Le 12/05/15 10:27, Mark Tees a écrit :
l2circuit is not supported as that requires a two label stack to work.

EX4200's can only switch a 1 label stack. Any traffic passed in  P/LSR
fashion that has more than 1 label in the stack gets dropped
transparently from what I have seen, regardless of what the control
plane/RE said.

ccc/remote-interface-switch like in the link I sent earlier is the
only way that works as far as I have seen. This is probably because of
the 1:1 mapping of LSP to ccc direction.


Strange, because what I tested on Ex4550 is the opposite :
l2circuit are working, ccc not.

--
Raphael Mazelier
_______________________________________________
juniper-nsp mailing list juniper-nsp@puck.nether.net
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to