I see. And as I understand, there is no SNMP OID for "set chassis
alarm services rx-errors", "set chassis alarm ethernet link-down",
"set chassis alarm management-ethernet link-down" etc, but one should
configure the threshold value for those alarms(ignore/red/yellow) and
monitor "yellow alarm" and "red alarm" alerts in NMS(for example
Nagios)? Which means each time for example "red alarm" appears in NMS,
it may have multiple meanings?


regards,
martin

2011/4/5 Masagung Nugroho <masag...@trinetprimasolusi.net>:
> Yellow led is minor alarms
> Red led is major alarms
> When first configuration yellow indicate the rescue configuration is not set
>
> Best Regards,
> -Masagung Nugroho-
>
> -----Original Message-----
> From: juniper-nsp-boun...@puck.nether.net
> [mailto:juniper-nsp-boun...@puck.nether.net] On Behalf Of Ido Szargel
> Sent: Tuesday, April 05, 2011 11:58 AM
> To: Martin T; juniper-nsp@puck.nether.net
> Subject: Re: [j-nsp] "Yellow led" and "Red led" alarms in Juniper
>
> Hi Martin,
>
> You have the "set chassis alarams" stanza where you can play with the
> chassis alarms levels (yellow/red/ignore)
> The most useful thing I use is to turn off the red alarm about the MGMT
> interface not connected to anything on EX switches.
>
> Regards,
> Ido.
>
> -----Original Message-----
> From: juniper-nsp-boun...@puck.nether.net
> [mailto:juniper-nsp-boun...@puck.nether.net] On Behalf Of Martin T
> Sent: Tuesday, April 05, 2011 2:26 AM
> To: juniper-nsp@puck.nether.net
> Subject: [j-nsp] "Yellow led" and "Red led" alarms in Juniper
>
> As far as I know, all Juniper routers have "Yellow led" and "Red led"
> indicators on "craft interface". Few examples:
>
> http://www.juniper.net/techpubs/software/nog/nog-hardware/html/craft-interfa
> cea11.gif
> http://www.juniper.net/techpubs/software/nog/nog-hardware/html/craft-interfa
> cea4.gif
> http://www.juniper.net/techpubs/software/nog/nog-hardware/html/craft-interfa
> cea8.gif
>
> ..and one photo as well:
>
> http://blog.gyron.net/wp-content/uploads/mx240_right_low.png
>
> As I understand, yellow alarms are informative and red ones are critical.
> However, which alarms classify as "Yellow" and which ones classify as "Red"?
> Is there a possibility to change those thresholds?
>
>
> regards,
> martin
> _______________________________________________
> juniper-nsp mailing list juniper-nsp@puck.nether.net
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>
> _______________________________________________
> juniper-nsp mailing list juniper-nsp@puck.nether.net
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>
>
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp