thanks to all that replied activating the interface, deleting the disable, then re-adding the disable, seemed to fix my issue
christian On Wed, Sep 10, 2008 at 11:31 PM, Christian Koch <[EMAIL PROTECTED]> wrote: > Hi - > > I have an interface on an old M40, which i have 'deactivated', 'set > disable' on that is still alarming Link Down via SNMP polling, and > showing up/down on a show int terse and Enabled on show interface > outputs... > > There is nothing connected on this interface > > Am I missing something? > > Software is JUNOS 7.0R2.7 > > [edit interfaces ge-6/1/0] > # show > ## > ## inactive: interfaces ge-6/1/0 > ## > inactive: disable; > no-traps; > > [edit interfaces ge-6/1/0] > [EMAIL PROTECTED] > [EMAIL PROTECTED]> > [EMAIL PROTECTED]> show interfaces terse | match ge-6/1/0 > ge-6/1/0 up down > > [EMAIL PROTECTED]> show interfaces ge-6/1/0 | match Enabled | last > Physical interface: ge-6/1/0, Enabled, Physical link is Down > > > Thanks! > > Christian > _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp