Q1: yes, ignore, LE has some pieces that must reside < 16M Q2: If you don't use the GUI interface to OSASF nor to VMHCD, you don't need these files.
Q1 and Q2 are not related 2010/10/27 George Henke/NYLIC <george_he...@newyorklife.com> > > Even though everything finished successfully when I applied maintenance > yesterday, I received some warnings which prompt the following 2 questions. > I have not PUT2PROD yet. > > *Question 1: Does the restrictive RMODE cause the RO IFREQ message below > and, if so, do I need to rerun this without the RMODE restriction?* > > ************************************************************************ > **** SERVICE USERID: MAINT **** > ************************************************************************ > **** Date: 10/26/10 Time: 18:39:45 **** > ************************************************************************ > WN:DMSLIO994W Restrictive RMODE encountered in CSECT CEEBCKRI. > WN:DMSLIO994W LOAD continues below 16Mb. > RO:VMFAPP2112W PTF UK59535 has a IFREQ requisite for PTF UM33112 in > RO: product 5VMCMS40 (CMS component for z/VM 5.4.0) > > *Question 2: Do I need to copy these objects to the workstation? I don't > think so.* > > WN:VMFBDC2250W The following OSA objects have been built on BUILD0 100 > WN: (K) and should be copied to your workstation: > WN:VMFBDC2250W IOAJAVA BIN > WN:VMFBDC2250W The following VMHCD objects have been built on BUILD0 300 > WN: (I) and should be copied to your workstation: > WN:VMFBDC2250W EEQINSTX EXEBIN > > -- Kris Buelens, IBM Belgium, VM customer support