.md> To: "Hujet, Matthew" <https://urldefense.proofpoint.com/v2/url?u=http-3A__Matthew.Hujet-40ssmhealth.com&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=F1TSqbvH_gNcZCNxbzfj4YvTHIhCktr_3GoGHgornJM&e= >, Greg Dobbin <https://urldefense.proofpoint.com/v2/url?u=http-3A__greg.dobbin-40gmail.com&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=VTefCjSt2cBRdRq7WmFsFV-QelqPZmBxp9PaxdoXh20&e= > Cc: "kgevele...@ihis.org" <kgevele...@ihis.org>, "histonet@lists.utsouthwestern.edu" <histonet@lists.utsouthwestern.edu> Subject: Re: [Histonet] Section adherence issues (IHC) Message-ID: <816e042155824c4193f79c50c1461...@mail01.gcu-MD.local> Content-Type: text/plain; charset="us-ascii" Thanks. This is helpful information. -----Original Message----- From: Hujet, Matthew [mailto:matthew.hu...@ssmhealth.com] Sent: Wednesday, July 12, 2017 1:35 PM To: Walter Benton <wben...@cua.md>; Greg Dobbin <https://urldefense.proofpoint.com/v2/url?u=http-3A__greg.dobbin-40gmail.com&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=VTefCjSt2cBRdRq7WmFsFV-QelqPZmBxp9PaxdoXh20&e= > Cc: kgevele...@ihis.org; histonet@lists.utsouthwestern.edu Subject: RE: [Histonet] Section adherence issues (IHC) We have had really good luck with both the TOMO and Millennia 2000 adhesion slides. We initially tried using the TOMO slides for everything (IHC, special stains, and H&E's), but found that there was too much background staining on the specials and H&E's. For IHC, the TOMO slides were great. We then switched to the Millennia 2000 for everything, and they have been working really well across the board. With regards to just IHC, I personally feel that the TOMO slides are better, but if you only want one type of glass in your lab, the Millennia 2000 are the way to go. Matthew Hujet Histology Technical Specialist SSM Health St. Mary's Hospital - Madison 700 S. Park St. Madison, WI 53715 Please note my new email address: matthew.hu...@ssmhealth.com -----Original Message----- From: Walter Benton [mailto:wben...@cua.md] Sent: Wednesday, July 12, 2017 10:34 AM To: Greg Dobbin <https://urldefense.proofpoint.com/v2/url?u=http-3A__greg.dobbin-40gmail.com&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=VTefCjSt2cBRdRq7WmFsFV-QelqPZmBxp9PaxdoXh20&e= > Cc: kgevele...@ihis.org; histonet@lists.utsouthwestern.edu Subject: Re: [Histonet] Section adherence issues (IHC) Greg, We are running into a similar issue on the Biocare Nemesis platform and the support there suggest humidity to be the issue. Our sections stay adhered to the slides through depar, antigen retrieval, but appear to fall off during the staining process. It is not consistent. We are going to try some other slides and see if the issue persists. I'd be interested to hear your findings and resolution. Walter Benton HT(ASCP)QIHC Lab Operations Manager Chesapeake Urology Associates 806 Landmark Drive, Suite 127 Glen Burnie, MD 21061 -----Original Message----- From: Greg Dobbin via Histonet [mailto:histonet@lists.utsouthwestern.edu] Sent: Wednesday, July 12, 2017 11:09 AM To: histonet@lists.utsouthwestern.edu Cc: kgevele...@ihis.org Subject: [Histonet] Section adherence issues (IHC) Hi Folks, I haven't been on here much lately but it is nice to know that we are all here for each other when needed! My problem is section adherence during IHC staining. And it is not all of the time it is intermittent; so not all of the time and not on all slides when it does occur. Background: We have a Bond-III immunostainer and we use the Leica Apex charged slides for our IHC stains. We have no additives in our water baths. Our sections drain in a stand and then any trapped water under the section is either flicked or wicked away as needed prior to placing the slides in a rack in a 60 C oven for 30 mins prior to staining. We do not do on board baking (primarily because on board baking is only 10 mins long and with the section lifting issue we want longer). Some of the specimen types are more susceptible it would seem. Cervix LEEP specimens tend to be bad, we use a 4mm punch to obtain some of our control tissue and so the breast tissue we use for Myosin Heavy Chain seems to be a bad one and sometimes our ER/PR control sections (but not always). Fine needle cores where a lot of tumour is present tend to be bad (again not always). We have tried baking longer, we turn ourselves inside out trying to get all of the water out from under the sections, we have tried charged slides from another manufacturer. I have looked at the HIER protocols and none are extraordinary in nature. We use very clean covertiles (no scratches or blemishes). Our specimens are fixed for 24hrs before processing. We use the same slides for Special Stains and don't have this issue there. I need some new suggestions to try! All ideas welcome. Cheers, Greg -- *Greg Dobbin* 1205 Pleasant Grove Rd RR#2 York, PE C0A 1P0 *Everything in moderation...even moderation itself**!* _______________________________________________ Histonet mailing list Histonet@lists.utsouthwestern.edu https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.utsouthwestern.edu_mailman_listinfo_histonet&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=gVV45__1yJfu6axbr8oxcPYBvFX1MiI_GOD2r2Kpv_g&e= CONFIDENTIALITY NOTICE: The information contained in this electronic message is intended solely for the personal and confidential use of the designated recipient(s) named above and may contain information that is protected from disclosure under applicable law. If you are not the intended recipient, or the employee or agent responsible for delivering it to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this transmission is strictly prohibited. If you have received this transmission in error, please notify the transmitting person/department immediately by email or telephone (410) 581-5881 and delete the message without making a copy. ________________________________ Confidentiality Notice: This email message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply email and destroy all copies of the original message. CONFIDENTIALITY NOTICE: The information contained in this electronic message is intended solely for the personal and confidential use of the designated recipient(s) named above and may contain information that is protected from disclosure under applicable law. If you are not the intended recipient, or the employee or agent responsible for delivering it to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this transmission is strictly prohibited. If you have received this transmission in error, please notify the transmitting person/department immediately by email or telephone (410) 581-5881 and delete the message without making a copy. ------------------------------ Message: 2 Date: Wed, 12 Jul 2017 19:59:14 +0000 From: Melissa Owens <meli...@alliedsearchpartners.com> To: "histonet@lists.utsouthwestern.edu" <histonet@lists.utsouthwestern.edu> Subject: [Histonet] Permanent/Full Time Histotech Job in Panama City, FL Message-ID: <d58bf7c8.413f4%meli...@alliedsearchpartners.com> Content-Type: text/plain; charset="us-ascii" Hello All, I have a full time/permanent position for a Histotech in Panama City, FL. This is a Monday-Friday Day Shift opportunity and I am looking for a long term permanent candidate. Please let me know if you are interested and I will provide more information. Thank you! Melissa Owens President, Laboratory Staffing Allied Search Partners Direct Line: 407.413.9117 Toll Free: 888.388.7571 ext. 102 F: 888.388.7572 ------------------------------ Message: 3 Date: Thu, 13 Jul 2017 11:43:46 +0000 From: Lester Raff MD <lr...@uropartners.com> To: "Histonet (histonet@lists.utsouthwestern.edu)" <histonet@lists.utsouthwestern.edu> Subject: [Histonet] New Lab Related Blog Post Message-ID: <6347C6D2B080534F9B5C2B08436DCFAF114F70C9@COLOEXCH01.uropartners.local> Content-Type: text/plain; charset="us-ascii" Good morning to all. The rains in Chicago have finally stopped. Link for a lab blog post is below. https://urldefense.proofpoint.com/v2/url?u=http-3A__www.chicagonow.com_downsize-2Dmaybe_2017_07_oops-2Dwe-2Ddid-2Dit-2Dagain-2Danother-2Dresearch-2Dpaper-2Dtells-2Dus-2Dpathologists-2Dsometimes-2Dhave-2Dit-2Dtough-2Dthis-2Dtime-2Dwith-2Dmelanoma_&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=BMnYbAIiXA3i7op2GB24dtCro4-e1ZM2MHR_w-FW3gc&e= Thanks, Lester J. Raff, MD MBA Laboratory Medical Director ------------------------------ Subject: Digest Footer _______________________________________________ Histonet mailing list Histonet@lists.utsouthwestern.edu https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.utsouthwestern.edu_mailman_listinfo_histonet&d=DQICAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=1cLLjC11YCqzLhqVtNKQcyhMt62CI6G4XYiTB8c7xDA&m=kGqc4zz3kX--1rHjY-YoBfcDwuXTr_4WO7sfWADnB6s&s=gVV45__1yJfu6axbr8oxcPYBvFX1MiI_GOD2r2Kpv_g&e= ------------------------------ End of Histonet Digest, Vol 164, Issue 9 ****************************************The information contained in this message and any attachments is intended only for the use of the individual or entity to which it is addressed, and may contain information that is privileged, confidential and exempt from disclosure under applicable law. If you have received this message in error, you are prohibited from copying, distributing or using the information. Please contact the sender immediately by return e-mail and delete the original message. _______________________________________________ Histonet mailing list Histonet@lists.utsouthwestern.edu http://lists.utsouthwestern.edu/mailman/listinfo/histonet