On Mon, Jan 21, 2013 at 10:19 AM, Kyoungil Kim <ki0351....@samsung.com> wrote:
> In dwc manual, the below contents are described.
> "During end of packet, interrupt is not generated if threshold
> programming is larger than any remaining data. It is responsibility
> of host to read remaining bytes on seeing Data Transfer Done
> interrupt"
> We also have seen the data cannot be read fully
> when "sg_miter->length" is less than FIFO size.
>
> Signed-off-by: Kyoungil Kim <ki0351....@samsung.com>
> Signed-off-by: Seungwon Jeon <tgih....@samsung.com>
> ---
>  drivers/mmc/host/dw_mmc.c |   11 +++++++----
>  1 files changed, 7 insertions(+), 4 deletions(-)
>
> diff --git a/drivers/mmc/host/dw_mmc.c b/drivers/mmc/host/dw_mmc.c
> index 323c502..afcc0f4 100644
> --- a/drivers/mmc/host/dw_mmc.c
> +++ b/drivers/mmc/host/dw_mmc.c
> @@ -1430,7 +1430,7 @@ static void dw_mci_pull_data(struct dw_mci *host, void 
> *buf, int cnt)
>         host->pull_data(host, buf, cnt);
>  }
>
> -static void dw_mci_read_data_pio(struct dw_mci *host)
> +static void dw_mci_read_data_pio(struct dw_mci *host, u8 int_data_over)

The data_over argument should probably be a bool.
--
To unsubscribe from this list: send the line "unsubscribe linux-mmc" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html