On Tuesday, 09/15/2009 at 09:44 EDT, "Frank M. Ramaekers" 
<framaek...@ailife.com> wrote:

> After 2nd level is brought up:
> 
> From 1st level:
> 
> q 5336-5338
> PRT 5336 ATTACHED TO VM2ND    5336
> PRT 5337 ATTACHED TO VM2ND    5337
> PRT 5338 ATTACHED TO VM2ND    5338
> 
> From 2nd level:
> 
> q 5336-5338
> DEV  5336 OFFLINE , DEV  5337 OFFLINE , DEV  5338 OFFLINE
> Ready; T=0.01/0.01 08:42:24
> vary on 5336-5338
> HCPCPN6895I Device 5336 cannot be varied online because the device
> HCPCPN6895I identification data is inconclusive.
> HCPCPN6785E Unable to identify device 5336 dynamically.
> HCPCPN6895I Device 5337 cannot be varied online because the device
> HCPCPN6895I identification data is inconclusive.
> HCPCPN6785E Unable to identify device 5337 dynamically.
> HCPCPN6895I Device 5338 cannot be varied online because the device
> HCPCPN6895I identification data is inconclusive.
> HCPCPN6785E Unable to identify device 5338 dynamically.
> 3 device(s) specified; 0 device(s) successfully varied online
> Ready(06785); T=0.01/0.01 08:42:46
> 
> I don't see why I can't bring these devices online 2nd level.

I suspect that your 1st level SYSTEM CONFIG has RDEVICE entries that 
define these devices as printers.  Copy those same entries to your 2nd 
level SYSTEM CONFIG.

Alan Altmark
z/VM Development
IBM Endicott