On Tuesday, 09/15/2009 at 10:53 EDT, Florian Bilek 
<florian.bi...@gmail.com> wrote:

> I need to establish several PPRC pairs between two DS-8000 at our local 
site 
> for our z/VM system.
> 
> There is a lot of information around about this matter but unfortunately 
it is 
> still not totally clear to me, if there are native z/VM commands for 
manageing 
> the PPRC pairs or do I need to use ICKDSF to achieve this. 
> Referring to the DUPLEX command I find it ambigous what is stated there 
as it 
> referes to " 3990-3 and 3990-6" controllers only. Would be nice to have 
some 
> reference regarding PPRC, clarifying that this is not for DS-8000 PPRC. 
> 
> I would like to prepare scripts that establish or break the pairing if 
> necessary. 

z/VM does not have CP commands to manage PPRC connections.  You will need 
to do it via ICKDSF.

Alan Altmark
z/VM Development
IBM Endicott

Reply via email to