No, he won't.  But, with CP class A, he can issue SET PRIVCLASS * +S.

You your change is only safe to avoid accidental FORCEs or SHUTDOWNs

2009/11/16 Wandschneider, Scott <scott.wandschnei...@infocrossing.com>

> If I change SHUTDOWN and FORCE with the following:
>  MODIFY COMMAND SHUTDOWN PRIVCLASS S
>  MODIFY COMMAND FORCE    PRIVCLASS S
>
> ...and OPER1 does not have class S but does have class A, can OPER1 still
> successfully issue SHUTDOWN or FORCE?
>
> Thank you,
> Scott R Wandschneider
> Senior Systems Programmer|| Infocrossing, a Wipro Company || 11707 Miracle
> Hills Drive, Omaha, NE, 68154-4457|| : 402.963.8905 || :847.849.7223  ||
>  : scott.wandschnei...@infocrossing.com **Think Green  - Please print
> responsibly**
>
>


-- 
Kris Buelens,
IBM Belgium, VM customer support

Reply via email to