Here's my lab MX960 Mine is currently set at 1 second
set services analytics export-profile my-exprt-prfl reporting-rate 1 I tried decimals and zero to see what would happen, seems that 1 is the lowest. {master}[edit] agould@lab-960# set services analytics export-profile my-exprt-prfl reporting-rate Possible completions: <reporting-rate> Telemetry interval in seconds (0..3600 seconds) {master}[edit] agould@lab-960# set services analytics export-profile my-exprt-prfl reporting-rate .1 ^ Invalid numeric value: '.1' at '.1' {master}[edit] agould@lab-960# set services analytics export-profile my-exprt-prfl reporting-rate .9 ^ Invalid numeric value: '.9' at '.9' {master}[edit] agould@lab-960# set services analytics export-profile my-exprt-prfl reporting-rate 0 {master}[edit] agould@lab-960# show | compare [edit services analytics export-profile my-exprt-prfl] - reporting-rate 1; + reporting-rate 0; {master}[edit] agould@lab-960# commit check re0: [edit services analytics] 'sensor my-sensor-14' reporting-rate of 0 not supported for PFE sensor error: configuration check-out failed -Aaron _______________________________________________ juniper-nsp mailing list juniper-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/juniper-nsp